Download Earthwise Technologies CZ?1000F Product data
Transcript
Public Works and Government Services Canada Travaux publics et Services gouvernementaux Canada 1 1 RETURN BIDS TO: RETOURNER LES SOUMISSIONS À: Title - Sujet Bid Receiving - PWGSC / Réception des soumissions - TPSGC 11 Laurier St. / 11, rue Laurier Place du Portage , Phase III Core 0B2 / Noyau 0B2 Gatineau Québec K1A 0S5 Bid Fax: (819) 997-9776 Solicitation No. - N° de l'invitation Amendment No. - N° modif. EP168-151179/A 001 Client Reference No. - N° de référence du client Date 20151179 2015-01-09 SOLICITATION AMENDMENT MODIFICATION DE L'INVITATION The referenced document is hereby revised; unless otherwise indicated, all other terms and conditions of the Solicitation remain the same. Ce document est par la présente révisé; sauf indication contraire, les modalités de l'invitation demeurent les mêmes. MODIFICAT. TO DAM STOPLOG LIFTERS GETS Reference No. - N° de référence de SEAG PW-$$ML-044-24843 File No. - N° de dossier CCC No./N° CCC - FMS No./N° VME 044ml.EP168-151179 Solicitation Closes - L'invitation prend fin at - à 02:00 PM on - le 2015-01-27 F.O.B. - F.A.B. Plant-Usine: Destination: Time Zone Fuseau horaire Eastern Standard Time EST Other-Autre: Address Enquiries to: - Adresser toutes questions à: Buyer Id - Id de l'acheteur Aussant, Marc 044ml Telephone No. - N° de téléphone FAX No. - N° de FAX (819) 934-1386 ( (819) 956-0897 ) Destination - of Goods, Services, and Construction: Destination - des biens, services et construction: Comments - Commentaires Vendor/Firm Name and Address Raison sociale et adresse du fournisseur/de l'entrepreneur Complexe des barrages Timiskaming 141 route 63 (Sault Island) Thorne Ontario P0H 2J0 Instructions: See Herein Instructions: Voir aux présentes Delivery Required - Livraison exigée Delivery Offered - Livraison proposée Vendor/Firm Name and Address Raison sociale et adresse du fournisseur/de l'entrepreneur Issuing Office - Bureau de distribution Marine Machinery and Services / Machineries et services maritimes 11 Laurier St. / 11, rue Laurier 6C2, Place du Portage Gatineau Québec K1A 0S5 Telephone No. - N° de téléphone Facsimile No. - N° de télécopieur Name and title of person authorized to sign on behalf of Vendor/Firm (type or print) Nom et titre de la personne autorisée à signer au nom du fournisseur/ de l'entrepreneur (taper ou écrire en caractères d'imprimerie) Signature Canada Page 1 of - de 2 Date Solicitation No. - N° de l'invitation Amd. No. - N° de la modif. Buyer ID - Id de l'acheteur EP168-151179/A 001 044ml Client Ref. No. - N° de réf. du client File No. - N° du dossier CCC No./N° CCC - FMS No/ N° VME 20151179 044mlEP168-151179 This solicitation amendment 001 is raised to provide this question and answer set 1. Bidders are advised that due to technical problems with the conference call of January 7 that they should submit all questions in writing to marc.aussant@tpsgc-pwgsc.gc.ca with cc to dianne.tinkess@tpsgc-pwgsc.gc.ca Question and Answer Set 1. Q1. The single line electrical drawing on page 46 is difficult to read. Please provide a better version. A1. The PDF file is too large to post to BuyAndSell. Interested bidders should provide their email address to marc.aussant@tpsgc-pwgsc.gc.ca with cc to dianne.tinkess@tpsgc-pwgsc.gc.ca to receive a copy of the PDF Drawing. Q2. Are there electrical as-built drawings for the existing machine that could assist with the design work of Task 2? A2. Yes, there are electrical drawings, but the PDF files are too large to post to BuyAndSell. Interested bidders should provide their email address to marc.aussant@tpsgc-pwgsc.gc.ca with cc to dianne.tinkess@tpsgc-pwgsc.gc.ca to receive copies. Q3. Does Task 5 include any electrical work? A3. No, there is no electrical work in this Task. The work of Task 5 is only to design, fabricate, and install an extension bracket to the existing steel support for the cable—see Figure 17. Q4. For the work of Task 3, would it be acceptable to mount a heater under the electrical panel near the door (i.e. behind the fan shown in Figure 10 on page 39). A4. Yes, this is acceptable. Q5. Please provide additional information on the existing heater. A5. Product data is attached to this amendment. Page 2 of - de 2 bearthwise.com Customer/WarrantyService: (866)446Ǧ2864 18324CookRoad,Suite6 Yelm,Washington98597 Technologies,Inc EarthWise NorthAmericanDistributionandSales CZ Infrared Heaters Green Technology for a Modern World CZ Infrared by EarthWise ™ Notice: This unit requires a conventional lowǦ voltage thermostat to be supplied by the customer. A low voltage thermostat, such as a Honeywell ModelCT8775,orRTH5100,orequivalentmustbe installedinconjunctionwiththisunit. Includes: ApplicationGuidelines InstallationGuidelines UserInformation&Guidelines OperatingInstructions Warranty&Servicing Save these instructions ModelsCZǦ1000F/ModelCZǦ500F FlushMountingSeries Therapeuticinfraredheatingsystemsforagreen,healthyenvironment CZ Infrared™ Owner’s Manual CZ Infrared™ by EarthWise. Feel the Difference. Earthwise Technologies,Inc CZInfrared™CeramicInfraredInǦWallHeater CZǦ1000F (FlushMounting) Customer/Warranty Service: (800) 595-9605 Page 1 ©2009 EarthWise Technologies, Inc Formoreinformation,orforadditionalassistance,pleasecallorwrite: EarthWiseTechnologies,Inc. 18324CookRoad,Suite6 Yelm,Washington98597 Customer/WarrantyService:(800)595Ǧ9605 Toobtainwarrantyservice,youmust: 1. ProvideproofofpurchaseintheformofaBillofSaleorreceiptedinvoice toshowevidencethattheunitiswithinthewarrantyperiodorvalidserial numbertodocumentmanufacturedate,whicheveristheformerdatewill behonoredbyEarthWiseTechnologiesinlieuofproofofpurchase. 2. Contact the Dealer you purchased your equipment from for additional instruction. WarrantyClaimProcedure ThiswarrantyisinvalidifthefactoryǦappliedserialnumberhasbeenalteredor removedfromtheproduct. WarrantyRestriction The Company will not be responsible for the damages or losses, direct or indirect, caused by misuse, abuse, accident, negligence, conditions of transportation or storage, or failure to follow instructions. The Company will notberesponsibleforanystatementsthataremadeorpublished,writtenor oral,thatareinconsistentwiththiswrittenwarranty,orwhicharemisleading orinconsistentwiththefactsaspublishedintheliteratureorspecificationsby theCompany. Warranty & Service Information (continued) Page 22 Customer/Warranty Service: (800) 595-9605 Some jurisdictions do not allow the exclusion of limitation of incidental or consequentialdamages,sotheabovelimitationorexclusionmaynotapplyto you. ALL WARRANTIES IMPLIED BY LAW, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSLY LIMITED TO THE DURATION OF THE WARRANTY SET FORTH ABOVE. Some jurisdictions do not allow limitations on the length of the implied warranty,sotheabovelimitationmaynotapplytoyou. IN NO EVENT SHALL EWT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES, LOSS OF PROFIT, OR MEDICAL EXPENSES CAUSED BY ANY DEFECT, FAILURE, MISUSE, OR MALFUNCTION OF THE PRODUCT. Limitations EarthWise Technologies, Inc (EWT) warrants this product, to the original purchaser or gift recipient, to be free from defects in workmanship and materials under normal use and service, for a period of three years from the dateofpurchase.EWTfurtherwarrantstheinfraredheatingelements,tothe original purchaser or gift recipient, for a period of two additional years from thedateofpurchase. Shipping:EWTshallbearthecostofreturnshippingandrepair,orreplacement if, during the first 90 days, there is a defect in workmanship or materials. Thereafter, customer shall bear the cost of return shipping and EWT shall repairorreplaceanydefectivepartincludingalllaborforaperiodofonefull yearfromthedateofpurchase. Extended infrared element warranty: For an additional twoǦyear period, EWT shall warrant the infrared elements in the heater to be free from defects in workmanshipandmaterialsundernormaluseandservice,andshallsupplyat no cost to the original purchaser replacement elements as required to maintainproductingoodworkingorder. FiveǦYearLimitedWarranty Warranty & Service Information Page 21 15 16 Maintenance Troubleshooting ©2009 EarthWise Technologies, Inc 21 15 OperatingInstructions Warranty&ServiceInformation 15 ForBestPerformance 20 15 ForYourSafety/Warning DiagramofCZInfrared™HeaterCZǦ500F 13 Wiring/ThermostatInstructions&Diagram 19 8 InstallationInstructions DiagramofCZInfrared™HeaterCZǦ1000F 7 HowManyUnitsdoINeed? 18 7 InstallationGuidelines CZInfrared™HeaterSpecifications—CZǦ500F 7 UnpackingYourNewCZInfrared™Heater 17 4 EnergySavingBenefits CZInfrared™HeaterSpecifications—CZǦ1000F 3 3 ComfortLevels&TherapeuticBenefits WhyUseCZInfrared™InfraredHeat Table of Contents Page 2 Customer/Warranty Service: (800) 595-9605 Withtheintentofeconomizingandsavingonbuildingcosts,mostcontractors will combine the heat & air conditioning ducts into one distribution system. ThismakesthecrossǦcontaminationissuethoughtheairconditioningductsa potentialhealthproblem,especiallyforthosewithrespiratorysensitivitiesand allergies,includingasthma. Thenatureoftheinfraredwaveissuchthatitrequireslocalizedgenerationof the infrared wave in order to optimizetheefficiencyandsavingsproduced by using an infrared heating source. This design advantage eliminatestheneed CZInfrared™heatingsystemsaretheultimateingreentechnologyengineering –affordabletopurchaseandeconomicaltooperate–exceptionallyeconomical, extremelyquiet,theyproducecomfortable,healthy,therapeuticinfraredheat. Theyareeasytoinstall,andtheylookgreatonyourwall. CZInfrared™heating systems sterilize the air that is processed through them making them a sanitarysourceofheatforthosesufferingfromrespiratoryconditions. CZInfrared™heatstheroomevenlyfromfloortoceiling.HomesandOffices with high ceilings are not affected by the difference in heat displacement between thefloor and ceiling. In other words, the temperature on the floor andtheceilingremainsthesamewithoutanysupplementalfancirculationto keepthetemperaturebalancedthroughouttheroom. Thecomfortlevelsachievedwhenusinginfraredheataresuperiortothoseof radiant heating systems. Infrared heat warmsthebodyfaster so the energy that flows into the body is greater than when being absorbed from conventional radiant heating sources. Room temperatures of 68°F with infrared feel like 72°F with conventional heating sources so you can set the thermostatback4Ǧ5degreesandexperiencethesamecomfortlevelsutilizing lessenergytokeepyouwarmandcozy. ComfortLevels&TherapeuticBenefitsofInfraredHeat Infrared heat, by virtue of its shorter wave length, is able to penetrate solid objects faster than radiant heat. The advantages of infrared heat have been utilized for years as a therapeutic treatment for cardiovascular and general circulationproblems. WhatIsInfraredHeat&Howdoesitwork? Why Use CZ Infrared™ Infrared Heating Page 3 A B C D E F G H I J K FrontCover Case Fan CeramicIRHeatingElement FanCase CopperAirGuide BottomAirGuide FanTransformer Solidstaterelay HighHeatSensor FanSensor PartsList ConnectionPlate IRandSensorCaseBottom MountingBracket InsideInsulatorCover Insulator OutsideInsulatorCover ElectricalComponentsDivider BottomCover Grill IRandSensorCaseTop RomaxWiringbox IRRetainingclip Rearbaffleassembly ©2009 EarthWise Technologies, Inc L M N O P Q R S T U V W X Diagram of CZ Infrared™ Heater CZ-500F Page 20 Cover Case HeaterCore Grill FanHolder Fans InsulatorCover HighLimitReset TopCaseBracket J K L M N O P BottomCaseBracket CeramicHeatingElement FanTransformer Baffle HeatResistantInsert Solidstaterelay ConnectionPlate Customer/Warranty Service: (800) 595-9605 A B C D E F G H I PartsList Diagram of CZ Infrared™ Heater CZ-1000F Page 19 ©2009 EarthWise Technologies, Inc Thenatureoftheinfraredwaveallowstheheatertobeinstalledhigheronthe wall than conventional inǦwall heater systems without compromising the transferoftheheattothefloor.Theadvantageofthehigherinstallationon thewallguaranteesthatfurnitureandotherobstructionstotheairflowfrom theheaterareeliminated.Childtamperingisalsoeliminated. Evendistributionoftheinfraredwaveisalsoassuredsincetheairspaceabove the furniture is virtually unrestricted. When conventional heat sources are vented through the ceiling to economics and save onconstruction costs, the heatremainsontheceilingandmustbepushedtofloorwithceilingfans.This isnotrequiredwithinfraredheat. BetterHeatDistribution CZ Infrared™ heating systems operate virtually silently at over 150 cubic feet perminuteperheatingunit.Theyarequieterthanforcedairsystemsandthey donothavethetypicalcrackingandpoppingexperiencedwhenheatingwith baseboard heaters. Compared to conventional inǦwall heaters there is no comparison to the quiet operation of the CZ Infrared™ fan system. Fans are ratedat16dBcomparedto65dBofconventionalinǦwallheatingsystems. QuietOperation Infraredheatwavesaretransferredmorequicklythroughouttheroomdueto theirshorterwavelength.Theresultsareimpressivebecauseitrequiresless energy to heat the room evenly with infrared heat than with radiant heating sources. This makes infrared heat a highly costǦefficient solution for heating yourhome. Ifyoureallywanttosaveonenergycosts,thecostofheatingwithCZInfrared™ heatisgoingtobespectacular.Usuallya50%savingsoverconventionalheat sources is achieved, even with other electrically generated heating systems. Asmuchas65%savingsisachievedifreplacingheatingoilorotherfossilfuel heatingsystems. EnergySavingBenefits EnergySavingBenefits forductwork to distribute the heat through the various rooms of a home or office.Eliminatingtheductworkalsoeliminatesthedustpollenandmoldthat accumulatesinaconventionalheatductsystem. Page 4 Customer/Warranty Service: (800) 595-9605 CZ Infrared™ heaters contain a proprietary highǦefficiency, ceramic infrared emitter(orheatingelement)whichproducesmoreinfraredheatperkilowatt thanconventionalceramic.quartz,orcarbonplates. PatentedProprietaryTechnology The CZ Infrared™ heater service panel and wall registers are stylish and functionalwithamodestdesignflaremakingthemmorefavorableforcustomǦ homeinstallationthanconventionalregistersandintakeducts.Thedesigner panel on the wall register can be left white or custom painted to match or contrastthewalls. Stylish&Functional *ComponentsintheCZInfrared™heatingsystemaredesignedtolast10times longerthanotherinǦwallheaters.CZInfrared™warrantycoverageandservice proceduresaresimpletofollowandtheycanbeservicedintenminutesorless shouldrepairberequired. * The cost topurchase andinstall a CZ Infrared™ infrared heating system for yourentirehomeisusuallymuchcheaperthanthecostofinstallingacentral forcedairheatingsystem. CostǦEffectivetoInstall The CZ Infrared™ heating system utilizes state of the art electronics and internalpowersourcingtoacceptalowǦvoltagethermostatofyourchoosing. Lowvoltagewallthermostatsprovidemoreaccuratetemperaturecontroland canbelinkedtoacentralcontrolsystemifdesired. The unique lowǦvoltage thermostat controls on a CZ Infrared™ heater allow theheatertobelinkedtoacentralzonedcontrolsystemwithoutmodification or special switching devices to control the voltage to the heating elements themselves.ThisfeatureallowstheCZInfrared™systemtobeoperatedinthe most economical manner possible by utilizing the infrared heat only in those spaces which are currently being occupied and require the heat. Zoned heating is as much as 50% more economical to use when the entire home or officedoesnotrequireheatinallareas100%ofthetime.Thecostsavingsfrom thisfeaturealonemakesinitialinstallationoftheCZInfrared™heatingsystem payforitselfinamatterofmonths. AccurateTemperatureRegulation Page 5 x x x x x x x x x x x x x x x x x x x x x x x ©2009 EarthWise Technologies, Inc Warranty:Limited3YearP&L.5Year—ceramicemitters. FanNoiseLevel:18dB—practicallysilent. FrequencyHum:ThereisnoAC60HzfrequencyhumaswithotherinǦwallsystems. FanSystem:One(1)highvolume,lownoise90mmDCfan. HeatOutput:2,800BTUinfraredheat. CeramicLifeExpectancy:Ratedat40,000hours. HeatingElements:One(1)ceramicinfraredemitter500w. HeatChambercopperlinedformaximumiontransfer. HeatType:TherapeuticfarǦinfraredheat. Installation:Anywallwithaminimum3½inchesofdepth. ListedApprovals:CTUVǦUS&International(ULEquivalent). SafetyCutǦOff:Yes. CZ-500F ZonedHeatCapability:PreǦwired.SimpletwoǦwirecontactto anyzonecontrolpanel—canalsoacceptmultipleparallelhookǦupstoasinglelowǦ voltagethermostat. ThermostatType:Any12Ǧ24voltlowǦvoltagethermostat(not supplied). ThermostatPowerRequirement:None.Theunitcontainsits ownlowvoltagepowersupplyforthermostatoperation. LifeExpectancy:CZInfraredheaters—25years+. InternalceramicblanketprovidesR45insulationbetweenthe wallandtheheater.Theheatercabinetinstalledinthewall remainscooltothetouchwhiledeliveringwarm(160°F) infraredheatintotheroom. ChassisSafetyInsulation:Exceedsallgovernmentand independentlaboratorystandardsforsafetyinaninstalled heatingappliance(asafetystandardthatexceedsother manufacturer’sspecifications). PowerSupply:Requiresisolated12gaugewiretofusepanel. PowerRequirements:120VoltAC—500Watt. Dimensions:18”x43/8”x4”(H,W,D) Weight:8.0lbs Cabinet:AllMetal–22&24gauge ModelCZǦ500F CZ Infrared™ Heater Specifications Page 18 Warranty:Limited3YearP&L.5Year—ceramicemitters. FanNoiseLevel:18dB—practicallysilent. FrequencyHum:ThereisnoAC60HzfrequencyhumaswithotherinǦwallsystems. FanSystem:Three(3)highvolume,lownoise90mmDCfans. HeatOutput:4,800BTUinfraredheat. CeramicLifeExpectancy:Ratedat40,000hours. HeatingElements:Two(2)ceramicinfraredemitters500w.,500w. HeatChambercopperlinedformaximumiontransfer. HeatType:TherapeuticfarǦinfraredheat. Installation:Anywallwithaminimum3½inchesofdepth. ListedApprovals:CTUVǦUS&International(ULEquivalent). SafetyCutǦOff:Yes. ZonedHeatCapability:PreǦwired.SimpletwoǦwirecontacttoanyzonecontrol panel—canalsoacceptmultipleparallelhookǦupstoasinglelowǦvoltage thermostat. ThermostatType:Any12Ǧ24voltlowǦvoltagethermostat(notsupplied). ThermostatPowerRequirement:None.Theunitcontainsitsownlowvoltage powersupplyforthermostatoperation. LifeExpectancy:CZInfraredheaters—25years+. InternalceramicblanketprovidesR45insulation CZ-1000F betweenthewallandtheheater.Theheatercabinet installedinthewallremainscooltothetouchwhiledeliveringwarm(160°F) infraredheatintotheroom. ChassisSafetyInsulation:Exceedsallgovernment andindependentlaboratorystandardsforsafety inaninstalledheatingappliance(asafetystandard thatexceedsothermanufacturer’sspecifications). PowerSupply:Requiresisolated12gaugewireto fusepanel. PowerRequirements:120VoltAC—1000Watt. Customer/Warranty Service: (800) 595-9605 x x x x x x x x x x x x x x x x x x 5 Dimensions:16”x12 /8”x4”(H,W,D) Weight:13.0lbs Cabinet:AllMetal–22&24gauge CZǦ1000FǦ1000watts CZǦ500FǦ500watts ©2009 EarthWise Technologies, Inc CZ Infrared™ heating systems come with CǦTUVǦUS certifications with equivalentapprovalsbothinULandCSAclassifications.CZInfrared™heaters aremanufacturedinTaiwanandChinabyEarthWiseElectronics,Inc. QualityAssurance CZInfrared™heatingsystemscomein120voltunitsfornewconstruction.The 120voltunitsaredesignedtoberetrofittedtoexistinginstallationswhereonly 120voltcircuitryisavailable. CZ Infrared™ heaters come in two sizes: 1000 watts for conventional room heatingand500wattsforbathrooms,hallwaysandclosets. FlexibleSize&VoltageApplications x x x x x ModelCZǦ1000F Patentpendingcoverageofmorethan30distinctfeaturesintheCZInfrared™ heater are what makes the CZ Infrared™ technology a truly unique energy efficientheatsourceforyourhomeoroffice. Page 6 CZ Infrared™ Heater Specifications Page 17 Customer/Warranty Service: (800) 595-9605 Notes:Calculate4Ǧ6hoursofrunningtimeperdayperheaterinstalledtocalculateBtu’s andelectricalenergycost.Also,rememberthatmultipleunitinstallationsinlargerrooms canbecoupledtothesamelowǦvoltagethermostatorregulatedseparately. Whendeterminingtherightnumberofunitstoinstallinaconventionalhome, thefollowingitemsneedtobetakenintoconsideration: x Theinsulationfactor,andwindowsize&placement x Themeanoutsidetemperatureduringthecoldestdaysoftheyear x Thesizeofeachroom x Theoverallsizeofthehome x Thenumberoffloorsinvolved x TheEntranceandEgresspoints In lieu of overall engineering calculations and thermal loss calculations, a generalruleofthumbcanbeappliedtodeterminethenumberofunitstobe installed: HowManyUnitsDoINeed? Installation Guidelines 5. Ifnoobviousdamageisvisible,proceedwiththeinstallationinstructions asoutlineintheInstallationGuidelinesincludedwiththismanual. 4. Inspecttheunittomakesurethattherearenocrackintheblackceramic heatingelements. 3. Removetheprotectivepackagingmaterialsfromtheinsideoftheheater’s heat exchanger, making sure that all combustible materials have been removedfromaroundtheblackceramicheatingelements. 2. Removetheprotectivepackagingmaterialsfromtheoutsideoftheheater cabinetandfromthefrontfacepanel. Mostlikelyoneoftheceramicelementsis burnt out or the connection to the element is bad. Call a service technician to determine the cause of the problem and if necessary replace the defective ceramicplate. First, push the reset button. Next, check thethermostatleads&listentodetermine if the first fan is operating. If so, call a servicetechnicianforinstallationofanew heatrelay. Heaterdoesn’tappeartobe gettinghotenough HeaterdoesnotheatǦup ©2009 EarthWise Technologies, Inc Mostlikelyyouhaveadefectivefanrelay. Callaservicetechnicianforinstallation. First,pushtheresetbutton.Next,check thethermostatleads.Shorttheleadsout andiftheheaterturnsonyouhavea defectivethermostat,otherwiseyouhave adefectiverelayintheheater. Callaservicetechnicianforinstallationof anewrelay. Checkforobstructionstothefanblades. Iftherearenone,youhaveadefectivefan andmustfirstisolatethedefectivefan unitforreplacement. Callaservicetechnicianforinstallation. Page 16 Heaterfanremainsrunningafter 20minutesofshutǦdown Heaterwon’tturnon Heaterisnoisy Problem 1. FIRST,inspectthepackageforanyobviousdamage. Solution Troubleshooting Your CZ Infrared™ Unpacking Your New CZ Infrared™ Heater Page 7 Customer/Warranty Service: (800) 595-9605 Routinelyinspecttheairregistersontheinfraredunittomakesurethatthereisnodust accumulation.Vacuumasyouwouldanyconventionalheatorairconditioningduct. Itissuggestedthatanannualdustingoftheceramicplatesbeperformedinorderto eliminateanyresidualaccumulationofdustduringthesummermonths.Otherthan this,therearenomaintenancerequirementsinvolved.Inordertoaccomplishthis,the frontplasticpanelmustberemovedbyremovingthefourscrewsandliftingupto releasethepanelfromthetopclip. Maintenance TheunitsareselfǦregulating.TemperatureiscontrolledviaalowǦvoltagethermostat locatedpreferablyontheoppositewallfromtheheatingunit.Theheaterfanswillturn onwhenthepowertotheinfraredheatingelementsturnon.Aftertheheating elementshavecomeuptofulltemperature,athirdfanwillturnontoincreasethe airflowintotheroom.Thisthirdfanwillremainrunningevenaftertheheating elementshavebeenshutdownbythethermostat,inordertodistributetheremaining heatintheheatingelementsintotheroom. Temperaturescanberegulatedfromacentralcontrol(soldseparately)ortheheating unitscanalsobeindependentlyturnonorofffromaremotelocationviaacentralon/ offswitchforeachunit.TheswitchisconnectedbetweenthelowǦvoltagethermostat controlandoneoftheleadwirestothethermostatfromthethermostatcontactonthe heater. Operating Instructions Itisrecommendedthattheairflowpatternintheroombecomescircular.Thisis accomplishedbymountingtheheatertoonesideoftheroom,aspertheillustration,in ordertocreateacircularflowaroundtheroom. Wheremultipleunitsareinstalledinlargerrooms,thiscircularpatterncanbe maintainedbypositioningtheunitstocomplementtheairflows.Thisisaccomplished bypositioningtheminoppositecornersoftheroom. For Best Performance Donotplaceobjectsinfrontofinfraredwallunitsthathavebeenmountedlowerthan thoseparameterssuggestedintheinstallationinstructions.Doingsowillcausetheunit tooverheat,whichwilltriggerthehightemperaturelimitswitch,resultinginapotential servicecalltoreset/replacetheswitch. For Your Safety/Warning Page 15 Roomsizebelow250sq.feet:1Ǧ1000wattunit Roomsizeabove250+to500sq.feet:2Ǧ1000wattunits Roomsizeabove500+to750sq.feet:3Ǧ1000wattunits Roomsizeabove750+to1000sq.feet:4Ǧ1000wattunits Roomsizeabove1000+to1250sq.feet:5Ǧ1000wattunits Roomsizebelow200sq.feet:1Ǧ1000wattunit Roomsizeabove200+to400sq.feet:2Ǧ1000wattunits Roomsizeabove400+to600sq.feet:3Ǧ1000wattunits Roomsizeabove600+to800sq.feet:4Ǧ1000wattunits Roomsizeabove800+to1000sq.feet:5Ǧ1000wattunits Roomsizeabove1000+to1200sq.feet:6Ǧ1000wattunits ©2009 EarthWise Technologies, Inc Requiredoutletopening:TheheatercutǦoutmusthaveaminimalsizeof12.5in. Wx16in.Hx3.5in.Dinordertoaccommodatetheheater. MountingtheHeater Theheatercomeswithtwosetsofmountingbrackets.Usingtheappropriate setofbracketsforthemountingconditions,attachtheheaterunittothewall preferably 6 ft. above the floor to eliminate obstructions to air flow. The heatercanbemountedlowerifpreferred.Thehigherlocationoftheheater alsoinsuresthatobstaclesintheroomsuchasfurniturewillnotencumberthe circulationoftheinfraredheatwavesbeinggeneratedfromtheheater.This assuresevenheatdistributionandpreventscoldǦpocketsofair.Theinfrared heatwillflowevenlyfromfloortoceilingsothelocationoftheheateronthe wallisnotpreǦemptedbynormalinǦwallheaterconsiderations. Note:EachCZInfrared™heatercomeswithtwosetsofmountingbrackets.One setisformountingtheunitpriortosheetrockinstallation,andthesecondsetis formountingtheunitaftersheetrockinstallation,asinthecaseofaremodel. InstallationInstructionsfor1000wattunit HallwaysandNooks:1Ǧ500wattunitper100sq.feet ClosetsandBathrooms:1Ǧ500wattunitper100sq.feet Newconstruction(coldestdaybelow5degrees) &allremodels,standardinsulation: Newconstruction(coldestdayabove5degrees), standardinsulation,onewindowperroom: Page 8 Customer/Warranty Service: (800) 595-9605 Usethenewconstructionbracketsasshown.Attachtheheaterunittothe wall,6ft.(1.8m)orhigherabovethefloortothebottomoftheheaterunit. Thehigherthebetter.Thehigherlocationoftheheaterinsuresthatobstacles intheroomsuchasfurniturewillnotencumberthecirculationoftheinfrared heatwavesbeinggeneratedfromtheheater.Thisassuresevenheat distributionandpreventscoldǦpocketsofair. Usethefollowing mountingbrackets forheaterinstallation priortosheetrock installation. HeatermustnotbelocatedimmediatelybelowasocketǦoutlet. OPTIONAL SITE OPTIMAL SITE CZǦ1000FNewConstructionInstallation Mounting Guidelines (CZ-1000F) Page 9 BLUE RED WHITE CZǦ1000FWiringSchematic WHITE BLUE RED ©2009 EarthWise Technologies, Inc CZǦ500FWiringSchematic *Switchmustbehavingacontactseparationinallpolesthatprovidefulldisconnectionwitha contactseparationofatleast3mmandrated10Aminimum. * Wiring Diagrams Page 14 Customer/Warranty Service: (800) 595-9605 ThermostatWiring Use any conventional thermostat or doorbell wire to route the thermostat to the heater. Unless the thermostat is diode protected or voltage sensitive to DC (positive and negative),it doesn’t matter which heaterthermostat wire goesto the respective contactsonthebackofthermostat. Consultthewiringinstructionsthatareincludedwiththethermostattomakesurethat the low voltage thermostat being used is compatible with the 12 volt DC voltage originating from the yellow and white thermostat wires from the heater. The thermostatshouldbelocatedatleast5feetfromthelocationoftheinǦwallheater. Thefiguresbelowdepictatypicalwiringprocedureusingconventional12/2wireonalargeheater. Theheatercutout shouldhavea minimalsizeof 161/2(h)x123/4(w). Page 10 ©2009 EarthWise Technologies, Inc Use the retrofit brackets as shown. Attach the heater unit to the wall, 6 ft. (1.8m)orhigherabovethefloortothebottomoftheheaterunit.Thehigher thebetter.Thehigherlocationoftheheaterinsuresthatobstaclesintheroom suchasfurniturewillnotencumberthecirculationoftheinfraredheatwaves being generated from the heater. This assures even heat distribution and preventscoldǦpocketsofair. Usethefollowing mountingbrackets forheaterinstallation inexistingconstruction. OPTIONAL SITE OPTIMAL SITE CZǦ1000FExistingConstructionInstallation HeaterWiring Regardlessofthemodelchosen,thereare5wiresinsidethebaseoftheheaterwhich mustbewiredcorrectly.Threewirecontactsarerequiredtoobtainthepowersource. Thewiringcodeisthesamefor120voltunits. Theheatermustbeprovideddisconnectdevice(switch/breaker)fromthesupplymains having a contact separationinall poles that provide full disconnection witha contact separationofatleast3mm. OnthelargeinǦwallunittheblackishot,theredisneutral,andthegreenisground.On the small inǦwall unit the black is hot, the blue is neutral andthe green is ground. On bothunitstheyellowandwhitewiresgodirectlytothethermostat. Noexternalpowersupplyisneeded.Anyattempttoattachanexternalpowersupply willcausedamagetotheinternalcomponentsandwillresultinproductfailure. Whenconnectingmultipleunitstoasinglethermostat,theunitsmustbeconnectedin parallel with all yellow and all white wire leads connected to their same respective terminalsonthethermostat. Failuretofollowtheseguidelineswillresultininternaltransformerfailureandproduct failure. Mounting Guidelines (CZ-1000F) Installation Guidelines (continued) Page 13 Customer/Warranty Service: (800) 595-9605 Usethefollowing mountingbrackets forheaterinstallation priortosheetrock installation. Usethenewconstructionbracketsasshown.Attachtheheaterunittothe wall,6ft.(1.8m)orhigherabovethefloortothebottomoftheheaterunit. Thehigherthebetter.Thehigherlocationoftheheaterinsuresthatobstacles intheroomsuchasfurniturewillnotencumberthecirculationoftheinfrared heatwavesbeinggeneratedfromtheheater.Thisassuresevenheat distributionandpreventscoldǦpocketsofair. Theheatercutout shouldhavea minimalsizeof18 1 /2(h)x47/8(w). Page 12 ©2009 EarthWise Technologies, Inc Usetheretrofitbracketsasshown.Attachtheheaterunittothewall,6ft. (1.8m)orhigherabovethefloortothebottomoftheheaterunit.Thehigher thebetter.Thehigherlocationoftheheaterinsuresthatobstaclesintheroom suchasfurniturewillnotencumberthecirculationoftheinfraredheatwaves beinggeneratedfromtheheater.Thisassuresevenheatdistributionand preventscoldǦpocketsofair. Usethefollowing mountingbracketsfor heaterinstallationin existingconstruction. CZǦ500FExistingConstructionInstallation CZǦ500FNewConstructionInstallation HeatermustnotbelocatedimmediatelybelowasocketǦoutlet. Theheateristobeinstalledsothatswitchesandothercontrolscannotbe touchedbyapersoninthebathorshower. Mounting Guidelines (CZ-500F) Mounting Guidelines (CZ-500F) Page 11