Download Operating principle of the control panel
Transcript
C 20 Operating principle of the control panel General Control keys If a key (sensing switch) is depressed when its function is not available or it has no effect, a brief audio signal is emitted. ■ The LED indicator is ON when the control key is activated (ex.: Sniffer ON). SNIFFER The LED indicator is OFF when the control key is deactivated (ex.: Sniffer OFF). SNIFFER AUTO CAL SNIFFER ZERO GB 01361 - Edition 01 - December 01 ASM 182 TD+ CYCLE AUTO CAL MUTE CYCLE SNIFFER ASM 192 T2D+ Alcatel Vacuum Technology France - ASM 182 TD+ - ASM 192 T2D+ User’s Manual 1/4 C 20 Operating principle of the control panel Menu selection access keys mbar.l/s Pa.m3/s F1 F2 LEAK RATE F3 F4 10 -3 10 -2 10 -1 NEXT SET POINTS SPECTRO + 1 10 -8 10 -9 10 1 10 2 INLET PRESSURE RESET MAINTENANCE Torr.l/s COR 10 -12 10 -11 10 -10 OTHER AUTO CAL SNIFFER 10 -7 10 -6 10 3 mbar hPa Torr 10 -5 STDBY 10 -4 10 -3 EVAC 10 -2 TEST ZERO CYCLE SET POINTS ASM 182 TD+ F1 10 -3 10 -2 10 -1 Pa SPECTRO 10 -5 10 -4 10 -3 F2 MUTE CYCLE SNIFFER MAINTENANCE OTHER Menu selection access keys F3 F4 mbar AUTO CAL SPECTRO NEXT SET POINTS SPECTRO + MAINTENANCE RESET OTHER ASM 192 T2D+ Pressing the corresponding Menu selection key a second time deactivates the menu. The LED indicator is then turned OFF and the previous screen is displayed again. 2/4 SET POINTS SET POINTS Alcatel Vacuum Technology France - ASM 182 TD+ - ASM 192 T2D+ User’s Manual GB 01361 - Edition 01 - December 01 The LED indicator comes ON after depressing the key. It activates the menu. Then the corresponding menu is shown on the alphanumeric display. C 20 Operating principle of the control panel Parameter function keys F1 There are up to four function keys available on the alphanumeric display (F1, F2, F3 and F4). One parameter key per line can be changed at a time. F2 F3 F4 The LED indicator is ON when the corresponding function key is available: the modification of the parameter displayed on the line is authorized. F1 Press the function key: the LED indicator will flash: the modifications changes can be F1 performed. It is possible to escape and reset the previous value by pressing RESET key or the active menu selection key. Once the parameter is modified, pressing the function key again validates it: the LED indicator remains ON and stops flashing. GB 01361 - Edition 01 - December 01 Description of each access keys NEXT RESET F1 Next menu or next step of a function, Next PARAMETER DIGIT, Displays the WARNING/ERROR message on the LCD when an error is detected. Resets original parameter value (before a new parameter value is validated) and deactivates the parameter key. + YES, or ON, or OPEN, or active, or increase value, or increase audio volume, or select more sensitive test mode. - NO, or OFF, or CLOSE, or deactive, or decrease value, or decrease audio volume, or select less sensitive test mode. Alcatel Vacuum Technology France - ASM 182 TD+ - ASM 192 T2D+ User’s Manual 3/4 C 20 Operating principle of the control panel Values adjustment with the control panel Procedure In many menus, some values can be adjusted (reject point, password, timer, ...). Please follow the procedure described below. Press function key of the desired line (where the value needs to be adjusted). For each parameter, use modification keys in order to adjust the value and go to the next parameter. - F1 + NEXT or Repeat the same operation as needed. F1 GB 01361 - Edition 01 - December 01 After the last modified parameter, press again the function key to validate the changes. 4/4 Alcatel Vacuum Technology France - ASM 182 TD+ - ASM 192 T2D+ User’s Manual