Download SmaFinger - Giga Tms Inc

Transcript
SmaFinger.NET
®
Contactless Smart Card & Fingerprint Reader
User’s Manual
REV.B
March 20, 2012
SmaFinger
PROMAG
REV.B
Table of Contents
Introduction .......................................................................................................................................... 4
1. Mifare® Application Directory (MAD) Support:............................................................ 6
2. User-Data Format: .............................................................................................................. 7
3. Wires Assignment: ............................................................................................................. 8
Software Operation .............................................................................................................................. 9
Mifare® Reader Utility: .......................................................................................................... 10
1. Connection ......................................................................................................................... 10
2. Instruction........................................................................................................................... 10

Mifare® Settings ......................................................................................................... 10
SmaFinger® Settings ................................................................................................ 12

Reader Settings ......................................................................................................... 14

LED / Buzzer Settings .............................................................................................. 15





Wiegand Settings ...................................................................................................... 17
ABA-TK2 ...................................................................................................................... 18
RS232/485 Settings ................................................................................................... 19
Test SmaFinger® Reader after Configuration .................................................... 21
SmaFinger® Formatter: ........................................................................................................ 22
1. Connection ......................................................................................................................... 22
2. Instruction........................................................................................................................... 23

Configure Settings .................................................................................................... 23

Renew Card................................................................................................................. 24

Format to a Card-Only Card ................................................................................... 25

Make a Card + Fingerprint Card ............................................................................ 26

Issue Fingerprint-Only Card ................................................................................... 27

Issue Multi-User Card............................................................................................... 28


Issue Manager Delete Card .................................................................................... 29
Issue Manager Enroll Card ..................................................................................... 29
3. Operation ............................................................................................................................ 30

Delete a User Account (Enrolled by Card+Fingerprints Card) in a Offline
Reader ...................................................................................................................................... 30

Delete Fingerprint Templates in a Offline Reader ............................................ 31

Append Fingerprint Templates to a Offline Reader ......................................... 32
Append a User Account to a Offline Reader ...................................................... 33

Delete a User Account (Enrolled by User Card) in a Offline Reader ........... 34

Appendix ............................................................................................................................................ 35
2
SmaFinger
PROMAG
REV.B
ANNEX A. Hardware Specification ................................................................................... 36
ANNEX B. Wiegand Interface ............................................................................................. 37
ANNEX C. ABA TK2 Interface............................................................................................. 38
ANNEX D. RS232 Interface ................................................................................................. 39
ANNEX E. External LED/Buzzer Control ......................................................................... 40
ANNEX F. Secure Mounting Installation .......................................................................... 41
ANNEX G. WebISP - Firmware Upgrade Utility .............................................................. 42
ANNEX H. History.................................................................................................................. 44
3
SmaFinger
PROMAG
REV.B
Introduction
4
SmaFinger
PROMAG
S
REV.B
®
maFinger is a fingerprint reader developed on the so-call contactless smart card 13.56 Mhz RFID technology. The
integration of biometric technology by fingerprint identification and 13.56Mhz RFID technology make Smafinger® be
capable of biometric and contactless performance without spending large amount of expenses in running system
upgrading with fingerprint system extension. On the aspect of personal privacy issue, SmaFinger supply the high secure
of protection on privacy concern due to every fingerprint is stored on a card. Also the reader itself supports Mifare
MAD1/MAD2 format make user end be able to issue their customized ID cards.
Features:
1. Biometric fingerprint reader and store fingerprint template in reader or in card.
2. Support standard TCP/IP interface and pure web-base administrator utility
3. Support MAD1/MAD2 standard, and support customer MAD-AID setting.
4. Support Anti-Collision (Two cards together can be read at the same time).
5. Support used card with data offset and length.
6. Support Multi Sectors.
7. Support Mifare® Standard 4K or Mifare® Standard 1K card.
8. Each Reader with Reader ID for multi-link application.
9. Output interface: Wiegand (Default), ABA-TK2 and RS232.
10. Wiegand output selectable from 26 bits to 128 bits.
11. RS232 output packet can be set with Header, Reader ID and Trailer.
Application:
1. Access Control.
2. Time Attendance.
3. Guest Registration System.
4. Academic Services.
5. Info Services.
5
SmaFinger
PROMAG
REV.B
1. Mifare® Application Directory (MAD) Support:
®
®
SmaFinger support the MAD format card, the MAD (Mifare application directory) standard proposes the
®
introduction of common data structures for card application directory entries. SmaFinger reader should take
advantage of this feature using those sector pointers instead of physical sector number.
Auto Mode
®
The SmaFinger will search the AID from mifare®
application directory (MAD) , then got a correct sector
number from MAD.
Request
Anticollision
No Tag
About MAD please see the web pages:
http://www.mifare.net
Card On Reader
http://www.semiconductors.philips.com/acrobat/other/id
Is MAD
Card
entification/M001824.pdf
No
Yes
AID Match
No
Yes
Get
Application Sector#
APP KEY
Authenticate
NG
PASS
Read Sector Data
Un-know
Output Data
6
SmaFinger
PROMAG
REV.B
2. User-Data Format:
®
SmaFinger will send out the data following the format as below, the user data length defined by the Data-Info.
At Wiegand output format, the data output length is fixed (defined by Number Of Bits), so the user data would
be cut if longer than Number of Bits, or the user data would be appended with zero "0" if shorter than Number
of Bits.
Byte 0
Block 0
Application
Block 1
Sector #n
Block 2
Byte 15
Data-Info
USER DATA (Max 128 Bytes)
Block 3
Data-Info
bit7
bit6
bit5
bit0
Data Type (11b)
Data Length
Data Type is fixed with 11b which meets "any other data" type of "Card Holder information" as MAD standard.
®
And data length is including the data with ending zero "0", so the number of data byte sent by SmaFinger is
equal to data length with one less for RS232 output.
®
Example: Data Length is 16, the SmaFinger reader only sends out 15 bytes for RS232 output.
7
SmaFinger
PROMAG
REV.B
3. Wires Assignment:
Color
Symbol
I/O
Description
Red
VCC
IN
Power Input : DC 7.5V~12V
Black
GND
IN
Power Ground
White
DATA 1
OUT
Wiegand Data 1 Signal / ABA TK2 Clock (Strobe)
Green
DATA 0
OUT
Wiegand Data 0 Signal / ABA TK2 Data
Yellow
TXD
OUT
RS232 TXD
(To Host RXD)
Blue
RXD
IN
RS232 RXD
(To Host TXD)
Orange
CP
OUT
Brown
LED/BUZEER
IN
ABA TK2 Card Present
External LED/BUZZER Control
Connect an RJ45 cable (via TCP/IP) or a reader-kit (via RS-232) before you configure
the SmaFinger
®
Reader.
Reader-KIT
ORANGE
BLACK
CP
GND
D1
D0
RX
TX
VCC
WHITE
RED
WAS-T0029
YELLOW
BLUE
GREEN
BROWN
" "
" "
The above housing is for reference only
9VDC
Note:
®
Reader-Kit is a test connection kit for SmaFinger configuration use. It is an optional item for purchasing.
8
SmaFinger
PROMAG
REV.B
Software Operation
9
SmaFinger
PROMAG
REV.B
Mifare® Reader Utility:
1. Connection
Method 1:
Click [Auto Scan] to search all port to find the device
Method 2:
Click [Connects] and choose the port to detect
device
2. Instruction
®
Mifare Settings
MAD-AID: (Default=4703)
®
MAD Application Identifier number is authorized and assigned by Mifare.net upon the customer’s
®
request for registered Application Identifier in a Mifare application open system
(AID:0000h~FFFFh).Or it is also possible for the user to define the AID himself for the application in
user defined closed system without registering into MAD group. According to the AID, SmaFinger
can find and read the corresponding sector on the MAD card.
10
®
SmaFinger
PROMAG
REV.B
App Key (KEY_A): (Default=FFFFFFFFFFFF)
®
App Key must be the same as the KEY_A of the card issued. This means SmaFinger only can read
the sector data on the card with the same KEY_A.
Encrypt: (Default=None)
Fraud prevention, Select Encrypt Mode (None, Encrypt 1, Encrypt 2, Encrypt 3, Encrypt 4, Encrypt 5)
to protected your card data. (Remark: Encrypt mode must to work together with the same encrypt
®
mode of "Mifare Card Issuer" software.)
®
Used Card (Not issued by "Mifare Card Issuer")
®
You have to indicate the data position in the card, when the card is not issued by "Mifare Card
Issuer" software. And you must set the "Offset" (Max 255, and base from zero) form the beginning of
sector and set your data "Length" (Max 12).
Example:
If your card data in the grey grid of sector, you have to set the "Offset" = 17, and set the "Length"=
12.
AID Sector (or Non-MAD Sector)
Block 0
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Block 1
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
Block 2
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
11
SmaFinger
PROMAG
REV.B
®
SmaFinger Settings
Finger Scan Success:
After finger scan success, the beeper will sound or not.
Manager Card:
Enable/Disable Offline function (Manager Card Function).
Card Only Mode:
Enable/Disable the "card-only" function. If disable this mode, the reader will be unable to read the
"card-only" card.
SF650 Fingerprint Security Level for FAR (False Acceptance Ratio) :
Level
Verification
(1:1)
Identification (1:N)
1~9
10~99
100~999
>=1000
Normal (Default)
1/10,000
1/10,000
1/100,000
1/1,000,000
1/10,000,000
Secure
1/100,000
1/100,000
1/1,000,000
1/10,000,000
1/100,000,000
1/1,000,000
1/1,000,000
1/10,000,000
1/100,000,000
1/100,000,000
More Secure
12
SmaFinger
PROMAG
REV.B
Door Control:
Set 5,10,15…75 seconds or disable for the delay open period time.
Command Set Control: (For 38400,n,8,1 Only)
RS232 door control command set frame as below:
STX
R
02h 52h
Command Table:
NUMBER
30h
31h~3Fh
NUMBER
30h~3Fh
CR
0Dh
Descriptions
Disable Door Control
Delay 5 seconds ~ 75 seconds
Sensitivity:
Set sensor sensitivity level, default=2
13
SmaFinger
PROMAG
REV.B
Reader Settings
®
Reader ID (Default=0): SmaFinger Reader ID for multi links application. (ID: 0~63).
Interface (Default=ABA-TK2):
®
SmaFinger can be set as Wiegand , RS232 or ABA-TK2 output.
Read Modes:
1. Card Data Only
®
Read card sector data only; If any error (ex. Mifare key error), the reader will show
"Card Invalid" status.
2. Card Data or CSN
®
Read card sector data; When any error (ex. Mifare key error), the reader will show
"CSN".
3. CSN Only
Read card CSN (card ID) only.
Buffering: To Enabled/Disabled the access data buffering. There are 32 access data can be stored
in the reader.
14
SmaFinger
PROMAG
REV.B
LED / Buzzer Settings
®
SmaFinger supports the LED/Alarm Configuration.
You can set the LED/Buzzer to indicate the system status for end-user.
Enable RS232 Command Set Control: (For 38400,n,8,1 Only)
RS232 LED/Buzzer command set frame as below:
STX
02h
J
4Ah
NUMBER (0~9)
30h~39h
CR
0Dh
Command Table:
NUMBER
0 (30h)
1 (31h)
2 (32h)
3 (33h)
4 (34h)
5 (35h)
6 (36h)
7 (37h)
8 (38h)
9 (39h)
Descriptions
Red & Green LED Off, Buzzer Off
Green LED ON
Green LED OFF
Red LED ON
Red LED OFF
Buzzer Beep once
Buzzer Beep 3 Times
Green LED ON with Beep once
Red LED ON with Beep 3 Times
Red & Green LED ON
A (41h)
B (42h)
Blue LED ON
Blue LED OFF
New!!
New!!
Remark: If “Enable RS232 command set control (for LED/Buzzer)” checkbox is
checked, the external LED/Buzzer control with high/low level control will be disabled.
15
SmaFinger
PROMAG
REV.B
Read Idle:
Show LED color after power on or idle state.
Brown wire = PULSE (or Card is valid):
Show LED color and beeps to indicate the end-user when brown wire = PULSE, or card was passed
®
by SmaFinger reader.
Brown wire = Inactive (or Card is invalid):
Show LED color and beeps to indicate the end-user when brown wire = Inactive, or card was failed
®
by the SmaFinger reader.
Brown wire = Active:
Show LED color and beeps to indicate the end-user that brown wire = Active signal from Host.
Brown wire Active level (Default=Disable):
Set Brown wire Active level condition with Host status.
-
Disable: Always disable the Brown wire. LED/Buzzer controls by reader self.
-
High: Active High / Normal keep in Low.
-
Low: Active Low / Normal keep in High.
Remark:
If set Active Low, you may have to connect brown wire to a pull-up resistor (1K~10K) with 5VDC).
Control Brown wire:
After Data Output: The brown wire will be enabling after finished output the card data or CSN.
(Default)
Any Time: The brown wire enabled in any time.
Note: See Annex E, the LED/Buzzer also can be controlled externally with
High/Low level control.
16
SmaFinger
PROMAG
REV.B
Wiegand Settings
Add Reader ID (Default=Disable):
Set Wiegand output data includes the Reader ID when it is checked.
Number of Bits (Default=26):
Set the Wiegand output type you want to meet your Host (or Terminal). It can be 26 to 128.
With parity:
Set data with or without parity bit. If enabled this, softer ware will be automatically add parity bit
when send out data.
Bit Sequence (Default=Standard):
Set the Wiegand output data sequence, it can be a standard data sequence (MSB first) or a reverse
data sequence (LSB first).
Byte Order (Default=High Byte First):
Set the Wiegand output data byte order; it can be high byte first or low byte first.
17
SmaFinger
PROMAG
REV.B
ABA-TK2
Number of Digital (Default=10):
Set the number of digital codes for TK2 output.
Add Reader ID (Default=Disable):
Add Reader ID into TK2 data.
Output Data Order (Default=MSB First): Set the TK2 data sequence.
Data Conversion(Default= BIN to DEC): Select card data format to convert,
®
-
BIN to DEC (card issue by Mifare Card Issuer Utility)
-
Decimal String (ex. "123456")
-
BCD
-
Direct (Memory Map)
-
Byte to DEC
Preamble Code: Set a number to add front of the output data
Postamble Code: Set a number to add back of the output data
18
SmaFinger
PROMAG
REV.B
RS232/485 Settings
Baud rate (Default=9600)
The working range can be set at 2400 to 57600 (depends on the device).
Data Sequence (Default= “MSB” first)
The output data sequence order can be set to "LSB" first or "MSB" first.
Package (Default = Header (02h) + CR + LF + Trailer (03h))
To set a packet which includes the “Header”, “Reader ID”, “Data Length”, “CR”, “LF” and “Trailer”.
(Header: 00h~FFh, Trailer: 00h~FFh).
Output Format (Default="Hex String")
The output format can be "Binary" or "Hex String”.
19
SmaFinger
PROMAG
REV.B
Note:
(1).Wiegand output data packet with Reader ID:
Standard
Reverse
Parity(Even)
Reader ID
(MSB)
Data Bits
(LSB)
Parity(Odd)
Parity(Odd)
Reader ID
(LSB)
Data Bits
(MSB)
Parity(Even)
(2).RS232 output data packet with Header, Reader ID and Trailer:
Header
Reader ID
(MSB)
Data Bytes
(LSB)
Trailer
(3).ABA-TK2 with Reader ID:
MSB First
SS
Reader ID
(MSB)
Digital Code
(LSB)
ES
LRC
LSB First
SS
Reader ID
(LSB)
Digital Code
(MSB)
ES
LRC
Remark:
®
SmaFinger all configuration settings are writable only, so user can not read the configuration settings from
®
SmaFinger to get the App Key, this is very important to protect your App Key and all configuration settings.
20
SmaFinger
PROMAG
REV.B
®
Test SmaFinger Reader after Configuration
®
®
After SmaFinger configuration is updated; you may use Mifare Reader Utility "Test" function to
®
test the SmaFinger to check if the configuration is done correctly. “Test” function is available when
using communication port connection only.
®
1. After set configuration on the Mifare Reader Utility software, you should click [Update Reader]
®
to update the current configuration to the SmaFinger Reader.
®
®
2. After SmaFinger configuration is updated; you may click [Test] to test SmaFinger Reader.
®
®
3. Get an issued Mifare card to approach to the SmaFinger reader and check the output data in
®
the window of SmaFinger "Output Test".
Example as below: Wiegand 34 bits output data with standard bit sequence (If "Bit Sequence" is
standard, Reverse will detect a wrong with parity error.)
Remark:
1. Using Reader-Kit to test Wiegand (or TK2) signal, this test may be failed if the processor of
computer is too slow.
2. Using Reader-Kit to test Wiegand (or TK2) signal, you have to connect to the physical Comm.
Port.
21
SmaFinger
PROMAG
REV.B
SmaFinger® Formatter:
Display COM port
1. Connection
if scan success.
Click [Auto Scan] to search the “PCR310” reader.
22
SmaFinger
PROMAG
REV.B
2. Instruction
Configure Settings
Save/Load the
configure file.
(.ini)
General Settings
-
Configure File Password: You can keep the configure file confidential by this password.
-
Language: To change the display language.
(Chinese/Czech/English/Japanese/Spanish/Thai)
Card Issue
These information are using to issue/format/read/write card.
®
The “SF Admin Key” and “SF APP Key” are using at SmaFinger format for fingerprint MAD.
23
SmaFinger
PROMAG
REV.B
Renew Card
Renew
®
After you click [Renew], the software will try to make a Mifare card revert to default settings.
That means, if one of the user def keys is correctly, then the card data will be formatted,
and all of the keys will be set to “FFFFFFFFFFFF”.
Remember Key
Check this to automatically stores user def keys after unloading this software.
By checked “Remember Key”, you do not need to type user def keys again every open the
®
SmaFinger Formatter software.
24
SmaFinger
PROMAG
REV.B
Format to a Card-Only Card
®
Click [Format to Card-Only Card] to makes a SmaFinger card-only card format,
and the entire card data will be erased after format complete.
Check the reader’s “Reader Mode”.
For “CSN Only” mode, read Card-Only Card can be passed without key,
For “Card Data” mode, read Card-Only Card can be passed after authenticate the APP Key pass.
25
SmaFinger
PROMAG
REV.B
Make a Card + Fingerprint Card
After make a Card-Only Card, read Manager Enroll Card to enter the enroll mode after the reader
in standby mode (LED status: blue on).
Standby Mode
Enroll Mode
Scan Mode
Success
In enroll mode (LED status: green blink), please read Card-Only Card to store UID. Or read
Manager Enroll Card to exit enroll mode.
In scan mode (LED status: blue blink), please scan user’s fingerprint till beeper sound. Or read
Manager Enroll Card to exit the enroll mode.
Scan same fingerprint again till beeper sound.
Finally, please read Card-Only Card twice to store fingerprint templates into the card and check
(LED status: green on).
26
SmaFinger
PROMAG
REV.B
Issue Fingerprint-Only Card
You can issue a Fingerprint-Only Card to enroll fingerprint templates into the reader, but no need to
use the software.
Click [Issue Fingerprint-Only Card] to issue the Fingerprint-Only Card.
27
SmaFinger
PROMAG
REV.B
Issue Multi-User Card
You can issue a Multi-User Card to append user accounts into the reader, but no need to use the
software.
A user account includes a 4 bytes random user data (HEX string), and the user’s fingerprint
templates.
Click [Issue Multi-User Card] to issue the Multi-User Card.
28
SmaFinger
PROMAG
REV.B
Issue Manager Delete Card
Click [Issue Manager Delete Card] to issue the Manager Delete Card.
Issue Manager Enroll Card
Click [Issue Manager Enroll Card] to issue the Manager Enroll Card.
29
SmaFinger
PROMAG
REV.B
3. Operation
Delete a User Account (Enrolled by Card+Fingerprints Card) in a Offline Reader
Standby mode
Delete mode
In standby mode, read Manager Delete Card to enter the delete mode.
In delete mode, please read Card + Fingerprints Card to start to delete. Or read Manager Delete
Card to exit the delete mode.
Read again Card + Fingerprints Card to confirm delete.
30
SmaFinger
PROMAG
REV.B
Delete Fingerprint Templates in a Offline Reader
Standby mode
Delete mode
In standby mode, read Manager Delete Card to enter the delete mode.
In delete mode, please scan the fingerprint to start to delete. Or read Manager Delete Card to exit
the delete mode.
Read again Card + Fingerprints Card to confirm delete.
After delete complete, all of the user’s data of the scan fingerprint will be erased.
31
SmaFinger
PROMAG
REV.B
Append Fingerprint Templates to a Offline Reader
First of all, read Manager Enroll Card to enter the enroll mode after the reader in standby mode
(LED status: blue on).
Standby Mode
Enroll Mode
Scan Mode
Success
In enroll mode (LED status: green blink), please read Fingerprint-Only Card to enter the scan mode.
Or read Manager Enroll Card to exit enroll mode.
In scan mode (LED status: blue blink), please scan user’s fingerprint till beeper sound. Or read
Manager Enroll Card to exit the enroll mode.
Scan same fingerprint again till beeper sound.
Finally, please read Fingerprint-Only Card to finish the scan mode (LED status: green on).
32
SmaFinger
PROMAG
REV.B
Append a User Account to a Offline Reader
First of all, read Manager Enroll Card to enter the enroll mode after the reader in standby mode
(LED status: blue on).
Standby Mode
Enroll Mode
Scan Mode
Success
In enroll mode (LED status: green blink), please read Multi-User Card to enter the scan mode. Or
read Manager Enroll Card to exit enroll mode.
In scan mode (LED status: blue blink), please scan user’s fingerprint till beeper sound. Or read
Manager Enroll Card to exit the enroll mode.
Scan same fingerprint again till beeper sound.
Finally, please read Multi-User Card to finish the scan mode (LED status: green on).
33
SmaFinger
PROMAG
REV.B
D
el
et
e
Ca
rd
Delete a User Account (Enrolled by User Card) in a Offline Reader
Manager
Standby mode
Delete mode
In standby mode, read Manager Delete Card to enter the delete mode.
In delete mode,
please read User Card to delete the user. Or read Manager Delete Card to exit the delete mode.
34
SmaFinger
PROMAG
REV.B
Appendix
35
SmaFinger
PROMAG
REV.B
ANNEX A. Hardware Specification
Reader Specification:
SmaFinger
Major Feature
Mifare® Application Directory Reader
Access Control & Security
Card Type
ISO14443A, Mifare Class
(Mifare® 1K, Mifare® 4K for MAD1/MAD2)
RF Frequency
13.56MHz
RF Distance2
50mm (Using the MFA01 Mifare® card of GIGA-TMS INC.)
DC Power
7.5VDC~12VDC (Max 250mA @ 12V)
Interface
Wiegand 26~128 bits (Standard / Reverse)
RS232 2400~57600(baud rate)
ABA-TK2 40IPS: 2~48 codes
Power Input
DC 7.5~12V
Power Consuming
210mA @ 12V
Operating Temp.
0~50 degree C
Humidity
10~90% Humidity
Dimension
H130.0mm x W54.0mm x D43.0mm
Note:
1. Mifare® Class: Mifare® Standard 1K/4K/Pro (without Mifare® Ultra-Light).
2. SmaFinger® RF distance can reach up to 50mm with MFA01 (Mifare® Standard 1K Card)
of GIGA-TMS INC.
36
SmaFinger
PROMAG
REV.B
ANNEX B. Wiegand Interface
The Data 1 and Data 0 signals are held at a logic high level unit, the reader is ready to send a data stream.
The reader places data as asynchronous low-going pulses on the Data 1 or Data 0 lines to transmit the data
stream to Host. The Data 1 and Data 0 pulses will allowable pulse width times and pulse interval times for the
®
SmaFinger reader.
Data 1 Signal
Data 0 Signal
`
Tpw
Tpi
Tpw
Tpi
Pulse Times
Symbol
Description
Typical Time
Tpw
Pulse Width Time
100us +/- 3%
Tpi
Pulse Interval Time
1.9ms +/- 3%
Wiegand Packet (Without Reader ID)
Standard (Default)
Reverse
(Option)
Parity(Even)
(MSB)
Data Bits
(LSB)
Parity(Odd)
Parity(Odd)
(LSB)
Data Bits
(MSB)
Parity(Even)
Connect the Wiegand wires, example as below: (The pull high resister must >= 10K Ohm)
HOST/Terminal
5VDC
Pull high resistor
9~12VD
SmaFinger
(Red)
10K
10K
ohm
ohm
Data 1 (White)
Data 0 (Green)
(Black)
GND
GND
Optional: External LED/Buzzer Control (Brown)
37
>=10K Ohm
SmaFinger
PROMAG
REV.B
ANNEX C. ABA TK2 Interface
The timing for Card Present, Clock (Strobe) and Data , example as below:
/CARD PRESENT
Leading Zero
Data
Trailing Zero
/DATA
/STROBE
(CLOCK)
0
0
0 . . . 0
1
1
0
1
0
0
1 . . .
0
0
0
STROBE Width Approximately 25~50% Of Bit Time
Bit Time 40IPS (min:280us, typ:330us, max:480us)
DATA
The data signal is valid while the clock is low. If the Data signal is high, the bit
is a zero. If the Data signal is low, the bit is a one.
CLOCK (STROBE)
The Clock signal indicates when Data is valid. It is recommended that Data be loaded
by the user with the leading edge (negative) of the Strobe.
CARD PRESENT
Card Present will go low after flux reversals from the Reader. Card Present will return
high after the last flux reversal.
Connect the ABA TK2 wires, example as below:
HOST/Terminal
9~12VD
(Red)
SmaFinger
Card Present (Orange)
Clock (White)
Data
(Green)
(Black)
GND
GND
Optional: External LED/Buzzer Control (Brown)
38
SmaFinger
PROMAG
REV.B
ANNEX D. RS232 Interface
Connect the RS232 wires, example as below:
HOST/Terminal
9~12VD
(Red)
SmaFinger
TXD (Yellow)
GND (Black)
GND
GND
Optional: External LED/Buzzer Control (Brown)
39
SmaFinger
PROMAG
REV.B
ANNEX E. External LED/Buzzer Control
SmaFinger supports the external LED/Buzzer control for Terminal (or Host) to prompt end-user the card data
is invalid or valid. Use Brown wire to control the LED/Buzzer of SmaFinger
Examples as below: (Active High)
(1) Show External Invalid Status
Data Output
Alarm Control (Brown)
Min 100ms
(2) Show Card Valid Status
Data Output
Alarm Control (Brown)
Min 100ms
Note:
1. Send one pulse to show the "External Invalid" LED/Buzzer Status.
2. Send three or more pulse to show the "Card Valid" LED/Buzzer status.
3. You can configure the LED/Buzzer status by Mifare Reader utility.
40
SmaFinger
PROMAG
REV.B
ANNEX F. Secure Mounting Installation
1. Attach the bottom plate label on the target
2. After fixing SmaFinger with attached screws
position. Drill the holes to match the bottom plate
(using the L-shape spanner), apply screw cover
then fix SmaFinger reader.
plate for completion.
WALL
WALL
L-shape
screw cover plate
Remark:
SmaFinger is not designed for outdoor usage. Avoid the
damage from sunshine or rains.
To keep SmaFinger in good performance, it is recommended
to have regular maintenance and clearance of the physical
reader.
41
SmaFinger
PROMAG
REV.B
ANNEX G. WebISP - Firmware Upgrade Utility
SmaFinger also supports the ISP (In-System Program) function to upgrade the reader’s
firmware.
Install WebISP (included in CD-ROM) in your PC (Windows System) first and follow the
steps as below: (First of all, connect the reader or the programmer to PC via RS232
connection and make sure they are powered on.)
Step 1: Input your account
(UserName and Password)
Note:
Contact us to get your
account when needed.
Step 2: Click [Start Check]
to automatically check the
firmware version from our
FTP server.
Show the update
If your reader’s or
history.
programmer’s firmware out
of date, then WebISP will
prompt you to update the
firmware. Click [Update]
to begin Updating the
firmware.
Note:
1. The WebISP will auto
scan all Comm ports to
search the reader or
programmer.
2. The WebISP will show the
[Update Information]
and list the update
history.
42
SmaFinger
PROMAG
REV.B
Step 3: After “Update
Finish” message appears on
the screen, it may still
need to take several
seconds to complete the
update until LED shows back
to normal.
Update finished
43
SmaFinger
PROMAG
REV.B
ANNEX H. History
Rev A: September 28, 2010
Initial SmfFinger Configurable Sector Reader.
Rev B: July 27, 2011 (Kylie)
Specific How to install WebISP. (P.23)
September 30, 2011 (Kylie)
Update pics.
‘Sequence’ label edit to ‘Output Data Order’ (p.14)
October 03, 2011 (Kylie)
Modify several grammar mistakes.
Add remark (p.16)
Modify update describes (step #3). (p.24)
October 18, 2011 (Kylie)
Modify “Command Table” expressions. (p.11)
October 19, 2011 (Kylie)
Modify “Command Table” descriptions and remark. (p.11)
January 01, 2012 (Kylie)
Modify ReaderID’s limit. (p.10)
January 11, 2012
(Kylie)
Modify data length limited to 12. (p.8)
February 08, 2012 (Kylie)
Modify CardOnlyMode and FingerScanSuccess descriptions. (p.9)
March 20, 2012 (Kylie)
Add “Formatter” describes.
Re-typesetting.
44
SmaFinger
PROMAG
REV.B
PROMAG
®
GIGA-TMS INC.
http://www.gigatms.com.tw
mailto:promag@gigatms.com.tw
TEL : +886-2-26954214
FAX : +886-2-26954213
Office: 8F, No. 31,Lane 169, Kang-Ning St.,Hsi-Chih, Taipei, Taiwan
45