Download Mitsubishi Electric Mr. Slim PEAD-RP GA Technical data
Transcript
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS July 2009 TECHNICAL DATA BOOK R410A <Indoor unit> INVERTER [Model names] PLA-RP·BA/BA2/BA3 PEAD-RP·JA(L) PEA-RP·GA PKA-RP·HAL PKA-RP·KAL PCA-RP·KA PCA-RP·HA PSA-RP·GA <Outdoor unit> PUHZ-RP35/50/60/71VHA4 PUHZ-RP100/125/140VKA PUHZ-RP100/125/140YKA PUHZ-RP200/250YKA [Model names] No. OCS16 CONTENTS 1. REFERENCE SERVICE MANUAL·············································2 2. SPECIFICATIONS ······································································3 3. OUTLINES AND DIMENSIONS ···············································24 4. WIRING DIAGRAM···································································44 5. REFRIGERANT SYSTEM DIAGRAM ······································58 6. PERFORMANCE CURVES ······················································63 7. CORRECTION FACTORS ························································65 8. APPLICABLE EXTENSION PIPE FOR EACH MODEL ··········66 9. AIR FLOW DATA ······································································75 10. NOISE CRITERION CURVES ··················································90 11. OPTIONAL PARTS ··································································106 kW Model 1 REFERENCE SERVICE MANUAL For information on service, please refer to the service manual as follows. 1-1. INDOOR UNIT SERVICE MANUAL Service Manual No. Model name Service Ref. PLA-RP35/50/60/71/100/125BA PLA-RP71/125/140BA2 PLA-RP35/50/60/71/100/125BA#2.UK PLA-RP71/125/140BA2.UK PLA-RP100BA3 PLA-RP100BA3 PCA-RP50/60/71/100/125/140KA PCA-RP50/60/71/100/125/140KA PCA-RP71/125HA PCA-RP71/125HA#1 PKA-RP35/50HAL PKA-RP35/50HAL PKA-RP60/71/100KAL PKA-RP60/71/100KAL.TH PSA-RP71/100/125/140GA PSA-RP71/100/125/140GA#1 PEAD-RP35/50/60/71/100/125/140JA(L) PEAD-RP35/50/60/71/100/125/140JA(L).UK HWE08130 BWE08240 PEA-RP200/250/400/500GA PEA-RP200/250/400/500GA.TH-AF PEA-RP200/250GA.TH-AFMF HWE0708A Model name Service Ref. Service Manual No. PUHZ-RP35/50/60/71VHA4 PUHZ-RP100/125/140VKA PUHZ-RP100/125/140YKA PUHZ-RP200/250YKA PUHZ-RP35/50/60/71VHA4 PUHZ-RP100/125/140VKA PUHZ-RP100/125/140YKA PUHZ-RP200/250YKA OCH412 OCB412 OCH459 OCB459 OCH454 OCB454 OC329 OCH453 OCB453 OCH452 OCB452 OC332 1-2. OUTDOOR UNIT 2 OCH451 OCB451 SPECIFICATIONS 2 2-1. CEILING CASSETTE TYPE Model name Indoor unit Outdoor unit Capacity Cooling Btu/h kW kW Total input EER Energy label class SHF Capacity Heating Btu/h kW kW Total input COP Energy label class Booster heater Phase Cycle Voltage Breaker size Air flow (Low-Medium2-Medium1-High) Power supply Indoor unit kW : Hz V A CMM CFM Pa External pressure Sound level (Low-Medium2-Medium1-High) dB(A) External finish (Panel) Dimension Unit (Panel) W : mm D : mm H : mm W : inch D : inch H : inch kg lbs mm inch CMM CFM dB(A) dB(A) Weight Unit (Panel) Field drain pipe O.D. Outdoor unit Air flow Sound level at cooling Sound level at heating External finish Dimension W : mm D : mm H : mm W : inch D : inch H : inch kg lbs mm inch mm inch m m Weight Refrigerant pipe size Gas side O.D. Liquid side O.D. Height difference Length Refrigerant pipe length NOTE: 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27 (80°F) W.B. 19 (66°F) Heating Indoor : D.B. 20 (68°F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Upper Lower Upper Heating Lower Cooling limit limit limit limit D.B. D.B. D.B. D.B. Indoor 35°C, W.B. 22.5°C 19°C, W.B. 15°C 28°C 17°C D.B. D.B. D.B. D.B. PLA-RP35BA PUHZ-RP35VHA4 12,300 3.6(1.6-4.5) 1.07 3.36 A 0.84 14,000 4.1(1.6-5.2) 1.12 3.66 A – PLA-RP50BA PUHZ-RP50VHA4 17,100 5.0(2.3-5.6) 1.55 3.23 A 0.81 20,500 6.0(2.5-7.3) 1.66 3.61 A – 1 50 230 16 11-12-13-15 390-425-460-530 0 12-14-16-18 425-495-565-635 0 27-28-29-31 28-29-31-32 White Munsell 6.4Y 8.9/0.4 840 (950) 840 (950) 258 (35) 33-1/16 (37-3/8) 33-1/16 (37-3/8) 10-3/16 (1-3/8) 22(6) 49(13) 32 1-1/4 35 1,240 44 46 Ivory Munsell 3Y 7.8/1.1 800 300+23 600 31-1/2 11-13/16 + 7/8 23-5/8 42 93 12.7 1/2 6.35 1/4 Max. 30 Max. 50 Outdoor : D.B. 35 (95°F) W.B. 24 (75°F) Outdoor : D.B. 7 (45°F) W.B. 6 (43°F) Outdoor 46°C -5°C + 21°C, W.B. 15°C -11°C, W.B. -12°C 3 3. Guaranteed voltage 198~264V, 50Hz 4. Above data are based on the indicated voltage. Indoor unit Single phase 230V 50Hz Outdoor unit Single phase 230V 50Hz + If optional air protect guide installed. D.B.-15 Model name Indoor unit PLA-RP60BA Outdoor unit Cooling Capacity Total input Btu/h 20,500 24,200 kW 6.0(2.7-6.7) 7.1(3.3-8.1) kW EER Energy label class SHF Heating Capacity Total input 23,900 27,300 8.0(3.5-10.2) kW 1.82 2.15 3.85 3.72 A – – Cycle Hz 50 Voltage V 230 1 A Sound level (Low-Medium2-Medium1-High) 25 CMM 12-14-16-18 14-16-18-21 CFM 425-495-565-635 495-565-635-740 Pa 0 0 dB(A) 28-29-31-32 28-30-32-34 External finish (Panel) White Munsell 6.4Y 8.9/0.4 Dimension W : mm 840 (950) Unit (Panel) D : mm 840 (950) H : mm 258 (35) W : inch 33-1/16 (37-3/8) D : inch 33-1/16 (37-3/8) H : inch 10-3/16 (1-3/8) Weight kg 23(6) Unit (Panel) lbs 51(13) Field drain pipe O.D. Air flow mm 32 inch 1-1/4 CMM 60 CFM 2,120 Sound level at cooling dB(A) 47 Sound level at heating dB(A) External finish Weight Gas side O.D. Liquid side O.D. NOTE: Upper limit Lower limit Upper limit Heating Lower limit W : mm 950 D : mm 330+30 H : mm 943 W : inch 37-3/8 D : inch 13 + 1-3/16 H : inch 37-1/8 kg 67 lbs 148 mm 15.88 inch 5/8 mm 9.52 inch 3/8 Height difference m Max. 30 Length m Max. 50 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27 (80°F) W.B. 19 (66°F) Heating Indoor : D.B. 20 (68°F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Cooling 48 Ivory Munsell 3Y 7.8/1.1 Dimension Refrigerant pipe length – : External pressure Refrigerant pipe size – 0.73 Phase Air flow (Low-Medium2-Medium1-High) Outdoor unit A 0.76 7.0(2.8-8.2) kW Breaker size Indoor unit 2.09 3.40 kW Energy label class Booster heater 1.60 3.75 Btu/h COP Power supply PLA-RP71BA PUHZ-RP71VHA4 PUHZ-RP60VHA4 Indoor D.B. 35°C, W.B. 22.5°C D.B. 19°C, W.B. 15°C D.B. 28°C D.B. 17°C Outdoor : D.B. 35 (95°F) W.B. 24 (75°F) Outdoor : D.B. 7 (45°F) W.B. 6 (43°F) Outdoor D.B. 46°C D.B. -5°C + D.B. 21°C, W.B. 15°C D.B. -20°C, W.B. -20°C 4 3. Guaranteed voltage 198~264V, 50Hz 4. Above data are based on the indicated voltage. Indoor unit Single phase 230V 50Hz Outdoor unit Single phase 230V 50Hz + If optional air protect guide installed. D.B.-15 Model name Indoor unit Outdoor unit Cooling Capacity PLA-RP71BA2 PLA-RP100BA PLA-RP100BA3 PUHZ-RP71VHA4 PUHZ-RP100VKA PUHZ-RP100VKA Btu/h 24,200 34,100 34,100 kW 7.1(3.3-8.1) 10.0(4.9-11.4) 10.0(4.9-11.4) 1.90 2.65 2.39 3.74 3.77 4.18 Total input kW EER Energy label class SHF Heating Capacity A 0.74 27,300 38,200 38,200 kW 8.0(3.5-10.2) 11.2(4.5-14.0) 11.2(4.5-14.0) kW 1.90 2.79 2.43 4.21 4.01 4.61 A – A – – – COP Energy label class Booster heater kW Phase : Cycle Hz 50 Voltage V 230 Breaker size Indoor unit – 0.74 Btu/h Total input Power supply A 0.73 Air flow (Low-Medium2-Medium1-High) A 25 32 CMM 14-16-18-21 20-23-26-30 CFM 495-565-635-740 710-810-920-1060 Pa 0 0 dB(A) 28-30-32-34 32-34-37-40 External pressure Sound level (Low-Medium2-Medium1-High) 1 External finish (Panel) White Munsell 6.4Y 8.9/0.4 Dimension W : mm Unit (Panel) D : mm 840 (950) 840 (950) H : mm 258 (35) W : inch D : inch 33-1/16 (37-3/8) H : inch 10-3/16 (1-3/8) Weight kg 23(6) 25(6) 26(6) Unit (Panel) lbs 51(13) 55(13) 32 57(13) Field drain pipe O.D. mm inch Outdoor unit Air flow 1-1/4 60 110 CFM 2,120 3,880 Sound level at cooling dB(A) 47 49 Sound level at heating dB(A) 48 Dimension 51 Ivory Munsell 3Y 7.8/1.1 W : mm 950 D : mm H : mm 943 1,338 W : inch 37-3/8 41-5/16 37-1/8 kg 67 116 lbs 148 256 Gas side O.D. mm Liquid side O.D. 52-11/16 15.88 inch 5/8 mm 9.52 inch 3/8 Height difference m Max. 30 Length m 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27 (80°F) W.B. 19 (66°F) Heating Indoor : D.B. 20 (68°F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Upper limit Lower limit Upper limit Heating Lower limit Cooling 13 + 1-3/16 H : inch Weight NOTE: 1,050 330+30 D : inch Refrigerant pipe length 11-3/4 (1-3/8) CMM External finish Refrigerant pipe size 298 (35) 33-1/16 (37-3/8) Indoor D.B. 35°C, W.B. 22.5°C D.B. 19°C, W.B. 15°C D.B. 28°C D.B. 17°C Max. 50 Max. 75 Outdoor : D.B. 35 (95°F) W.B. 24 (75°F) Outdoor : D.B. 7 (45°F) W.B. 6 (43°F) Outdoor D.B. 46°C D.B. -5°C + D.B. 21°C, W.B. 15°C D.B. -20°C, W.B. -20°C 5 3. Guaranteed voltage 198~264V, 50Hz 4. Above data are based on the indicated voltage. Indoor unit Single phase 230V 50Hz Outdoor unit Single phase 230V 50Hz + If optional air protect guide installed. D.B.-15 Model name Indoor unit Outdoor unit Cooling Capacity Total input PLA-RP125BA PLA-RP125BA2 PLA-RP140BA2 PUHZ-RP125VKA PUHZ-RP125VKA PUHZ-RP140VKA Btu/h 42,700 42,700 47,800 kW 12.5(5.5-14.0) 12.5(5.5-14.0) 14.0(6.2-15.3) kW EER Energy label class SHF Heating Capacity Total input – A A 0.71 0.71 0.71 47,800 47,800 54,600 14.0(5.0-16.0) 14.0(5.0-16.0) 16.0(5.7-18.0) kW 3.86 3.50 4.32 3.63 4.00 3.70 – A A – – – kW Phase : Cycle Hz 50 Voltage V 230 Breaker size Indoor unit 4.36 3.21 kW Energy label class Power supply 3.67 3.41 Btu/h COP Booster heater 3.83 3.26 1 A Air flow (Low-Medium2-Medium1-High) External pressure Sound level (Low-Medium2-Medium1-High) 32 22-25-28-31 22-25-28-31 24-26-29-32 CFM 780-880-990-1090 780-880-990-1090 850-920-1020-1130 Pa 0 0 0 dB(A) 34-36-39-41 34-36-39-41 36-39-42-44 External finish (Panel) White Munsell 6.4Y 8.9/0.4 Dimension W : mm 840 (950) Unit (Panel) D : mm 840 (950) H : mm 298 (35) W : inch 33-1/16 (37-3/8) D : inch 33-1/16 (37-3/8) H : inch 11-3/4 (1-3/8) Weight kg 25(6) 27(6) 27(6) Unit (Panel) lbs 55(13) 60(13) mm 60(13) 32 inch 1-1/4 Field drain pipe O.D. Outdoor unit Air flow CMM 120 CFM 4,230 Sound level at cooling dB(A) 50 Sound level at heating dB(A) 52 External finish Dimension Ivory Munsell 3Y 7.8/1.1 W : mm 1,050 D : mm 330+30 H : mm 1,338 W : inch 41-5/16 D : inch 13 + 1-3/16 H : inch Weight Refrigerant pipe size Gas side O.D. NOTE: 116 119 lbs 256 262 15.88 inch 5/8 mm 9.52 inch 3/8 Height difference m Max. 30 Length m Max. 75 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27 (80°F) W.B. 19 (66°F) Heating Indoor : D.B. 20 (68°F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Upper limit Lower limit Upper limit Heating Lower limit Cooling 52-11/16 kg mm Liquid side O.D. Refrigerant pipe length 40 CMM Indoor D.B. 35°C, W.B. 22.5°C D.B. 19°C, W.B. 15°C D.B. 28°C D.B. 17°C Outdoor : D.B. 35 (95°F) W.B. 24 (75°F) Outdoor : D.B. 7 (45°F) W.B. 6 (43°F) Outdoor D.B. 46 D.B. -5 + D.B. 21, W.B. 15 D.B. -20, W.B. -20 6 3. Guaranteed voltage 198~264V, 50Hz 4. Above data are based on the indicated voltage. Indoor unit Single phase 230V 50Hz Outdoor unit Single phase 230V 50Hz + If optional air protect guide installed. D.B.-15 Model name Indoor unit Outdoor unit Cooling Capacity Total input Heating Btu/h 34,100 34,100 kW 10.0(4.9-11.4) 10.0(4.9-11.4) kW 2.65 2.39 3.77 4.18 – A SHF 0.74 0.74 Total input Btu/h 38,200 38,200 kW 11.2(4.5-14.0) 11.2(4.5-14.0) kW 2.79 2.43 4.01 4.61 – A COP Energy label class Booster heater kW – : Cycle Hz 50 Voltage V 400 16 CMM 20-23-26-30 20-23-26-30 CFM 710-810-920-1,060 710-810-920-1,060 Pa 0 0 dB(A) 32-34-37-40 32-34-37-40 External pressure Sound level (Low-Medium2-Medium1-High) 3 A Air flow (Low-Medium2-Medium1-High) External finish (Panel) White Munsell 6.4Y 8.9/0.4 Dimension W : mm 840 (950) Unit (Panel) D : mm 840 (950) H : mm 298 (35) W : inch 33-1/16 (37-3/8) D : inch 33-1/16 (37-3/8) H : inch 11-3/4 (1-3/8) Weight kg 25 (6) 26 (6) Unit (Panel) lbs 55 (13) 57 (13) Field drain pipe O.D. Outdoor unit Air flow mm 32 inch 1-1/4 CMM 110 CFM 3,880 Sound level at cooling dB(A) 49 Sound level at heating dB(A) 51 External finish Dimension Ivory Munsell 3Y 7.8/1.1 W : mm 1,050 D : mm 330+30 H : mm 1,338 W : inch 41-5/16 D : inch 13 + 1-3/16 H : inch 52-11/16 kg 124 Weight Refrigerant pipe size Gas side O.D. Liquid side O.D. Refrigerant pipe length NOTE: lbs 273 mm 15.88 inch 5/8 mm 9.52 inch 3/8 Height difference m Max. 30 Length m Max. 75 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27 (80°F) W.B. 19 (66°F) Heating Indoor : D.B. 20 (68°F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Upper limit Lower limit Upper limit Heating Lower limit Cooling – Phase Breaker size Indoor unit PLA-RP100BA3 PUHZ-RP100YKA EER Energy label class Capacity Power supply PLA-RP100BA PUHZ-RP100YKA Indoor D.B. 35°C, W.B. 22.5°C D.B. 19°C, W.B. 15°C D.B. 28°C D.B. 17°C Outdoor : D.B. 35 (95°F) W.B. 24 (75°F) Outdoor : D.B. 7 (45°F) W.B. 6 (43°F) Outdoor D.B. 46°C D.B. -5°C + D.B. 21°C, W.B. 15°C D.B. -20°C, W.B. -20°C 7 3. Guaranteed voltage Indoor unit 198~264V, 50Hz Outdoor unit 342~457V, 50Hz 4. Above data are based on the indicated voltage. Indoor unit Single phase 230V 50Hz Outdoor unit 3 phase 400V 50Hz If optional air protect guide installed. D.B.-15 Model name Indoor unit PLA-RP125BA PLA-RP125BA2 PLA-RP140BA2 Btu/h PUHZ-RP125YKA 42,700 PUHZ-RP125YKA 42,700 PUHZ-RP140YKA 47,800 kW 12.5(5.5-14.0) 12.5(5.5-14.0) 14.0(6.2-15.3) kW 3.83 3.67 4.36 EER Energy label class 3.26 3.41 3.21 – A A SHF 0.71 0.71 0.71 Outdoor unit Cooling Capacity Total input Heating Capacity Total input Btu/h 47,800 47,800 54,600 kW 14.0(5.0-16.0) 14.0(5.0-16.0) 16.0(5.7-18.0) kW 3.86 3.50 4.32 3.63 4.00 3.70 – A A – – – COP Energy label class Booster heater Power supply kW Phase : Cycle Hz 50 Voltage V 400 Breaker size Indoor unit 3 A Air flow (Low-Medium2-Medium1-High) External pressure Sound level (Low-Medium2-Medium1-High) 16 CMM 22-25-28-31 22-25-28-31 24-26-29-32 CFM 780-880-990-1090 780-880-990-1090 850-920-1020-1130 Pa 0 0 0 dB(A) 34-36-39-41 34-36-39-41 36-39-42-44 White Munsell 6.4Y 8.9/0.4 External finish (Panel) Dimension W : mm 840 (950) Unit (Panel) D : mm 840 (950) H : mm 298 (35) W : inch 33-1/16 (37-3/8) D : inch 33-1/16 (37-3/8) 11-3/4 (1-3/8) H : inch Weight kg 25(6) 27(6) 27(6) Unit (Panel) lbs 55(13) 60(13) mm 60(13) 32 inch 1-1/4 Field drain pipe O.D. Outdoor unit CMM 120 CFM 4,230 Sound level at cooling dB(A) 50 Sound level at heating dB(A) Air flow 52 Ivory Munsell 3Y 7.8/1.1 External finish Dimension W : mm 1,050 D : mm 330+30 H : mm 1,338 W : inch 41-5/16 D : inch 13 + 1-3/16 52-11/16 H : inch Weight Refrigerant pipe size Gas side O.D. NOTE: lbs 278 132 291 15.88 inch 5/8 mm 9.52 inch 3/8 Height difference m Max. 30 Length m Max. 75 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27 (80°F) W.B. 19 (66°F) Heating Indoor : D.B. 20 (68°F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Upper limit Lower limit Upper limit Heating Lower limit Cooling 126 mm Liquid side O.D. Refrigerant pipe length kg Indoor D.B. 35°C, W.B. 22.5°C D.B. 19°C, W.B. 15°C D.B. 28°C D.B. 17°C Outdoor : D.B. 35 (95°F) W.B. 24 (75°F) Outdoor : D.B. 7 (45°F) W.B. 6 (43°F) Outdoor D.B. 46°C D.B. -5°C + D.B. 21°C, W.B. 15°C D.B. -20°C, W.B. -20°C 8 3. Guaranteed voltage Indoor unit 198~264V, 50Hz Outdoor unit 342~457V, 50Hz 4. Above data are based on the indicated voltage. Indoor unit Single phase 230V 50Hz Outdoor unit 3 phase 400V 50Hz If optional air protect guide installed. D.B.-15 2-2. CEILING-CONCEALED TYPE Model name Cooling Indoor unit PEAD-RP35JA(L) PEAD-RP50JA(L) Outdoor unit PUHZ-RP35VHA4 PUHZ-RP50VHA4 Capacity Total input Btu/h 12,300 17,100 kW 3.6(1.6-4.5) 5.0(2.3-5.6) kW EER Energy label class SHF Heating Capacity Total input A 0.84 14,000 20,500 4.1(1.6-5.2) 6.0(2.5-7.3) kW 1.10 1.56 3.73 3.85 A A kW - - Phase : Cycle Hz 50 Voltage V 230 Breaker size Indoor unit A 0.85 kW Energy label class Power supply 1.55(1.53) 3.23(3.27) Btu/h COP Booster heater 1.02(1.00) 3.53(3.60) 1 A 16 Air flow CMM 10-12-14 12-14.5-17 (Low-Middle-High) CFM 353-424-494 424-512-600 External pressure Pa Sound level dB(A) 35/50/70/100/150 23-27-30 26-31-35 (Low-Middle-High/ 50Pa) External finish Galvanized sheets Dimension W : mm 900 D : mm 732 H : mm 250 W : inch 35-7/16 D : inch 28-7/8 H : inch Weight Field drain pipe O.D. Outdoor unit Air flow 26(25) lbs 58(56) inch 1-1/4 35 CFM 1,240 Sound level at cooling dB(A) 44 Sound level at heating dB(A) 800 D : mm 300+23 H : mm 600 31-1/2 D : inch 11-13/16 + 7/8 H : inch 23-5/8 Gas side O.D. kg 42 lbs 93 mm 12.7 inch 1/2 mm 6.35 inch 1/4 Height difference m Max. 30 Length m Max. 50 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27 (80°F) W.B. 19 (66°F) Heating Indoor : D.B. 20 (68°F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Upper limit Lower limit Upper limit Heating Lower limit W : mm W : inch Liquid side O.D. Cooling 46 Ivory Munsell 3Y 7.8/1.1 Weight NOTE: 62(60) 32 CMM Dimension Refrigerant pipe length 28(27) mm External finish Refrigerant pipe size 9-7/8 kg Indoor D.B. 35°C, W.B. 22.5°C D.B. 19°C, W.B. 15°C D.B. 28°C D.B. 17°C Outdoor : D.B. 35 (95°F) W.B. 24 (75°F) Outdoor : D.B. 7 (45°F) W.B. 6 (43°F) Outdoor D.B. 46°C D.B. -5°C + D.B. 21°C, W.B. 15°C D.B. -11°C, W.B. -12°C 9 3. Guaranteed voltage 198~264V, 50Hz 4. Above data are based on the indicated voltage. Indoor unit Single phase 230V 50Hz Outdoor unit Single phase 230V 50Hz + If optional air protect guide installed. D.B.-15 Model name Cooling Indoor unit PEAD-RP60JA(L) PEAD-RP71JA(L) Outdoor unit PUHZ-RP60VHA4 PUHZ-RP71VHA4 Capacity Total input Btu/h 20,500 24,200 kW 6.0(2.7-6.7) 7.1(3.3-8.1) kW EER Energy label class SHF Heating Capacity Total input A 0.83 23,900 27,300 7.0(2.8-8.2) 8.0(3.5-10.2) kW 1.75 2.00 4.00 4.00 A A kW - - Phase : Cycle Hz 50 Voltage V 230 Breaker size Indoor unit A 0.83 kW Energy label class Power supply 2.03(2.01) 3.50(3.53) Btu/h COP Booster heater 1.60(1.58) 3.75(3.80) 1 A 25 Air flow CMM 14.5-18-21 17.5-21-25 (Low-Middle-High) CFM 512-636-742 618-742-883 External pressure Pa Sound level dB(A) 35/50/70/100/150 25-29-33 26-30-34 (Low-Middle-High/ 50Pa) External finish Galvanized sheets Dimension W : mm 1,100 D : mm 732 H : mm 250 W : inch 43-5/16 D : inch 28-7/8 H : inch Weight Field drain pipe O.D. 9-7/8 kg 33(32) lbs 73(71) Air flow CMM 60 60 CFM 2,120 2,120 Sound level at cooling dB(A) 47 47 Sound level at heating dB(A) 48 External finish 48 Ivory Munsell 3Y 7.8/1.1 Dimension Weight W : mm 950 950 D : mm 330+30 330+30 H : mm 943 943 W : inch 37-3/8 37-3/8 D : inch 13 + 1-3/16 13 + 1-3/16 H : inch 37-1/8 kg Gas side O.D. Liquid side O.D. Refrigerant pipe length NOTE: Upper limit Lower limit Upper limit Heating Lower limit 148 mm 15.88 inch 5/8 15.88 5/8 mm 9.52 9.52 inch 3/8 3/8 Height difference m Max. 30 Max. 30 Length m Max. 50 Max. 50 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27 (80°F) W.B. 19 (66°F) Heating Indoor : D.B. 20 (68°F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Cooling 37-1/8 67 lbs Refrigerant pipe size 73(71) 32 1-1/4 mm inch Outdoor unit 33(32) Indoor D.B. 35°C, W.B. 22.5°C D.B. 19°C, W.B. 15°C D.B. 28°C D.B. 17°C Outdoor : D.B. 35 (95°F) W.B. 24 (75°F) Outdoor : D.B. 7 (45°F) W.B. 6 (43°F) Outdoor D.B. 46°C D.B. -5°C + D.B. 21°C, W.B. 15°C D.B. -20°C, W.B. -20°C 10 3. Guaranteed voltage 198~264V, 50Hz 4. Above data are based on the indicated voltage. Indoor unit Single phase 230V 50Hz Outdoor unit Single phase 230V 50Hz + If optional air protect guide installed. D.B.-15 Model name Cooling Indoor unit PEAD-RP100JA(L) Outdoor unit PUHZ-RP100VKA Capacity 34,100 42,700 47,800 kW 10.0(4.9-11.4) 12.5(5.5-14.0) 14.0(6.2-15.3) kW EER Energy label class SHF Capacity 3.86(3.84) 4.36(4.34) 3.24(3.26) 3.21(3.23) A A A 0.82 0.84 0.83 38,200 47,800 54,600 kW 11.2(4.5-14.0) 14.0(5.0-16.0) 16.0(5.7-18.0) kW 2.72 3.50 4.04 4.12 4.00 3.96 A A A - - - COP Energy label class Booster heater kW Phase : Cycle Hz 50 Voltage V 230 Breaker size Indoor unit 2.77(2.75) 3.61(3.64) Btu/h Total input Power supply PEAD-RP140JA(L) PUHZ-RP140VKA Btu/h Total input Heating PEAD-RP125JA(L) PUHZ-RP125VKA 1 A 32 40 Air flow CMM 24-29-34 29.5-35.5-42 32-39-46 (Low-Middle-High) CFM 847-1,024-1,201 1,042-1,253-1,483 1,130-1,377-1,624 External pressure Pa Sound level 35/50/70/100/150 dB(A) 29-34-38 33-36-40 34-38-43 (Low-Middle-High/50Pa) External finish Dimension Galvanized sheets W : mm 1,400 1,600 D : mm 732 H : mm 250 W : inch 55-1/8 D : inch H : inch Weight Field drain pipe O.D. Outdoor unit Air flow 9-7/8 kg 41(40) 43(42) 47(46) lbs 91(89) 95(93) 104(102) mm 32 inch 1-1/4 CMM 110 120 CFM 3,880 4,230 Sound level at cooling dB(A) 49 50 Sound level at heating dB(A) 51 52 External finish Dimension Ivory Munsell 3Y 7.8/1.1 W : mm 1,050 D : mm 330+30 H : mm 1,338 W : inch 41-5/16 D : inch 13 + 1-3/16 H : inch Weight Refrigerant pipe size Gas side O.D. NOTE: 116 116 119 lbs 256 256 262 15.88 inch 5/8 mm 9.52 inch 3/8 Height difference m Max. 30 Length m Max. 75 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27 (80°F) W.B. 19 (66°F) Heating Indoor : D.B. 20 (68°F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Upper limit Lower limit Upper limit Heating Lower limit Cooling 52-11/16 kg mm Liquid side O.D. Refrigerant pipe length 63 28-7/8 Indoor D.B. 35°C, W.B. 22.5°C D.B. 19°C, W.B. 15°C D.B. 28°C D.B. 17°C Outdoor : D.B. 35 (95°F) W.B. 24 (75°F) Outdoor : D.B. 7 (45°F) W.B. 6 (43°F) Outdoor D.B. 46 D.B. -5 + D.B. 21, W.B. 15 D.B. -20, W.B. -20 11 3. Guaranteed voltage 198~264V, 50Hz 4. Above data are based on the indicated voltage. Indoor unit Single phase 230V 50Hz Outdoor unit Single phase 230V 50Hz + If optional air protect guide installed. D.B.-15 Model name Cooling Indoor unit PEAD-RP100JA(L) Outdoor unit Btu/h PUHZ-RP100YKA 34,100 PEAD-RP125JA(L) PUHZ-RP125YKA 42,700 PEAD-RP140JA(L) PUHZ-RP140YKA 47,800 kW 10.0(4.9-11.4) 12.5(5.5-14.0) 14.0(6.2-15.3) kW 2.77(2.75) 3.86(3.84) 4.36(4.34) 3.61(3.64) 3.24(3.26) 3.21(3.23) A A A 0.82 0.84 0.83 Capacity Total input EER Energy label class SHF Heating Capacity Total input Btu/h 38,200 47,800 54,600 kW 11.2(4.5-14.0) 14.0(5.0-16.0) 16.0(5.7-18.0) kW 2.72 3.50 4.04 4.12 4.00 3.96 A A A - - - COP Energy label class Booster heater Power supply kW Phase : Cycle Hz 50 Voltage V 400 Breaker size Indoor unit 3 A 16 Air flow CMM 24-29-34 29.5-35.5-42 32-39-46 (Low-Middle-High) CFM 847-1,024-1,201 1,042-1,253-1,483 1,130-1,377-1,624 External pressure Sound level Pa 35/50/70/100/150 dB(A) 29-34-38 33-36-40 34-38-43 (Low-Middle-High/50Pa) External finish Dimension Galvanized sheets W : mm 1,400 1,600 D : mm 732 H : mm 250 W : inch 55-1/8 D : inch 63 28-7/8 H : inch Weight Field drain pipe O.D. Outdoor unit Air flow 9-7/8 kg 41(40) 43(42) 47(46) lbs 91(89) 95(93) 104(102) mm 32 inch 1-1/4 CMM 110 120 CFM 3,880 4,230 Sound level at cooling dB(A) 49 50 Sound level at heating dB(A) 51 52 External finish Dimension Weight Refrigerant pipe size Ivory Munsell 3Y 7.8/1.1 W : mm 1,050 D : mm 330+30 H : mm 1,338 W : inch 41-5/16 D : inch 13 + 1-3/16 H : inch kg 124 52-11/16 126 132 lbs 273 278 291 Gas side O.D. mm Liquid side O.D. Refrigerant pipe length NOTE: inch 5/8 mm 9.52 inch 3/8 Height difference m Max. 30 Length m Max. 75 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27 (80°F) W.B. 19 (66°F) Heating Indoor : D.B. 20 (68°F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Upper limit Lower limit Upper limit Heating Lower limit Cooling 15.88 Indoor D.B. 35°C, W.B. 22.5°C D.B. 19°C, W.B. 15°C D.B. 28°C D.B. 17°C Outdoor : D.B. 35 (95°F) W.B. 24 (75°F) Outdoor : D.B. 7 (45°F) W.B. 6 (43°F) Outdoor D.B. 46°C D.B. -5°C + D.B. 21°C, W.B. 15°C D.B. -20°C, W.B. -20°C 12 3. Guaranteed voltage Indoor unit 198~264V, 50Hz Outdoor unit 342~457V, 50Hz 4. Above data are based on the indicated voltage. Indoor unit Single phase 230V 50Hz Outdoor unit 3 phase 400V 50Hz + If optional air protect guide installed. D.B.-15 Model name Indoor unit Outdoor unit Cooling Capacity 65,000 75,000 kW 19.0(9.0-22.4) 22.0(11.2-28.0) kW 6.70 8.34 2.84 2.64 EER Energy label class SHF Capacity - 0.81 0.86 76,400 92,000 kW 22.4(9.5-25.0) 27.0(12.5-31.5) kW 6.50 8.20 3.45 3.29 - - COP Energy label class Booster heater kW - - Phase : Cycle Hz 50 Voltage V 400 Breaker size Indoor unit Btu/h Total input Power supply PEA-RP250GA PUHZ-RP250YKA Btu/h Total input Heating PEA-RP200GA PUHZ-RP200YKA 3 A Indoor 15 / Outdoor 32 Air flow CMM 52-65 64-80 (Low-High) CFM 1835-2295 2260-2825 External pressure Sound level Pa 150 dB(A) 48-51 W : mm 1400 49-52 (Low-High) External finish Dimension Galvanized steel 1600 D : mm 634 H : mm W : inch 400 55-1/8 63 D : inch 25 H : inch Weight 15-3/4 kg 70 77 lbs 155 170 Unit drain pipe Outdoor unit Air flow R1 CMM 140 CFM 4,940 Sound level at cooling dB(A) 58 Sound level at heating dB(A) 59 External finish Dimension Ivory Munsell 3Y 7.8/1.1 W : mm 1,050 D : mm 330+30 H : mm 1,338 W : inch 41-5/16 D : inch 13 + 1-3/16 H : inch Weight Refrigerant pipe size Gas side O.D. 52-11/16 kg 135 lbs 297 141 311 mm 25.4 inch Liquid side O.D. Refrigerant pipe length NOTE: 9.52 inch 3/8 12.7 1/2 Height difference m Max. 30 Length m Max. 100 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27 (80°F) W.B. 19 (66°F) Heating Indoor : D.B. 20 (68°F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Upper limit Lower limit Upper limit Heating Lower limit Cooling 1 mm Indoor D.B. 35°C, W.B. 22.5°C D.B. 19°C, W.B. 15°C D.B. 28°C D.B. 17°C Outdoor : D.B. 35 (95°F) W.B. 24 (75°F) Outdoor : D.B. 7 (45°F) W.B. 6 (43°F) Outdoor D.B. 46°C D.B. -5°C +1 D.B. 21°C, W.B. 15°C D.B. -20°C, W.B. -20°C 13 3. Guaranteed voltage 342~457V, 50Hz 4. Above data are based on the indicated voltage. Indoor unit 3 phase 400V 50Hz Outdoor unit 3 phase 400V 50Hz +1. If optional air protect guide is installed : D.B.-15 Model name Indoor unit Outdoor unit Cooling Capacity Total input PEA-RP400GA PEA-RP500GA PUHZ-RP200YKA%2 PUHZ-RP250YKA%2 Btu/h 130,000 150,000 kW 38.0(18.0-44.8) 44.0(22.4-56.0) kW 12.95 17.16 2.93 2.56 EER Energy label class SHF Heating Capacity Total input 153,000 184,000 44.8(18.0-50.0) 54.0(25.0-63.0) kW 12.55 16.88 3.57 3.20 - - kW - - Phase : Cycle Hz 50 Voltage V 400 Breaker size Indoor unit 0.77 kW Energy label class Power supply - 0.75 Btu/h COP Booster heater - 3 A Indoor 15 / Outdoor 32 % 2 Air flow CMM 120 160 (High) CFM 4240 5650 External pressure Sound level Pa 150 dB(A) 52 53 (High) External finish Dimension Galvanized steel W : mm 1,947 D : mm 764 H : mm 595 W : inch 79-11/16 D : inch 30-1/8 H : inch 23-7/16 Weight kg 130 133 lbs 286 293 Unit drain pipe Outdoor unit (Per 1 outdoor unit) R1 CMM 140 CFM 4,940 Sound level at cooling dB(A) 58 Sound level at heating dB(A) Air flow 59 Ivory Munsell 3Y 7.8/1.1 External finish Dimension W : mm 1,050 D : mm 330+30 H : mm 1,338 W : inch 41-5/16 D : inch 13 + 1-3/16 52-11/16 H : inch Weight Refrigerant pipe size Gas side O.D. kg 135 lbs 297 mm 141 311 25.4 % 2 inch Liquid side O.D. Refrigerant pipe length NOTE: 9.52 % 2 inch 3/8 % 2 12.7 % 2 1/2 % 2 Height difference m Max. 30 Length m Max. 100 (per 1 outdoor unit) 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27 (80°F) W.B. 19 (66°F) Heating Indoor : D.B. 20 (68°F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Upper limit Lower limit Upper limit Heating Lower limit Cooling 1%2 mm Indoor D.B. 35°C, W.B. 22.5°C D.B. 19°C, W.B. 15°C D.B. 28°C D.B. 17°C Outdoor : D.B. 35 (95°F) W.B. 24 (75°F) Outdoor : D.B. 7 (45°F) W.B. 6 (43°F) Outdoor D.B. 46°C D.B. -5°C +1 D.B. 21°C, W.B. 15°C D.B. -20°C, W.B. -20°C 14 3. Guaranteed voltage 342~457V, 50Hz 4. Above data are based on the indicated voltage. Indoor unit 3 phase 400V 50Hz Outdoor unit 3 phase 400V 50Hz +1. If optional air protect guide is installed : D.B.-15 2-3. WALL MOUNTED TYPE Model name Indoor unit Outdoor unit Cooling Capacity Total input 12,300 15,700 kW 3.6(1.6-4.5) 4.6(2.3-5.6) kW Energy label class SHF Capacity Total input 14,000 17,100 5.0(2.5-7.3) kW 1.13 1.38 3.63 3.62 A A Hz 50 Voltage V 230 A 16 CMM 9-10.5-12 (Low-Middle-High) CFM 320-370-425 External pressure Pa 0 dB(A) 36-40-43 White Munsell 1.0Y 9.2/0.2 Weight Field drain pipe I.D. Air flow W : mm 898 D : mm 249 H : mm 295 W : inch 35-3/8 D : inch 9-13/16 H : inch 11-5/8 kg 13 lbs 29 mm 16 inch 5/8 CMM 35 CFM 1,240 Sound level at cooling dB(A) 44 Sound level at heating dB(A) External finish Weight Gas side O.D. Liquid side O.D. W : mm 800 D : mm 300+23 H : mm 600 W : inch 31-1/2 D : inch 11-13/16 + 7/8 H : inch 23-5/8 kg 42 lbs 93 mm 12.7 inch 1/2 mm 6.35 inch 1/4 Height difference m Max. 30 Length m Max. 50 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27 (80°F) W.B. 19 (66°F) Heating Indoor : D.B. 20 (68°F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Upper limit Lower limit Upper limit Heating Lower limit 46 Ivory Munsell 3Y 7.8/1.1 Dimension Cooling 1 Air flow Dimension NOTE: - Cycle External finish Refrigerant pipe length - : (Low-Middle-High) Refrigerant pipe size A 0.72 Phase Sound level Outdoor unit A 0.81 4.1(1.6-5.2) kW Breaker size Indoor unit 1.43 3.22 kW Energy label class Power supply 0.98 3.67 Btu/h COP Booster heater PKA-RP50HAL PUHZ-RP50VHA4 Btu/h EER Heating PKA-RP35HAL PUHZ-RP35VHA4 Indoor D.B. 35°C, W.B. 22.5°C D.B. 19°C, W.B. 15°C D.B. 28°C D.B. 17°C Outdoor : D.B. 35 (95°F) W.B. 24 (75°F) Outdoor : D.B. 7 (45°F) W.B. 6 (43°F) Outdoor D.B. 46°C D.B. -5°C + D.B. 21°C, W.B. 15°C D.B. -11°C, W.B. -12°C 15 3. Guaranteed voltage 198~264V, 50Hz 4. Above data are based on the indicated voltage. Indoor unit Single phase 230V 50Hz Outdoor unit Single phase 230V 50Hz + If optional air protect guide installed. D.B.-15 Model name Indoor unit Outdoor unit Cooling Capacity Total input 20,500 24,200 34,100 34,100 7.1(3.3-8.1) 10.0(4.9-11.4) 10.0(4.9-11.4) kW 1.54 1.96 2.90 2.90 3.90 3.62 3.45 3.45 A A A 0.78 0.73 0.73 23,900 27,300 38,200 38,200 kW 7.0(2.8-8.2) 8.0(3.5-10.2) 11.2(4.5-14.0) 11.2(4.5-14.0) kW 1.76 2.13 3.10 3.10 3.98 3.76 3.61 3.61 A A A A - - - 3 Energy label class Booster heater Phase kW Cycle Hz 50 50 Voltage V 230 400 Breaker size Indoor unit A 0.86 Btu/h COP Power supply PKA-RP100KAL PUHZ-RP100YKA 6.0(2.7-6.7) SHF Total input PKA-RP100KAL PUHZ-RP100VKA kW Energy label class Capacity PKA-RP71KAL PUHZ-RP71VHA4 Btu/h EER Heating PKA-RP60KAL PUHZ-RP60VHA4 1 : 25 A 25 Air flow (Low-Middle-High) CMM 18-20-22 CFM 635-705-780 External pressure Pa Sound level (Low-Middle-High) Weight Field drain pipe I.D. Outdoor unit Air flow dB(A) Munsell 1.0Y 9.2/0.2 W : mm 1,170 D : mm 295 H : mm 365 W : inch 46-1/16 D : inch 11-5/8 H : inch 14-3/8 kg 21 lbs 46 mm 16 inch 5/8 CMM 60 110 CFM 2,120 3,880 dB(A) 47 49 Sound level at heating dB(A) 48 51 W : mm 950 Ivory Munsell 3Y 7.8/1.1 D : mm Weight Gas side O.D. Liquid side O.D. 1,050 330+30 H : mm 943 1,338 W : inch 37-3/8 41-5/16 D : inch 13 + 1-3/16 H : inch 37-1/8 kg 67 116 124 lbs 148 256 273 mm 52-11/16 15.88 inch 5/8 mm 9.52 inch NOTE: 41-45-49 Sound level at cooling Dimension Refrigerant pipe length 705-810-920 39-42-45 External finish Refrigerant pipe size 16 20-23-26 0 External finish Dimension 32 3/8 Height difference m Max. 30 Max. 30 Length m Max. 50 Max. 75 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27 (80°F) W.B. 19 (66°F) Heating Indoor : D.B. 20 (68°F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Upper limit Cooling Lower limit Upper limit Heating Lower limit Indoor D.B. 35°C, W.B. 22.5°C D.B. 19°C, W.B. 15°C D.B. 28°C D.B. 17°C Outdoor : D.B. 35 (95°F) W.B. 24 (75°F) Outdoor : D.B. 7 (45°F) W.B. 6 (43°F) Outdoor D.B. 46°C D.B. -5°C + D.B. 21°C, W.B. 15°C D.B. -20°C, W.B. -20°C 16 3. Guaranteed voltage 198~264V, 50Hz (RP100Y: 342~457V, 50Hz) 4. Above data are based on the indicated voltage. Indoor unit Single phase 230V 50Hz Outdoor unit V: Single phase 230V 50Hz Y: 3phase 400V 50Hz + If optional air protect guide installed. D.B.-15 2-4. CEILING SUSPENDED TYPE Model name Indoor unit Outdoor unit Cooling Capacity Total input PCA-RP50KA PCA-RP60KA PCA-RP71KA PUHZ-RP50VHA4 PUHZ-RP60VHA4 PUHZ-RP71VHA4 Btu/h 17,100 20,500 24,200 kW 5.0(2.3-5.6) 6.0(2.7-6.7) 7.1(3.3-8.1) kW 1.56 1.50 1.96 3.21 4.00 3.62 A A A 0.79 0.81 0.76 EER Energy label class SHF Heating Capacity Total input Btu/h 18,800 23,900 27,300 kW 5.5(2.5-6.6) 7.0(2.8-8.2) 8.0(3.5-10.2) kW 1.52 1.94 2.21 3.62 3.61 3.62 A A A - - - COP Energy label class Booster heater Power supply kW Phase : Cycle Hz 50 Voltage V 230 Breaker size Indoor unit Air flow (Low-Medium2-Medium1-High) External pressure 1 A 16 CMM 10-11-13-15 15-16-17-19 16-17-18-20 CFM 355-390-460-530 530-565-600-670 565-600-635-705 Pa Sound level (Low-Medium2-Medium1-High) 0 dB(A) 32-34-37-40 W : mm 960 External finish Dimension H : mm 230 Field drain pipe O.D. 9-1/16 kg 25 lbs 55 mm 1 35 60 CFM 1,240 2,120 Sound level at cooling dB(A) 44 47 Sound level at heating dB(A) 46 48 W : mm 800 330+23 Dimension Ivory Munsell 3Y 7.8/1.1 D : mm 950 330+30 H : mm 600 943 W : inch 37-3/8 D : inch 31-1/2 13 + 7/8 13 + 1-3/16 H : inch 23-5/8 37-1/8 kg 42 67 lbs 93 148 15.88 Weight Gas side O.D. Liquid side O.D. mm 12.7 inch 1/2 5/8 mm 6.35 9.52 inch 1/4 3/8 Height difference m Max. 30 Max. 30 Length m Max. 50 Max. 50 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27 (80°F) W.B. 19 (66°F) Heating Indoor : D.B. 20 (68°F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Upper limit Lower limit Upper limit Heating Lower limit Cooling 71 CMM External finish NOTE: 32 26 inch Air flow 50-3/8 26-3/4 H : inch Weight 1,280 37-13/16 D : inch Refrigerant pipe length 35-37-39-41 680 W : inch Refrigerant pipe size 33-35-37-40 White Munsell 6.4Y 8.9/0.4 D : mm Outdoor unit 25 Indoor D.B. 35°C, W.B. 22.5°C D.B. 19°C, W.B. 15°C D.B. 28°C D.B. 17°C Outdoor : D.B. 35 (95°F) W.B. 24 (75°F) Outdoor : D.B. 7 (45°F) W.B. 6 (43°F) Outdoor D.B. 46°C D.B. -5°C +1 D.B. 21°C, W.B. 15°C D.B. -11°C, W.B. -12°C +2 17 3. Guaranteed voltage 198~264V, 50Hz 4. Above data are based on the indicated voltage. Indoor unit Single phase 230V 50Hz Outdoor unit Single phase 230V 50Hz +1. If optional air protect guide installed. D.B.-15°C +2. For RP60/71 D.B. -20°C, W.B. -20°C Model name Indoor unit Outdoor unit Cooling Capacity PCA-RP100KA PUHZ-RP100VKA 34,100 42,700 47,800 kW 10.0(4.9-11.4) 12.5(5.5-14.0) 14.0(6.2-15.3) kW 2.63 3.88 4.36 3.80 3.22 3.21 A A A 0.77 0.72 0.71 EER Energy label class SHF Capacity Btu/h 38,200 47,800 54,600 kW 11.2(4.5-14.0) 14.0(5.0-16.0) 16.0(5.7-18.0) kW 3.02 3.88 4.43 3.71 3.61 3.61 A A A - - - Total input COP Energy label class Booster heater Power supply kW Phase : Cycle Hz 50 Voltage V 230 Breaker size Indoor unit 1 A 32 40 Air flow CMM 22-24-26-28 23-25-27-29 24-26-29-32 (Low-Medium2-Medium1-High) CFM 775-850-920-990 810-885-955-1,025 850-920-1,025-1,130 External pressure Sound level (Low-Medium2-Medium1-High) Pa 0 dB(A) 37-39-41-43 External finish Dimension 39-41-43-45 1,600 D : mm 680 H : mm 230 W : inch 63 D : inch 26-3/4 H : inch Field drain pipe O.D. 9-1/16 kg 36 38 39 lbs 79 84 86 mm 26 inch 1 CMM 110 120 CFM 3,880 4,230 Sound level at cooling dB(A) 49 50 Sound level at heating dB(A) 51 Air flow External finish Dimension 52 Ivory Munsell 3Y 7.8/1.1 W : mm 1,050 D : mm 330+30 H : mm 1,338 W : inch 41-5/16 D : inch 13 + 1-3/16 H : inch Weight Refrigerant pipe size Gas side O.D. NOTE: 116 119 lbs 256 262 15.88 inch 5/8 mm 9.52 inch 3/8 Height difference m Max. 30 Length m Max. 75 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27 (80°F) W.B. 19 (66°F) Heating Indoor : D.B. 20 (68°F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Upper limit Lower limit Upper limit Heating Lower limit Cooling 52-11/16 kg mm Liquid side O.D. Refrigerant pipe length 41-43-45-48 White Munsell 6.4Y 8.9/0.4 W : mm Weight Outdoor unit PCA-RP140KA PUHZ-RP140VKA Btu/h Total input Heating PCA-RP125KA PUHZ-RP125VKA Indoor D.B. 35°C, W.B. 22.5°C D.B. 19°C, W.B. 15°C D.B. 28°C D.B. 17°C Outdoor : D.B. 35 (95°F) W.B. 24 (75°F) Outdoor : D.B. 7 (45°F) W.B. 6 (43°F) Outdoor D.B. 46 D.B. -5 + D.B. 21, W.B. 15 D.B. -20, W.B. -20 18 3. Guaranteed voltage 198~264V, 50Hz 4. Above data are based on the indicated voltage. Indoor unit Single phase 230V 50Hz Outdoor unit Single phase 230V 50Hz + If optional air protect guide installed. D.B.-15 Model name Indoor unit PCA-RP100KA PUHZ-RP100YKA Outdoor unit Cooling Capacity 34,100 42,700 47,800 kW 10.0(4.9-11.4) 12.5(5.5-14.0) 14.0(6.2-15.3) kW 2.63 3.88 4.36 3.80 3.22 3.21 A A A 0.77 0.72 0.71 EER Energy label class SHF Capacity Btu/h 38,200 47,800 54,600 kW 11.2(4.5-14.0) 14.0(5.0-16.0) 16.0(5.7-18.0) kW 3.02 3.88 4.43 3.71 3.61 3.61 A A A - - - Total input COP Energy label class Booster heater Power supply kW Phase : Cycle Hz 50 Voltage V 400 16 Breaker size Indoor unit 3 A Air flow CMM 22-24-26-28 23-25-27-29 24-26-29-32 (Low-Medium2-Medium1-High) CFM 775-850-920-990 810-885-955-1,025 850-920-1,025-1,130 External pressure Sound level (Low-Medium2-Medium1-High) 0 Pa dB(A) 37-39-41-43 Dimension 39-41-43-45 W : mm 1,600 D : mm 680 H : mm 230 W : inch 63 D : inch 26-3/4 9-1/16 H : inch Weight Field drain pipe O.D. kg 36 38 39 lbs 79 84 86 26 mm 1 inch Air flow CMM 110 120 4,230 50 CFM 3,880 Sound level at cooling dB(A) 49 Sound level at heating dB(A) 51 52 Ivory Munsell 3Y 7.8/1.1 External finish Dimension W : mm 1,050 D : mm 330+30 H : mm 1,338 W : inch 41-5/16 D : inch 13 + 1-3/16 52-11/16 H : inch Weight Refrigerant pipe size Gas side O.D. NOTE: 124 126 132 lbs 273 278 291 15.88 inch 5/8 mm 9.52 inch 3/8 Height difference m Max. 30 Length m Max. 75 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27 (80°F) W.B. 19 (66°F) Heating Indoor : D.B. 20 (68°F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Upper limit Lower limit Upper limit Heating Lower limit Cooling kg mm Liquid side O.D. Refrigerant pipe length Indoor D.B. 35°C, W.B. 22.5°C D.B. 19°C, W.B. 15°C D.B. 28°C D.B. 17°C 41-43-45-48 White Munsell 6.4Y 8.9/0.4 External finish Outdoor unit PCA-RP140KA PUHZ-RP140YKA Btu/h Total input Heating PCA-RP125KA PUHZ-RP125YKA Outdoor : D.B. 35 (95°F) W.B. 24 (75°F) Outdoor : D.B. 7 (45°F) W.B. 6 (43°F) Outdoor D.B. 46°C D.B. -5°C + D.B. 21°C, W.B. 15°C D.B. -20°C, W.B. -20°C 19 3. Guaranteed voltage Indoor unit 198~264V, 50Hz Outdoor unit 342~457V, 50Hz 4. Above data are based on the indicated voltage. Indoor unit Single phase 230V 50Hz Outdoor unit 3 phase 400V 50Hz + If optional air protect guide installed. D.B.-15 Model name Indoor unit PCA-RP71HA PUHZ-RP71VHA4 Outdoor unit Cooling Capacity Total input 24,200 42,700 42,700 kW 7.1(3.3-8.1) 12.5(5.5-14.0) 12.5(5.5-14.0) kW 2.21 3.88 3.88 3.21 3.22 3.22 A A A 0.74 0.77 0.77 Energy label class SHF Capacity Total input Btu/h 25,900 47,100 47,100 kW 7.6(3.5-10.2) 13.8(5.0-16.0) 13.8(5.0-16.0) kW 2.23 4.05 4.05 3.41 3.41 3.41 B B B - - COP Energy label class Booster heater Power supply kW : Cycle Hz 50 50 Voltage V 230 400 1 A CMM 17-19 (Low-High) CFM 600-670 Sound level (Low-High) 0 dB(A) 34-38 W : mm 1136 44-50 Stainless steel 1520 650 H : mm W : inch 280 44-3/4 59-7/8 D : inch 25-5/8 H : inch Field drain pipe O.D. 1,060-1,350 Pa D : mm Weight 16 30-38 External finish Dimension 3 25 Air flow External pressure 11 kg 41 56 lbs 90 124 mm 26 inch Outdoor unit Air flow 1 CMM 60 120 CFM 2,120 4,230 Sound level at cooling dB(A) 47 50 Sound level at heating dB(A) 48 52 W : mm 950 1,050 D : mm 330+30 330+30 External finish Dimension Weight Refrigerant pipe size Gas side O.D. Liquid side O.D. Refrigerant pipe length NOTE: Ivory Munsell 3Y 7.8/1.1 H : mm 943 1,338 W : inch 37-3/8 41-5/16 D : inch 13 + 1-3/16 13 + 1-3/16 H : inch 37-1/8 kg 67 116 lbs 148 256 mm 15.88 52-11/16 126 278 15.88 inch 5/8 5/8 mm 9.52 9.52 inch 3/8 3/8 Height difference m Max. 30 Max. 30 Length m Max. 50 Max. 75 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27 (80°F) W.B. 19 (66°F) Heating Indoor : D.B. 20 (68°F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Upper limit Lower limit Upper limit Heating Lower limit Cooling - Phase Breaker size Indoor unit PCA-RP125HA PUHZ-RP125YKA Btu/h EER Heating PCA-RP125HA PUHZ-RP125VKA Indoor D.B. 35°C, W.B. 22.5°C D.B. 19°C, W.B. 15°C D.B. 28°C D.B. 17°C Outdoor : D.B. 35 (95°F) W.B. 24 (75°F) Outdoor : D.B. 7 (45°F) W.B. 6 (43°F) Outdoor D.B. 46°C D.B. -5°C + D.B. 21°C, W.B. 15°C D.B. -20°C, W.B. -20°C 20 3. Guaranteed voltage 198~264V, 50Hz (RP125Y : 342~457V, 50Hz) 4. Above data are based on the indicated voltage. Indoor unit Single phase 230V 50Hz Outdoor unit V: Single phase 230V 50Hz, Y: 3 phase 400V 50Hz + If optional air protect guide installed. D.B.-15 2-5. FLOOR STANDING TYPE Model name Indoor unit PSA-RP71GA Outdoor unit Cooling PUHZ-RP71VHA4 Capacity Total input Btu/h 24,200 kW 7.1(3.3-8.1) kW 2.20 EER 3.23 Energy label class A SHF Heating 0.73 Capacity Total input Btu/h 25,900 kW 7.6(3.5-10.2) kW 2.23 COP 3.41 Energy label class B Booster heater Power supply kW - Phase : 1 Cycle Hz 50 Voltage V 230 Breaker size Indoor unit A 25 Air flow CMM 15-18 (Low-High) CFM 530-635 Pa 0 dB(A) 40-45 External pressure Sound level (Low-High) External finish White Munsell 0.70Y 8.59/0.97 Dimension W : mm Weight Field drain pipe I.D. Outdoor unit Air flow 270 H : mm 1,900 W : inch 23-5/8 D : inch 10-5/8 H : inch 74-13/16 kg 43 lbs 98 mm 20 inch 13/16 CMM 60 CFM 2,120 Sound level at cooling dB(A) 47 Sound level at heating dB(A) External finish Weight Gas side O.D. Liquid side O.D. Refrigerant pipe length NOTE: Upper limit Lower limit Upper limit Heating Lower limit W : mm 950 D : mm 330+30 H : mm 943 W : inch 37-3/8 D : inch 13 + 1-3/16 H : inch 37-1/8 kg 67 lbs 148 mm 15.88 inch 5/8 mm 9.52 inch 3/8 Height difference m Max. 30 Length m Max. 50 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27 (80°F) W.B. 19 (66°F) Heating Indoor : D.B. 20 (68°F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Cooling 48 Ivory Munsell 3Y 7.8/1.1 Dimension Refrigerant pipe size 600 D : mm Indoor D.B. 35°C, W.B. 22.5°C D.B. 19°C, W.B. 15°C D.B. 28°C D.B. 17°C Outdoor : D.B. 35 (95°F) W.B. 24 (75°F) Outdoor : D.B. 7 (45°F) W.B. 6 (43°F) Outdoor D.B. 46°C D.B. -5°C + D.B. 21°C, W.B. 15°C D.B. -20°C, W.B. -20°C 21 3. Guaranteed voltage 198~264V, 50Hz 4. Above data are based on the indicated voltage. Indoor unit Single phase 230V 50Hz Outdoor unit Single phase 230V 50Hz + If optional air protect guide installed. D.B.-15 Model name Indoor unit PSA-RP100GA PUHZ-RP100VKA Outdoor unit Cooling Capacity 34,100 42,300 47,100 kW 10.0(4.9-11.4) 12.4(5.5-14.0) 13.8(6.2-15.3) kW EER Energy label class SHF Capacity 4.12 4.91 3.01 2.81 A B C 0.81 0.75 0.74 38,200 47,800 54,600 kW 11.2(4.5-14.0) 14.0(5.0-16.0) 16.0(5.7-18.0) kW 3.28 4.11 4.97 3.41 3.41 3.22 B B C - - - COP Energy label class Booster heater kW Phase : Cycle Hz 50 Voltage V 230 Breaker size Indoor unit 2.99 3.34 Btu/h Total input Power supply 1 A 32 CMM 24-31 26-33 27-35 (Low-High) CFM 850-1060 920-1165 955-1240 Sound level (Low-High) Pa 0 dB(A) 44-49 External finish Dimension 46-51 600 D : mm 350 H : mm 1,900 W : inch 23-5/8 D : inch 13-3/4 H : inch Field drain pipe I.D. 74-13/16 kg 51 53 lbs 112 117 mm 20 inch 13/16 CMM 110 120 CFM 3,880 4,230 Sound level at cooling dB(A) 49 50 Sound level at heating dB(A) 51 Air flow External finish Dimension 52 Ivory Munsell 3Y 7.8/1.1 W : mm 1,050 D : mm 330+30 H : mm 1,338 W : inch 41-5/16 D : inch 13 + 1-3/16 H : inch Weight Gas side O.D. NOTE: 116 119 lbs 256 262 15.88 inch 5/8 mm 9.52 inch 3/8 Height difference m Max. 30 Length m Max. 75 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27 (80°F) W.B. 19 (66°F) Heating Indoor : D.B. 20 (68°F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Upper limit Lower limit Upper limit Heating Lower limit Cooling 52-11/16 kg mm Liquid side O.D. Refrigerant pipe length 47-52 White Munsell 0.70Y 8.59/0.97 W : mm Weight Refrigerant pipe size 40 Air flow External pressure Outdoor unit PSA-RP140GA PUHZ-RP140VKA Btu/h Total input Heating PSA-RP125GA PUHZ-RP125VKA Indoor D.B. 35°C, W.B. 22.5°C D.B. 19°C, W.B. 15°C D.B. 28°C D.B. 17°C Outdoor : D.B. 35 (95°F) W.B. 24 (75°F) Outdoor : D.B. 7 (45°F) W.B. 6 (43°F) Outdoor D.B. 46 D.B. -5 + D.B. 21, W.B. 15 D.B. -20, W.B. -20 22 3. Guaranteed voltage 198~264V, 50Hz 4. Above data are based on the indicated voltage. Indoor unit Single phase 230V 50Hz Outdoor unit Single phase 230V 50Hz + If optional air protect guide installed. D.B.-15 Model name Indoor unit Outdoor unit Cooling Capacity PSA-RP100GA PSA-RP125GA PSA-RP140GA PUHZ-RP100YKA PUHZ-RP125YKA PUHZ-RP140YKA Btu/h 34,100 42,300 47,100 kW 10.0(4.9-11.4) 12.4(5.5-14.0) 13.8(6.2-15.3) kW 2.99 4.12 4.91 3.34 3.01 2.81 A B C 0.81 0.75 0.74 Total input EER Energy label class SHF Heating Capacity Btu/h 38,200 47,800 54,600 kW 11.2(4.5-14.0) 14.0(5.0-16.0) 16.0(5.7-18.0) kW 3.28 4.11 4.97 3.41 3.41 3.22 B B C - - - Total input COP Energy label class Booster heater Power supply kW Phase : Cycle Hz 50 Voltage V 400 Breaker size Indoor unit 3 A 16 Air flow CMM 24-31 26-33 27-35 (Low-High) CFM 850-1,060 920-1,165 955-1,240 External pressure Sound level (Low-High) Pa 0 dB(A) 44-49 External finish Dimension 600 D : mm 350 H : mm 1,900 W : inch 23-5/8 D : inch 13-3/4 H : inch Field drain pipe I.D. 74-13/16 kg 51 51 53 lbs 112 112 117 mm 20 inch 13/16 CMM 110 120 CFM 3,880 4,230 Sound level at cooling dB(A) 49 50 Sound level at heating dB(A) 51 Air flow 52 External finish Dimension Ivory Munsell 3Y 7.8/1.1 W : mm 1,050 D : mm 330+30 H : mm 1,338 W : inch 41-5/16 D : inch 13 + 1-3/16 H : inch Weight Refrigerant pipe size Gas side O.D. NOTE: 52-11/16 kg 124 126 132 lbs 273 278 291 mm Liquid side O.D. Refrigerant pipe length 47-52 White Munsell 0.70Y 8.59/0.97 W : mm Weight Outdoor unit 46-51 15.88 inch 5/8 mm 9.52 inch 3/8 Height difference m Max. 30 Length m Max. 75 1. Rating conditions (ISO T1) Cooling Indoor : D.B. 27 (80°F) W.B. 19 (66°F) Heating Indoor : D.B. 20 (68°F) Refrigerant piping length (one way) : 5m (16ft.) 2. Guaranteed operating range Upper limit Cooling Lower limit Upper limit Heating Lower limit Indoor D.B. 35°C, W.B. 22.5°C D.B. 19°C, W.B. 15°C D.B. 28°C D.B. 17°C Outdoor : D.B. 35 (95°F) W.B. 24 (75°F) Outdoor : D.B. 7 (45°F) W.B. 6 (43°F) Outdoor D.B. 46°C D.B. -5°C + D.B. 21°C, W.B. 15°C D.B. -20°C, W.B. -20°C 23 3. Guaranteed voltage Indoor unit 198~264V, 50Hz Outdoor unit 342~457V, 50Hz 4. Above data are based on the indicated voltage. Indoor unit Single phase 230V 50Hz Outdoor unit 3 phase 400V 50Hz + If optional air protect guide installed. D.B.-15 OUTLINES AND DIMENSIONS INDOOR UNIT PLA-RP35BA PLA-RP100BA PLA-RP71BA2 Unit : mm PLA-RP50BA PLA-RP125BA PLA-RP100BA3 Ceiling hole PLA-RP125BA2 PLA-RP140BA2 20~45 860~910 810 Suspension bolt pitch Detail connecting of branch duct(Both aspects) 90 100 100 90 Cut out hole 860~910 620 605 +35 -5 Indoor power supply terminal block(Option part) Ceiling hole + Suspension bolt pitch 840 Branch duct hole 155 Remote controller terminal block Indoor unit/Outdoor unit connecting terminal block Branch duct hole 350 :175 167 70 160 (7.5) 160 100 Fresh air intake hole PLA-RP71BA 130 20~45 PLA-RP60BA 20~45 3 + 14-:2.8 Burring hole pitch Burring hole :150 Detail drawing of fresh air intake hole (7.5) 24 160 D C 90 150 Cut out hole Burring hole 840 60 284 ( Connected the attached Drain pipe connected to VP-25 flexible pipe or socket. 377 + Control wire entry B Cut out hole :100 Keep approximately 10 to 15mm space between unit ceiling and ceiling slab. + Ceiling + In case of standard grille : PLP-6BA / PLP-6BAMD Ceiling 35 Power supply wire, Indoor unit/Outdoor unit connecting wire entry + 190 156 105 + + + 17 +50 Suspension bolt lower edge 140 + 50~70 170 A 2 ) 158 1 Burring hole pitch :125 120 120 160 Suspension bolt M10 or W3/8 3-:2.8 20~45 187.5 Grille 597 Drain hole Drain pump clean hole and Drain emergency drainage hole M 597 Auto vane (Air outlet) switch<Cooling>and Emergency Up/Down switch<Up> Emergency operation switch<Heating>and Emergency Up/Down switch<Down> Air intake hole Air outlet hole 500 950 M In case of auto-grille : PLP-6BAJ In case of wireless remote controller : PLP-6BALM Auto grille Air intake grille up/down discharge Emergency operation Air intake grille Receiver M 83 M 36 500 83 36 Indoor unit 1500mm or more 1000mm or more Indoor unit 3000mm or more Obstacle Floor Air intake grille Vane motor 950 Grille DEFROST/STAND BY lamp Operation lamp Air outlet hole Ceiling Ceiling L.L Filter 1800mm or more from floor For high attachment Note 1. Please choose the grille from a standard grille, auto-grille. 2. As for drain pipe, please use VP-25(O.D. :32 PVC TUBE). Drain pump is included. Max. lifting height is 850mm from the ceiling. 3. As for suspension bolt, please use M10 or W3/8. (Procured at local site) 4. Electrical box may be removed for the service purpose. Make sure to slack the electrical wire little bit for control/ power wires connection. 5. The height of the indoor unit is able to be adjusted with the grille attached. 6. For the installation of the optional high efficiency filter or optional multi-functional casement. 1) Requires E or more space between transom and ceiling for the installation. 2) Add 135 mm to the dimensions + marked on the figure. 3) The optional high efficiency filter must be used jointly with optional multi-functional casement. 7. When installing the branch ducts, be sure to insulate adequately. Otherwise condensation and dripping may occur. (It becomes the cause of dew drops/water dew.) 8. As for necessary installation/service space, please refer to the left figure. Models PLA-RP35/50BA PLA-RP60BA PLA-RP71BA PLA-RP71BA2 PLA-RP100,125BA PLA-RP100BA3 PLA-RP125,140BA2 24 1 2 Refrigerant pipe ···:6.35 Flared connection ···1/4 inch Refrigerant pipe :6.35 / :9.52 Flared connection 1/4 inch/3/8 inch (compatible) Refrigerant pipe ···:12.7 Flared connection ···1/2 inch Refrigerant pipe ···:9.52 Flared connection ···3/8 inch A B C D E 80 74 241 258 87 400 Refrigerant pipe ···:15.88 Flared connection ···5/8 inch 281 298 85 77 440 Max. 4.0m Air intake hole Unit : mm PEAD-RP35, 50, 60, 71, 100, 125, 140JA 2xE-:2.9 Suspension bolt hole 4-14x30 Slot 18 Air inlet 210 G Air outlet A B(Suspension bolt pitch) C D (Duct) 100x(E-1)=F 15 643 (Suspension bolt pitch) 32 238 10 Terminal block (Remote controller transmission line) 175±5mm (Actual length) 217 250 Control box 2×2-:2.9 136 67 356 NOTE 1. Use M10 screw for the Suspension bolt (field supply). 2. Keep the service space for the maintenance at the bottom. 3. This chart indicates for PEAD-RP60•71•100•125•140JA models,which have 2 fans. PEAD-RP35•50JA models have 1 fan. 4. In case that the inlet duct is used, remove the air filter (supplied with the unit), then install the filter (field supply) at suction side. Drain pipe(O.D.:32) Terminal block (Spontaneous draining) (Indoor/Outdoor connecting line) Model A PEAD-RP35,50JA 900 PEAD-RP60,71JA PEAD-RP100,125JA PEAD-RP140JA 6 D E F G 954 1000 860 9 800 858 B C 1100 1154 1200 1060 1400 1454 1500 1360 1600 1654 1700 1560 11 1000 1058 14 1300 1358 16 1500 1558 J Gas pipe Liquid pipe :12.7 :6.35 :15.88 :9.52 Kx(L-1)=M J K More than 20mm Ceiling surface 112 112 N-:2.9 More than 10mm Drain hose (I.D.:32) <accessory> 11 1 Refrigerant piping Flare connection (gas) Less than 300mm Less than 700mm 732 700 Drain pipe Drain pump (O.D.:32) 41 57 178 (Duct) 100 33 23 40 122 2 Refrigerant piping Flare connection (liquid) 23 10 58 40 57 21 20 30 100 Air Filter Access door Q Make the access door at the appointed position properly for service maintenance. P Qx(R-1)=S H J K L M N P Q R S PEAD-RP35,50JA 1000 54 260 4 780 10 40.5 273 4 819 PEAD-RP60,71JA PEAD-RP100,125JA PEAD-RP140JA 1200 1500 1700 49 54 54 330 320 370 4 5 5 990 1280 1480 10 12 12 40 40 40 340 330 380 4 5 5 1020 1320 1520 Model 777 50 H Note2 Access door 50 250 ~30 45 0 0 450 0 30 han re t Mo Required space for service and maintenance 25 Unit : mm PEAD-RP35, 50, 60, 71, 100, 125, 140JAL 2xE-:2.9 Suspension bolt hole 4-14x30 Slot 210 G Air inlet C Air outlet A 18 B(Suspension bolt pitch) D (Duct) 100x(E-1)=F 15 21 Terminal block (Remote controller transmission line) 732 700 32 175±5mm (Actual length) 217 250 10 33 2×2-:2.9 1 Refrigerant piping Flare connection (gas) Control box 136 67 356 NOTE 1. Use M10 screw for the Suspension bolt (field supply). 2. Keep the service space for the maintenance at the bottom. 3. This chart indicates for PEAD-RP60•71•100•125•140JAL models,which have 2 fans. PEAD-RP35•50JAL models have 1 fan. 4. In case of the inlet duct is used,remove the air filter (supplied with the unit), then install the filter (field supply) at suction side. Drain pipe(O.D.:32) Model D E F G 954 1000 860 9 800 858 A PEAD-RP35,50JAL 900 PEAD-RP60,71JAL PEAD-RP100,125JAL PEAD-RP140JAL 6 B C 1100 1154 1200 1060 1400 1454 1500 1360 1600 1654 1700 1560 11 1000 1058 14 1300 1358 16 1500 1558 J Gas pipe Liquid pipe :12.7 :6.35 :15.88 :9.52 Kx(L-1)=M J K More than 20mm Ceiling surface 112 112 N-:2.9 More than 10mm Drain hose (I.D.:32) <accessory> Terminal block (Indoor/Outdoor connecting line) 11 23 40 122 100 178 (Duct) 643 (Suspension bolt pitch) 57 2 Refrigerant piping Flare connection (liquid) 23 10 58 40 57 20 30 100 Air Filter Access door Q Make the access door at the appointed position properly for service maintenance. P Qx(R-1)=S H J K L M N P Q R S PEAD-RP35,50JAL 1000 54 260 4 780 10 40.5 273 4 819 PEAD-RP60,71JAL PEAD-RP100,125JAL PEAD-RP140JAL 1200 1500 1700 49 54 54 330 320 370 4 5 5 990 1280 1480 10 12 12 40 40 40 340 330 380 4 5 5 1020 1320 1520 Model 777 50 H Note2 Access door 50 250 ~30 45 0 0 450 0 30 han re t Mo Required space for service and maintenance 26 A 39 Drain R1 565 Left side view Refrigerant pipe :9.52 (3/8 braze) Return air Return air sensor 50 Refrigerant pipe 10 :25.4 (1 braze) 634 530 A Rubber bush <Power supply wiring> Rubber bush <Outdoor unit connection wiring> Rubber bush <Remote controller wiring> 54 10 55 376 Supply air <Accessory> Pipe cover···················2pcs. (For dew condensation prevention of local piping and unit connection) Remote controller········1pc. 330 22 145 144 130 130 35 89 35 73 262 Control box 462 40 40 155 Supply air duct flange 45 20 42 Front view 1284 1400 1340 1260 1000 Top view 7x130(=910) 1300 130 22-: 3.1 20 34 31 Return air duct flange 105 40 4- :12 45 <For hanging bolt M10> [Field supply] 10 130 10 24-: 3 Holes 1102 8x130(=1040) 199 200 131 100 400 70 75 129 100 100 25 25 95 250 27 11 124 31 PEA-RP200GA Unit : mm A 39 50 10 A Left side view Drain R1 565 634 530 Return air sensor Rubber bush <Power supply wiring> Rubber bush <Outdoor unit connection wiring> 54 10 55 376 Supply air Control box 462 40 100 40 255 Supply air duct flange 45 20 42 124 66 Front view 1484 1600 1540 1460 1000 Top view 7x130(=910) 1500 400 130 130 20 34 66 10 Return air duct flange 205 40 4- :12 45 <For hanging bolt M10> [Field supply] 10 26- :3 Holes 22- :3.1 1302 9X130(=1170) 199 200 131 Rubber bush <Remote controller wiring> Refrigerant pipe :12.7 (1/2 braze) Return air Refrigerant pipe :25.4 (1 braze) 330 22 145 144 130 130 35 89 35 73 262 70 75 129 100 100 25 25 95 250 28 11 <Accessory> Pipe cover··················2pcs. (For dew condensation prevention of local piping and unit connection) Remote controller·······1pc. PEA-RP250GA Unit : mm 40 A *2 A 700 Return air sensor (2 places) 764 664 Left side view Refrigerant pipe 39 PEA-RP400GA : :9.52 (3/8 braze) PEA-RP500GA : :12.7 (1/2 braze) Drain R1 [2 places (*2 part)] Return air *2 *1 *1 50 10 50 10 Rubber bush <Remote controller wiring> Refrigerant pipe :25.4 (1 braze) [2 places (*1 part)] 120 Control box 100 149 29 Supply air 40 Supply air duct flange 20 45 395 42.5 Front view 1824 1947 1880 1800 1125 Top view 8X130(=1040) 1840 130 130 24-:3.1 36-:3 HOLES 10 280 42.5 10 1618 12X130(=1560) 40 4-:15 <For hanging bolt M12> [Field supply] 20 Return air duct flange 33 29 203 320 141 61 Rubber bush <Outdoor unit connection wiring> 60 60 60 570 425 59 595 Rubber bush <Power supply wiring> 525 22 22.5 81 4X120(=480) 117 156 117 22.5 102 40 130 130 40 188 340 29 22 <Accessory> Pipe cover··················4pcs. (For dew condensation prevention of local piping and unit connection) Remote controller·······1pc. PEA-RP400, 500GA Unit : mm 0 16 28.5 41 78.5 91 103.5 116 166 178.5 203.5 232.5 253.5 77-:5.1 Tapping screw hole 43 394 A 56 278.3 12.5 449 C Knockout hole for piping 372.3 356.3 327.5 43 Min.7 250mm or greater with optional drain pump installation. 291.5 265 56 4-:9 Bolt hole 6 46 60 70 46 56 238 213 43 B D Mount board Min.50 Knockout hole for left piping :65~:80 Knockout hole for lower piping 273.2 231.5 128.5 153.5 21.8 0 20 32.7 53.5 66 Indoor unit outline :65~:80 C 55 55mm or greater with left or rear left pipng or drain pump installation. Left side Min.250 Sleeve Through hole (purchased locally) Min.150 Center measurement hole :2.5 0 15 0 15 6 225 200 174 58 3.8 69 125 43 125 115 140 167 180.3 193.5 70 0 59 Min.50 550mm or greater with optional Min.220 drain pump installation. 281 197 295 8 Required space (Indoor unit) 200 225 238 265 291.5 327.5 356.3 372.3 30 449 688 898 192 612 B Mount board Terminal block for MA-remote controller (option) Emergency operation switch (cooling/heating) Receiver 5 A Terminal block for power supply (option) Terminal block for outdoor unit Knockout hole for right piping 249 Right side Drain hose :16 O.D Refrigerant pipe : :6.35 Liquid pipe Flared connection : 1/4F Refrigerant pipe : :12.7 Gas pipe Flared connection : 1/2F Size DEFROST/STAND BY lamp 169 158 184 155 Front side Top side Operation lamp Knockout hole for lower piping Under side 457 Gas pipe 539 Liquid pipe 610 Drain hose Front side (Grille open) 599 Louver (manual) Vane (auto) 387 PKA-RP35HAL PKA-RP50HAL Unit : mm Unit : mm PKA-RP60KAL PKA-RP71KAL PKA-RP100KAL Top side 431.7 11 140.3 65.2 423.7 Left side Right side Front side Mount board 365 Knockout hole for left piping C 74 A (855) 295 241 5 Operation lamp DEFROST/STAND BY lamp 1170 Receiver Knockout hole for right piping Front side (Grille open) Terminal block for outdoor unit Terminal block for power supply (option) Terminal block for MA-remote controller (option) Emergency operation switch (cooling/heating) 30 35 444 (Gas pipe) 66 123 154 482 (Liquid pipe) 585 (Drain hose) 134 Under side Piping connection department Refrigerant pipe : 9.52 Flared connection : 3/8F Gas pipe Refrigerant pipe : 15.88 Flared connection : 5/8F 16 Drain hose Sleeve Through hole (purchased locally) 75 Liquid pipe 75~ 80 O.D Louver (manual) Vane (auto) B B 54 0 Knockout hole for lower piping C B 3 364 384.5 408.5 439 454 465.5 314 10 0 10 60 110 Indoor unit outline 54 32 25 77 7.8 77 87 0 0 37.5 62.5 50 75 100 117 125 142 192 67 65 77 7.8 67 25 65 Mount board A 15.5 10.7 Center measurement hole Φ2.5 Temporarily fixing hole 314 75-Φ5.1 Tapping screw hole 454 439 408.5 384 364 Knockout hole for piping 517.4 4-Φ9 Bolt hole 60 110 65 104.5 129.5 167 217 242 279.5 292 264 292 308.5 311 Min. 220 550 mm or greater with optional drain pump installation Min. 50.5 108 mm or greater with left or rear left piping or drain pump installation 31 Wall hole for right rear piping 585 439 449.2 Knockout hole for rear piping (75×480) 339 349.2 384 0 189 339 384 439 430.5 585 Min. 48 Air outlet Min. 72.4 Wall hole for left rear piping Min. 250 Min. 7 265 mm or greater with optional drain pump installation Air inlet 530.5 7.5 R3 Required space (Indoor unit) 216.5 32 18 53 Filter hook 12.5 12.5 87.5 229.5 1 2 3 4 5 6 7 8 9 Ceiling 461 25 ø1 9 38 38 7 387 18 120° 85 260 2 8 48 233 246 When drain socket is installed (Drainage) 2 2 Drainage pipe connection(26mmI.D.) Drainage pipe connection(for the left arrangement) Knock out hole for left drain-piping arrangement Refrigerant-pipe connection(gas pipe side/flared connection) Refrigerant-pipe connection(liquid pipe side/flared connection) Knock out hole for upper drain pipe arrangement Knock out hole for fresh air intake ø100 Knock out hole for wiring arrangement 2-ø22 Knock out hole for wiring arrangement 2-ø26 Air intake Accessory···Drain socket (I.D. 26) Electrical box 138 86 4 Air outlet 878 853 960 917(Suspension bolt pitch) 182 140 62 80 1 In case of the rear pipe arrangement, make sure to remove the shaded portions from the independent piece. Then put the independent piece back in initial position. (The heat exchanger might be clogged because of dust) 75 3 When electrical box is pulled down 121 24 5 126 2 190 46 76 124 (71) 8 169 37 1 190 Electrical box 84 88 2 85 254 320 195 57 6 680 230 680 32 476 150 18 [FRONT VIEW] 5 10 51 184 (liquid ø6.35) (gas ø12.7) When drain socket is installed (Drainage) NOTES. 1.Use M10 or W3/8 screw for anchor bolt. 2.Please be sure when installing the drain pump (option parts), refrigerant pipe will be only upward. 246 233 203 PCA-RP50KA Unit : mm 121 37 190 46 1 2 3 4 5 6 7 8 9 461 25 ø1 9 38 7 387 18 120° 2 8 48 246 233 (Drainage) When drain socket is installed 138 85 86 260 2 4 2 Air outlet 1198 1173 1280 1237(Suspension bolt pitch) 182 140 62 80 1 Drainage pipe connection(26mmI.D.) Drainage pipe connection(for the left arrangement) Knock out hole for left drain-piping arrangement Refrigerant-pipe connection(gas pipe side/flared connection) Refrigerant-pipe connection(liquid pipe side/flared connection) Knock out hole for upper drain pipe arrangement Knock out hole for fresh air intake ø100 Knock out hole for wiring arrangement 2-ø22 Knock out hole for wiring arrangement 2-ø26 Air intake Accessory···Drain socket (I.D. 26) Flare nut ø6.35 (RP60 only) Electrical box Ceiling 38 24 5 In case of the rear pipe arrangement, make sure to remove the shaded portions from the independent piece. Then put the independent piece back in initial position. (The heat exchanger might be clogged because of dust) When electrical box is pulled down 75 169 3 124 76 (71) 2 8 126 1 190 Electrical box 84 88 2 85 254 320 195 57 680 230 680 33 476 150 [FRONT VIEW] 6 5 10 60 179 203 A B 246 233 71 180 200 (gas ø15.88) When drain socket is installed (Drainage) (liquid ) 236 4 GAS SIDE ø15.88 :Initial flare nut size ø9.52 5 LIQUID SIDE ø6.35 RP60 ø9.52 ø15.88 RP71 Use the current nuts meeting the pipe size of the outdoor unit. Available pipe size NOTES. 1.Use M10 or W3/8 screw for anchor bolt. 2.Please be sure when installing the drain pump (option parts), refrigerant pipe will be only upward. 51 A B PCA-RP60KA PCA-RP71KA Unit : mm 18 34 46 190 2 1 2 3 4 5 6 7 8 9 Electrical box 461 25 ø1 9 38 7 387 18 120° Electrical box 2 8 48 233 246 When drain socket is installed (Drainage) 138 260 85 86 In case of the rear pipe arrangement, make sure to remove the shaded portions from the independent piece. Then put the independent piece back in initial position. (The heat exchanger might be clogged because of dust) When electrical box is pulled down Ceiling 24 38 2 4 2 Drainage pipe connection(26mmI.D.) Drainage pipe connection(for the left arrangement) Knock out hole for left drain-piping arrangement Refrigerant-pipe connection(gas pipe side/flared connection) Refrigerant-pipe connection(liquid pipe side/flared connection) Knock out hole for upper drain pipe arrangement Knock out hole for fresh air intake ø100 Knock out hole for wiring arrangement 2-ø22 Knock out hole for wiring arrangement 2-ø26 Air intake Accessory···Drain socket (I.D. 26) 75 3 169 37 121 1 126 190 1 Air outlet 1518 1600 1493 1557 (Suspension bolt pitch) 182 140 62 80 2 320 76 124 71 5 85 254 8 6 680 [FRONT VIEW] 680 84 88 195 230 57 476 10 5 246 233 180 200 (liquid ø9.52) (gas ø15.88) When drain socket is installed (Drainage) 236 NOTES. 1.Use M10 or W3/8 screw for anchor bolt. 2.Please be sure when installing the drain pump (option parts), refrigerant pipe will be only upward. 51 PCA-RP100KA PCA-RP125KA PCA-RP140KA Unit : mm 150 18 1098 1136 986 <Air outlet> 75 <gas> <liquid> 21 110 <Air outlet> 80 70 Filter element for the exchange model:PAC-SG38KF-E (12pcs.) 360 handle 3 or more 100 <Flexible hose(accessory)> 650 289 <Suspension bolt pitch> 320 495 <Filter contour dimension> Filter (3-pieces) Inspection port (pipe sensor) 75 243 175 Suspension bolt 75 1224 <Suspension bolt pitch> <Air intake> NOTES. 1.Use M10 or W3/8 screw for anchor bolt. The half bottom of FAN CASING can be separated. 1180 102 110 258 43 197 <Air intake> 70~90 13 1 280 16 288 Electrical box 1 85 45 Rear wall 1136 Ceiling 176 105 140 18 Adjustable part 650 318 2 4 210 6 or more 366 100 38 120 165 90 Less than 254 295 7 Terminal block box :2 22 0 :20 9 130 250 Less than Allowing clearances 480 (122 ) 8 Refrigerant-pipe connection(gas pipe side/flared connection : 5/8 inch) Refrigerant-pipe connection(liquid pipe side/flared connection : 3/8 inch) Flexible hose(accessory) Drainage pipe connection(26mm I.D.) Knockout hole for behind refrigerant-piping arrangement Knockout hole for upper refrigerant-pipe arrangement Knockout hole for wiring arrangement : 2- : 27 Terminal block(indoor/outdoor connecting line) Terminal block(remote controller) Knockout hole (duct for fresh air intake): 2- : 200 · Optional parts:duct flange( : 200). model: PAC-SF28OF-E(1 pc.) 300 2 15 Less than 130 500 5 or more 90° 2~3 35 (Gap to ceiling) Terminal block box PCA-RP71HA Unit : mm Use the current nuts meeting the pipe size of the outdoor unit. NOTES. 1.Use M10 or W3/8 screw for anchor bolt. The half bottom of FAN CASING can be separated. <Air intake> 1482 1520 1370 <Air outlet> 75 <liquid> 21 80 70 360 Filter element for the exchange model:PAC-SG38KF-E (12pcs.) handle or more 100 <Flexible hose(accessory)> 650 289 <Suspension bolt pitch> 320 495 <Filter contour dimension> Filter (4-pieces) 243 <gas> Inspection port (pipe sensor) 75 43 197 Suspension bolt 1 18 45 85 140 2 4 Rear wall 298 176 105 Adjustable part 3 254 295 110 102 110 <Suspension bolt pitch> 75 1564 165 175 <Air outlet> <Air intake> 70~90 13 120 90 1608 1520 Ceiling 650 280 16 288 210 38 1 246 6 440 (122) 7 440 or more 100 9 250 :2 22 0 :20 Less than Allowing clearances Terminal block box 8 300 Electrical box Less than 130 Refrigerant-pipe connection(gas pipe side/flared connection : 5/8 inch) Refrigerant-pipe connection(liquid pipe side/flared connection : 3/8 inch) Flexible hose(accessory) Drainage pipe connection(26mm I.D.) Knockout hole for behind refrigerant-piping arrangement Knockout hole for upper refrigerant-pipe arrangement Knockout hole for wiring arrangement : 2- : 27 Terminal block(indoor/outdoor connecting line) Terminal block(remote controller) Knockout hole (duct for fresh air intake) : 2- : 200 · Optional parts:duct flange( : 200). model: PAC-SF28OF-E(1 pc.) Less than 2 15 500 130 (Gap to ceiling) 5 90° 2~3 Terminal block box or more 36 258 PCA-RP125HA Unit : mm 10 10 38 controller Front side Knockout hole for refrigerant and drainage 90 60 oval (Provided on both sides) 235 70 600 71 250 270 180 130 Metal fixture against overturning 530 520 260 240 370 340 125 132 15 111 Knockout hole for branch duct 100 130 130 38 20 10 827 30 130 50 260 Knockout hole for under-piping(120 70 oval) Terminal block for heater power supply 22 (Only PSH-P·GAH) Terminal block for indoor/outdoor connection. Knockout hole for bottom fixing 95 50 Knockout hole for wiring :27 (Provided on both sides) Front side Rear side A 105 Knockout hole for under-piping Drain pipe Gas pipe :15.88(5/8 inch) Liquid pipe :9.52(3/8 inch) Knockout hole for piping and wiring (140 80 oval) 47 95 Electrical parts box 277 461 20 20 160 218 VIEW "A" 100 240 115 40 1900 175 123 714 766 608 216 90 767 143 55 110 Rear side 590 37 480 40 186 66 Front 1,000 or more 100 or more 1 2 300 or more 5 or more 1. Service access allows for insertion of screw driver. 2. Adjustable 100 or more PSA-RP71GA Unit : mm controller 315 Knockout hole for refrigerant and drainage 90 60 oval (Provided on both sides) 70 600 71 330 350 260 130 Metal fixture against overturning 132 530 520 260 240 370 340 125 100 130 130 10 10 38 38 Front side 50 260 20 10 827 30 130 15 111 Knockout hole for branch duct Knockout hole for 95 under-piping(120 70 oval) Knockout hole for wiring :27 (Provided on both sides) A 20 461 Front side Rear side Knockout hole for under-piping 105 Gas pipe 40 Drain pipe :15.88(5/8 inch) Liquid pipe :9.52(3/8 inch) Knockout hole for piping and wiring (140 80 oval) 47 95 Electrical parts box 277 120 20 218 VIEW "A" Knockout hole for bottom fixing Terminal block for indoor/outdoor connection. Terminal block for heater power supply (Only PSH-P·GAH) 22 50 120 240 115 766 608 216 255 123 714 40 1900 140 767 201 77 110 261 66 Front 1,000 or more 100 or more 1. Service access allows for insertion of screw driver. 2. Adjustable 100 or more 1 2 300 or more 5 or more Rear side 590 38 480 PSA-RP100GA PSA-RP125GA PSA-RP140GA Unit : mm PUHZ-RP35VHA4 PUHZ-RP50VHA4 Unit : mm 400 :33 drain hole 347.5 330 300 Air intake :33 drain hole 365 155 152 43.6 Air intake 45.4 4-10 % 21 oval hole (M10 foundation bolt) 18 23 32.5 40 Service panel Service panel for charge plug Air discharge Handle for moving 150 43 183 69 287.5 Connection for gas pipe 90 10 155 300 35 600 Connection for liquid pipe Service port Installation bolt pitch: 500 800 1. FOUNDATION BOLTS Piping and wiring connection can be made from the rear direction only. 3. ATTACHING THE CONDUIT <Foundation bolt height> In order to attach the conduit, it is necessary to fix the metal plate with 2 screws to the back panel. Procure the metal plate and make screw holes locally. It is recommended to use the metal plate shown below. Align the metal plate to the marks on the unit and attach it. +1 18 or below 100 m Basically open Free space around the outdoor unit (basic example) 100 mm or more as long as no obstacle is placed on the rear and right-and-left sides of the unit. 2. PIPING-WIRING DIRECTION Please secure the unit firmly with 4 foundation (M10) bolts. (Bolts, washer and nut must be purchased locally.) ore or m mm 100 FOUNDATION mo rm ore +1 +2 ore or m mm 500 350 mm 40 + The position and the size of conduit hole depend on the conduit to be used. 20 or m ore 2 sides should be open in the right, left and rear side. + 1 In the place where short cycle tends to occur, cooling and heating capacity and power consumption might get lowered by 10%. Air outlet guide (optional PAC-SG58SG) will help them improve. + 2 If air discharges to the wall, the surface might get stained. Holes for metal plate fixing screw + The size of hole depends on the screw to be used. 39 80 Minimum installation space for outdoor unit 60 + Conduit hole over 100mm over 10mm Service space Over10 Front piping hole (Knockout) Front trunking hole (Knockout) 92 :92 40 65 45 Power supply wiring hole (2-:27Knockout) 19 92 55 Right piping hole (Knockout) 75 Piping Knockout Hole Details Air Intake 500 Over Handle for moving Refrigerant GAS pipe connction (FLARE):15.88(5/8 inch) Refrigerant LIQUID pipe connection (FLARE):9.52(3/8 inch) *1...Indication of STOP VALVE connection location. Example of Notes over 500mm FREE 2 SERVICE SPACE 40 :92 Over100 500 65 Right trunking hole (Knockout) 45 92 :92 40 Side Air Intake Handle for moving Handle for moving Rear Air Intake Rear piping hole (Knockout) Power supply wiring hole (2-:27Knockout) Rear trunking hole (Knockout) FOUNDATION <Foundation bolt height> Piping and wiring connections can be made from 4 directions: front, right, rear and below. Please secure the unit firmly with 4 foundation (M10) bolts. (Bolts and washers must be purchased locally.) Handle for moving Side Air Intake 4 PIPING-WIRING DIRECTIONS Power supply wiring hole (2-:27Knockout) Over 3 FOUNDATION BOLTS 943 Dimensions of space needed for service access are shown in the below diagram. 330 30 30 23 322 600 145 145 Earth terminal 950 Installation Feet Air Discharge 220 175 145 Rear Air Intake 41 Drain hole (5-:33) 71 2 1 Handle for moving Service panel Terminal Connections Left···Power supply wiring Reight···Indoor/Outdoor wiring 2-12 % 36 oval holes (Foundation Bolt M10) 57 175 2-U Shaped notched holes (Foundation Bolt M10) 19 370 28 Rear piping cover Front piping cover Bottom piping hole (Knockout) *1 431 over 10mm 55 27 673 The diagram below shows a basic example. Explantion of particular details is given in the installation manuals etc. 73 63 23 30 55 27 63 23 27 92 73 Less than 73 63 23 473 219 40 54 53 71 40 81 417 *1 447 1 FREE SPACE (Around the unit) PUHZ-RP60VHA4 PUHZ-RP71VHA4 Unit : mm FREE Over 150mm Over 10mm Over 10 Service space Handle for moving Front piping hole (Knock-Out) 92 ø92 60 Over 500 Rear Air Intake FOUNDATION <Foundation bolt height> Handle for moving Side Air Intake Piping and wiring connections can be made from 4 directions: FRONT,Right,Rear and Below. 4 PIPING-WIRING DIRECTIONS 75 55 29 92 ø92 75 92 Power supply wiring hole Power supply wiring hole (ø27Knock-Out) (ø40Knock-Out) Power supply wiring hole Power supply wiring hole Power supply wiring hole Power supply wiring hole (ø27Knock-Out) (ø27Knock-Out) (ø40Knock-Out) (ø40Knock-Out) Right piping hole Right trunking hole Rear trunking hole Front trunking hole 60 55 55 60 (Knock-Out) (Knock-Out) 75 50 (Knock-Out) (Knock-Out) Piping Knock-Out Hole Details Model A PUHZ-RP100~140VKA 1067 PUHZ-RP100~140YKA 919 3 FOUNDATION BOLTS Less than 30 Dimensions of space needed Please secure the unit firmly for service access are with 4 foundation (M10) bolts. shown in the below diagram. (Bolts and washers must be purchased locally.) 2 SERVICE SPACE 1 ···Refrigerant GAS pipe connection (FLARE)ø15.88(5/8F) 2 ···Refrigerant LIQUID pipe connection (FLARE)ø 9.52(3/8F) *1···Indication of STOP VALVE connection location. Example of Notes Over 1000mm Over 10mm 63 55 73 27 26 63 92 27 73 26 2 ø9 Rear piping hole (Knock-Out) Side Air Intake 330 1 FREE SPACE (Around the unit) Handle for moving 1338 Over 150 Over 500 60 632 369 45 110 160 362 225 160 160 1 Drain hole (5-ø33) 2 60 42 81 Handle for moving Service panel Bottom piping hole (Knock-Out) Front piping cover Rear piping cover Air intake Terminal connection Left···Power supply wiring Right···Indoor/Outdoor wiring 2-12×36 Oval holes (Foundation Bolt M10) 56 40 0 53 2-U Shaped notched holes (Foundation Bolt M10) 225 70 Earth terminal 1050 Air Discharge 600 Installation Feet Rear Air Intake 28 86 The diagram below shows a basic example. Explantion of particular details are given in the installation manuals etc. 63 26 73 55 27 60 A 30 26 154 19 370 417 *1 442 *1 450 41 136 PUHZ-RP100VKA PUHZ-RP125VKA PUHZ-RP140VKA PUHZ-RP100YKA PUHZ-RP125YKA PUHZ-RP140YKA Unit : mm Over 10mm Over 150mm Service space Over 10 Over 500 A 450 424 Front piping hole (Knock-Out) Front trunking hole (Knock-Out) Power supply wiring hole (ø40Knock-Out) 92 ø92 75 60 55 Handle for moving Over 150 29 55 92 75 50 ø92 Less than 30 Right trunking hole (Knock-Out) 75 92 55 60 Power supply wiring hole (ø27Knock-Out) Rear Air Intake FOUNDATION <Foundation bolt height> Power supply wiring hole (ø40Knock-Out) Over 500 Power supply wiring hole (ø27Knock-Out) Right piping hole (Knock-Out) Power supply wiring hole (ø27Knock-Out) Piping Knock-Out Hole Details ø9.52(3/8F) ø12.7(1/2F) 2 connection 60 Model PUHZ-RP200YKA PUHZ-RP250YKA 1 ···Refrigerant GAS pipe connection (attached JOINT)ø25.4(Brazing locally) 2 ···Refrigerant LIQUID pipe connection (FLARE) *1···Indication of STOP VALVE connection location. *2···(FLARE)ø 19.05(3/4F) Example of Notes Over 1000mm Over 10mm 60 3 FOUNDATION BOLTS 55 FREE 2 SERVICE SPACE 2 Rear piping hole (Knock-Out) ø9 Rear trunking hole (Knock-Out) Power supply wiring hole (ø40Knock-Out) Handle for moving Side Air Intake Piping and wiring connections can be made from 4 directions: FRONT,Right,Rear and Below. 4 PIPING-WIRING DIRECTIONS Handle for moving Side Air Intake 1338 Dimensions of space needed Please secure the unit firmly for service access are with 4 foundation (M10) bolts. shown in the below diagram. (Bolts and washers must be purchased locally.) 60 632 369 330 30 26 1 FREE SPACE (Around the unit) 63 55 73 27 26 63 92 27 26 73 73 63 26 27 154 Rear Air Intake 160 160 1050 Earth terminal Air Discharge 600 Installation Feet 110 160 362 225 45 136 2 42 Drain hole (5-ø33) 1 Handle for moving Service panel 81 Bottom piping hole (Knock-Out) Front piping cover Rear piping cover Air intake Terminal connection Left···Power supply wiring Right···Indoor/Outdoor wiring 2-12×36 Oval holes (Foundation Bolt M10) 60 Brazing 70 56 40 0 53 2-U Shaped notched holes (Foundation Bolt M10) 225 19 370 417 28 342 *1 A *1,*2 : 442 86 42 982 986 The diagram below shows a basic example. Explantion of particular details are given in the installation manuals etc. PUHZ-RP200YKA PUHZ-RP250YKA Unit : mm Unit : mm WIRELESS REMOTE CONTROLLER WIRED REMOTE CONTROLLER 58 19.5 159.3 120 130 19 55 43 4 WIRING DIAGRAM 4-1. INDOOR UNIT PLA-RP35BA PLA-RP50BA PLA-RP71BA2 PLA-RP100BA3 PLA-RP60BA PLA-RP125BA2 PLA-RP71BA PLA-RP140BA2 PLA-RP100BA PLA-RP125BA <Table 1> SW1 (MODEL SELECTION) [LEGEND] SYMBOL I.B CN2L CN32 CN41 CN51 FUSE LED1 LED2 LED3 SW1 SW2 SWE X1 DCL DP FS MF MV NAME INDOOR CONTROLLER BOARD CONNECTOR (LOSSNAY) CONNECTOR (REMOTE SWITCH) CONNECTOR (HA TERMINAL-A) CONNECTOR (CENTRALLY CONTROL) FUSE (T6.3AL250V) POWER SUPPLY (I.B) POWER SUPPLY (R.B) TRANSMISSION (INDOOR-OUTDOOR) SWITCH (MODEL SELECTION) +See table 1 SWITCH (CAPACITY CORD) +See table 2 CONNECTOR (EMERGENCY OPERATION) RELAY (DRAIN PUMP) REACTOR DRAIN-UP MACHINE DRAIN FLOAT SWITCH FAN MOTOR VANE MOTOR SYMBOL TB2 TB4 TB5,TB6 TH1 TH2 TH5 OPTION PART W.B BZ LED1 LED2 RU SW1 SW2 NAME TERMINAL BLOCK (Indoor unit Power (option)) TERMINAL BLOCK (INDOOR/OUTDOOR CONNECTING LINE) TERMINAL BLOCK (REMOTE CONTROLLER TRANSMISSION LINE) ROOM TEMP. THERMISTOR (0 / 15k, 25 / 5. 4k DETECT) PIPE TEMP. THERMISTOR/LIQUID (0 / 15k, 25 / 5. 4k DETECT) COND. / EVA. TEMP. THERMISTOR (0 / 15k, 25 / 5. 4k DETECT) SW1 SETTING MODELS PCB FOR WIRELESS REMOTE CONTROLLER BUZZER LED (OPERATION INDICATION : GREEN) LED (PREPARATION FOR HEATING : ORANGE) RECEIVING UNIT EMERGENCY OPERATION (HEAT / DOWN) EMERGENCY OPERATION (COOL / UP) PLA-RP·BA 1 2 3 4 5 PLA-RP71/125BA2 1 2 3 4 5 PLA-RP140BA2 PLA-RP100BA3 1 2 3 4 5 SETTING 1 2 3 4 5 1 2 3 4 5 50 1 2 3 4 5 60 1 2 3 4 5 VANE CNV(WHT) SW1 20 18 16 14 12 10 8 6 4 2 CN32 (WHT) 1 CN51(WHT) Pair No. 5 CN2L LED3 3 1 3 AUTO GRILLE CN3G 1 (BLK) MV MV ON OFF 125 140 1 2 3 4 5 1 2 3 4 5 ON OFF ON OFF ON OFF ON OFF DCL TRANSMISSION WIRES DC12V J41 J42 SW2 19 17 15 13 11 9 7 5 3 1 M ON OFF 100 YLW R.B I.B M ON OFF The black square (■) indicates a switch position. TB5 2 1 5 ON OFF 1 2 3 4 5 35 Refer to tables 1 and 2 5 ON OFF <Table 2> SW2 (CAPACITY CODE) SW2 CAPACITY SETTING CAPACITY 71 2 1 TB6 ON OFF WIRELESS CN90 (WHT) 9 5 M M MV MV GRILLE 1 4 4 CNB BZ SW1 LED2 SW2 LED1 2 1 INDOOR/OUTDOOR COMMUNICATION CN3C 1 CN41(WHT) 4 (BLU) 1 2 LED1 RU I-SEE SENSOR 1 6 RECTIFICATION (BLU) MT I-SEE SENSOR CORNER PANEL (OPTION PART) 1 4 4 1 2 t t TH2 TH5 t TH1 1 7 FAN CNMF (WHT) 4 MS 3 5 M 3 1 FUSE FS 1 CN3G X1 1 1 D.U.M 3 CNP (BLU) 5 3 1 TB4 YLW S1 ORN S2 S3 TO OUTDOOR UNIT ORN BRN M 3~ 1~ MF DP CN3A AUTOMATIC FILTER ELEVATION PANEL (OPTION PART) W.B Notes: 1.SymboIs used in wiring diagram above are, : Connector, : Terminal (block). 2.Indoor and outdoor connecting wires have poIarities, make sure to match terminal numbers (S1, S2, S3) for correct wirings. 3.Since the outdoor side electric wiring may change, be sure to check the outdoor unit electric wiring diagram for servicing. 4.This diagram shows the wiring of indoor and outdoor connecting wires.(specification of 230V), adopting superimposed system for power and signal. +1:If indoor and outdoor units have separate power supplies, refer to Fig 1. +2:For power supply system of this unit, refer to the caution label located near this diagram. YLW ORN + Be sure to turn off the source power and then disconnect fan motor connector. (Failure to do so will cause trouble in Fan motor) U.B 3 Please set the voltage using the remote controller. For the setting method,please refer to the indoor unit Installation Manual. DC280V REMOCON CN22 1 SWE (BLK) 1 3 ON OFF AUTO GRILLE I-SEE FLOAT SW LIQUID/PIPE INTAKE POWER I-SEE SENSOR SENSOR MOTOR CN4F CN44 CN20 CNAC CN4Y CN6Y (WHT) (WHT) (RED) (WHT) (WHT) (RED) 9 5 LED2 OUTDOOR 1 3 5 CN01 3 +1(Fig. 1) CN01 I.B (BLK) YLW 5 ORN 3 1 RED BLU GRN/YLW TB2 L N YLW TB4 ORN S1 ORN S2 BRN S3 I.B 1 3 INDOOR/OUTDOOR CN3C COMMUNICATION (BLU) 44 POWER SUPPLY ~(1PHASE) 230V 50Hz TO OUTDOOR UNIT 45 t° TH2 TH5 t° 1 2 3 4 CN44 TH1 SW2 SW1 SYMBOL I.B. CN2A CN2L CN32 CN41 CN51 CN90 CN105 LED1 LED2 LED3 (Red) 1 2 CN20 FS *1 1 2 3 4 CN4F CN41 OFF ON LED2 CNXB2 (Red) 1 CN2L 23 4 5 CN51 CN32 1 2 CNXC2 SWE LED1 4 3 2 1 CNXA2 (Blue) CN22 2 (Blue) 1 (Black) CN2A (Red) CN105 NAME SYMBOL NAME I.B. Indoor controller board Indoor controller board SW1 Switch (for mode selection) Connector (0-10V Analog input) SW2 Switch (for capacity code) Connector (Lossnay) SWE Connector (emergency operation) Connector (Remote switch) Connector (HA terminal-A) Power supply board P.B. F01 Connector (Centrally control) Fuse AC250V 6.3A ZNR01, 02 Varistor Connector (Wireless) DSA Arrester Connector (IT terminal) X01 Aux. relay LED(Power supply) X10 Aux. relay LED(Remote controller supply) LED(Transmission indoor-outdoor) SYMBOL EXPLANATION t° LED3 CN90 1 CN3C 3 (Blue) I.B. TB15 SYMBOL TH1 TH2 TH5 ACL FS TB4 M 1~ Drain pump CNP (Blue) X01 1 2 3 4 (Blue) X10 F01 CND 5 (Red) CNXC1 CNXA1 1 2 U ZNR01 3 Fan motor M 7 6 5 4 CNMF 1 DC280~340V Rectifier circuit <+A> TO CND TB4 1 2 TO CN3C ACL 1 2 1 2 S1 S2 S3 L N TO OUTDOOR UNIT POWER SUPPLY ~(1PHASE) 220~240V 50Hz (IN CASE OF CONNECT THE REPLACEMENT WIRING) TO OUTDOOR UNIT TO MA REMOTE CONTROLLER *1. Drain pump and float switch: only for PEAD-JA model +A S3 S1 S2 TB15 1 2 NOTE: 1. Since the outdoor side electric wiring may change be sure to NAME Intake air temp. Thermistor check the outdoor unit electric wiring for servicing. Pipe temp. Thermistor/liquid 2. Indoor and outdoor connecting wires are made with polarities, Cond./eva.temp. Thermistor make wiring matching terminal numbers (S1,S2,S3). AC reactor (Power factor improvement) Float switch 3. Symbols used in wiring diagram above are, terminal block, Terminal block connector. (Indoor/outdoor connecting line) Terminal block (Remote controller transmission line) *1 1 2 3 4 5 CNXB1 3 1 DSA ZNR02 U 1 2 P.B. 1 2 1 ACL INSIDE SECTION OF CONTROL BOX PEAD-RP35JA(L) PEAD-RP50JA(L) PEAD-RP60JA(L) PEAD-RP71JA(L) PEAD-RP100JA(L) PEAD-RP125JA(L) PEAD-RP140JA(L) POWER SUPPLY 3N~PE 380/400/415V 50Hz PE N 1 2 TB5 TB2 RED L1 WHITE L2 BLACK L3 RED 46 REMOTE CONTROLLER BOARD TB6 LCD REMOTE CONTROLLER CIRCUIT BREAKER (FIELD SUPPLY) PEA-RP200,250GA:15A BLACK INDOOR UNIT WHITE 2 1 CN3C 3 1 LED3 LED2 LED1 TAB1 CN2S CNSK 1 1 DC 3 2 13.1V 3 1 CN32 2 3 1 2 CN31 3 CN51 1 CND 3 2 1 3 2 1 C02 (3P) (Hi) CNDK 1 CN20 2 1 CN21 2 7 52F Lo 5 X1 3 FAN CR2 52F Hi 1 X4 X5 X6 X4 X5 X6 X1 5 4 C01 51F TB4 S1 S2 S3 49F CR1 X1 SWE ON OFF SW2 TH5 TH2 TH1 1 1 2 3 4 5 ON 2 CN41 OFF 3 INDOOR 4 CONTROLLER SW1 1 2 3 4 5 BOARD 1 ON CN29 OFF 2 MF1 3 1 C01 (6P) (Lo) FUSE 52F Hi ZNR 52F Lo 5 4 3 2 1 INDOOR POWER BOARD FB CN2D DC13.1V 1 2 3 4 5 CN90 6 7 8 9 1 CN22 2 1 CN2L 2 DSR DSA ZNR5~7 SNB BOARD 1 51F TERMINAL BLOCK NAME NAME FAN MOTOR (INDOOR) OVER CURRENT RELAY (INDOOR FAN MOTOR) MAGNETIC CONTACTOR (INDOOR FAN MOTOR<LOW SPEED>) MAGNETIC CONTACTOR (INDOOR FAN MOTOR<HIGH SPEED>) INTERNAL THERMOSTAT (INDOOR FAN MOTOR) TERMINAL BLOCK ROOM TEMP. THERMISTOR LIQUID PIPE TEMP. COND./EVA. TEMP. AUXILIARY RELAY SURGE KILLER FERRITE CORE FUSE (T6.3AL250V) VARISTOR AUXILIARY RELAY SWITCH (MODEL SELECTION) SWITCH (CAPACITY CODE) CONNECTOR (EMERGENCY OPERATION) LED (POWER SUPPLY) LED (POWER SUPPLY<REMOTE CONTROLLER>) LED (TRANSMISSION<INDOOR·OUTDOOR>) CONNECTOR (LOSSNAY) CONNECTOR (DRAIN SENSOR) CONNECTOR (REMOTE SWITCH) CONNECTOR (HA TERMINAL-A) CONNECTOR (CENTRALLY CONTROL) CONNECTOR (WIRELESS REMOTE CONTROLLER) VARISTOR ARRESTER TO OUTDOOR UNIT CONNECTING WIRES (POLAR) OUTDOOR UNIT Caution, 1. To protect fan motor from abnormal current, overcurrent relays are installed. Therefore, do not change factory set value of overcurrent relays. Note:1. The dotted lines show field wiring. 2. Color of earth wire is yellow and green twisting. 3. Specification subject to change without notice. 4. Indoor and outdoor connecting wires have polarities, make sure to match wiring and terminal. 5. Emergency operation If a trouble occurs with either the remote controller or the indoor microcomputer and no other trouble exists, emergency operation for cooling or heating can be performed by changing the setting of connector (SWE) "ON" on the indoor controller board. SWE :ON / Indoor fan is running at high speed. 6. mark is connector. mark is terminal. SYMBOL TB6 REMOTE CONTROLLER SYMBOL MF1 51F 52FLo 52FHi 49F TB2,4,5 TH1 TH2 TH5 X1 CR1,2 FB FUSE ZNR X4-6 SW1 SW2 SWE INDOOR LED1 CONTROLLER LED2 BOARD LED3 CN2L CN31 CN32 CN41 CN51 CN90 SNB ZNR5~7 BOARD 1 DSA,DSR INDOOR UNIT PEA-RP200, 250GA POWER SUPPLY 3N~PE 380/400/415V 50Hz 1 2 TB5 CR GREEN/YELLOW RED WHITE BLACK BLUE TB2 L1 L2 L3 N REMOTE CONTROLLER BOARD LCD TB6 REMOTE CONTROLLER PE CIRCUIT BREAKER (FIELD SUPPLY) PEA-RP400,500GA:15A FUSE FB12 3 2 1 C01 MF1 47 2 1 TAB1 CN2S CNSK 1 1 DC 3 2 13.1V (No.2) CND CNDK X1 5 3 1 CN3C 3 1 3 LED3 ZNR 1 CND SW2 TH1-2 TH2-2 TH5-2 FAN CNDK 7 X2 5 3 1 ON OFF ON OFF S1 S2 S3 TB4-1 S1 S2 S3 TB4-2 SWE ON OFF FAN X4 X5 X6 LED1 LED2 1 CN20 X4 X5 X6 2 3 1 7 ON OFF SWE ON OFF 1 1 2 3 4 5 2 CN41 3 INDOOR 4 CONTROLLER 1 2SW1 3 4 5 1 CN29 BOARD (No.2) 2 FB22 3 1 X4 X5 X6 1 CN20 X4 X5 X6 2 1 CN21 2 1 CN21 2 FUSE 1 SW2 3 2 ON OFF C02 1 1 1 2 3 4 5 2 CN41 3 INDOOR SW1 4 CONTROLLER 1 2 3 4 5 1 CN29 BOARD (No.1) 2 1 2 CN32 3 1 2 CN31 3 CN51 5 4 3 2 1 INDOOR FB21 POWER BOARD CN2D DC13.1V 1 2 3 4 5 CN90 6 7 8 9 1 CN22 2 TAB1 CN2S CNSK 1 DC 1 3 2 13.1V (No.1) 3 LED3 ZNR LED2 LED1 1 2 CN32 3 1 2 CN31 3 CN3C 3 1 FB11 INDOOR POWER BOARD CN2D DC13.1V 1 CN2L 2 2 1 1 2 3 4 5 CN90 6 7 8 9 1 CN22 2 CN51 5 4 3 2 1 TH5-1 TH2-1 1 CN2L 2 51F TH1-1 DSR DSA ZNR5~7 SNB BOARD 1 52F 49F 51F X01 X02 BLACK WHITE RED 5 52F C01 4 INDOOR UNIT TO OUTDOOR UNIT CONNECTING WIRES (POLAR) TERMINAL BLOCK NAME REMOTE CONTROLLER SYMBOL NAME TB6 TERMINAL BLOCK OUTDOOR UNIT SYMBOL TB3,TB8 FUSE (T6.3AL250V) VARISTOR AUXILIARY RELAY SWITCH (MODEL SELECTION) SWITCH (CAPACITY CORD) CONNECTOR (EMERGENCY OPERATION) LED (POWER SUPPLY) LED (POWER SUPPLY<REMOTE CONTROLLER>) LED (TRANSMISSION<INDOOR·OUTDOOR>) CONNECTOR (LOSSNAY) CONNECTOR (DRAIN SENSOR) CONNECTOR (REMOTE SWITCH) CONNECTOR (HA TERMINAL-A) CONNECTOR (CENTRALLY CONTROL) CONNECTOR (WIRELESS REMOTE CONTROLLER) VARISTOR ARRESTER NAME FAN MOTOR (INDOOR) OVER CURRENT RELAY (INDOOR FAN MOTOR) MAGNETIC CONTACTOR (INDOOR FAN MOTOR) INTERNAL THERMOSTAT (INDOOR FAN MOTOR) TERMINAL BLOCK ROOM TEMP. THERMISTOR LIQUID PIPE TEMP. COND./EVA. TEMP. AUXILIARY RELAY SURGE KILLER FERRITE CORE Caution, 1.To protect fan motor from abnormal current, overcurrent relays are installed. Therefore, do not change factory set value of overcurrent relays. Note:1. The dotted lines show field wiring. 2. Color of earth wire is yellow and green twisting. 3. Specification subject to change without notice. 4. Indoor and outdoor connecting wires have polarities, make sure to match wiring and terminal. 5. Emergency operation If a trouble occurs with either the remote controller or the indoor microcomputer and no other trouble exists, emergency operation for cooling or heating can be performed by changing the setting of connector (SWE) "ON" on the indoor controller board. SWE :ON / Indoor fan is running at high speed. 6. mark is connector. mark is terminal. OUTDOOR UNIT (No.2) (No.1) OUTDOOR UNIT TO OUTDOOR UNIT CONNECTING WIRES (POLAR) INDOOR UNIT SYMBOL MF1 51F 52F 49F TB2,4-1,4-2,5 TH1-1,1-2 TH2-1,2-2 TH5-1,5-2 X1,2 CR FB11,FB12 FB21,FB22 FUSE ZNR X4-6 SW1 SW2 SWE LED1 INDOOR CONTROLLER LED2 LED3 BOARD CN2L CN31 CN32 CN41 CN51 CN90 SNB ZNR5~7 BOARD 1 DSA,DSR PEA-RP400, 500GA PKA-RP35HAL PKA-RP50HAL [Explanation of symbols] Symbol I.B CN2L CN32 CN41 CN51 CN90 FUSE LED1 LED2 LED3 SW1 SW2 SWE X1 CNP Name Indoor controller board Connector (LOSSNAY) Connector ( Remote switch) Connector (HA terminal-A) Connector (Centrally control) Connector (Remote operation adapter) FUSE(T3.15AL250V) Power supply (I.B) Power supply (R.B) Transmission (Indoor-outdoor) Switch (Model selection) +See table 1 Switch (Capacity code) +See table 2 Connector (Emergency operation) Relay (Drain pump (option)) Drain pump (option) power supply (Drain pump (option)) CN4F R.B TB6 Drain float switch (Drain pump (option)) Wired remote controller(option) Terminal block (Remote controller transmission line) Symbol M MS S.W SWE2 TB2 TB4 TB5 TH1 Name Vane motor Fan motor Switch board Emergency operation Terminal block(Indoor unit Power (option)) Terminal block (Indoor/outdoor connecting line) Terminal block (Remote controller transmission line(option)) Room temp. Thermistor (0/15kΩ, 25/5.4kΩ Detect) TH2 Pipe temp. Thermistor/liquid (0/15kΩ, 25/5.4kΩ Detect) TH5 Cond./eva. temp. Thermistor (0/15kΩ, 25/5.4kΩ Detect) Pcb for wireless remote controller LED (Operation indication : Green) LED (Preparation for heating: Orange) Receiving unit REACTOR DRAIN PUMP (OPTION) DRAIN FLOAT SWITCH (OPTION) W.B LED1 LED2 REC1 DCL D P DP FS MS 3~ <Table 1> SW1 (MODEL SELECTION) DCL I.B CNMF 6 (WHT) FUSE 1 T11 SWE DB1 LED3 X1 LED2 1 Refer to tables 1and 2 1 2 CN2L (RED) 1 CN151 (WHT) 5 9 CN90 (WHT) 1 CN20 (RED) 1 2 CN41 (WHT) 1 CN44 (WHT) 4 4 YLW 1 CN32 3 (WHT) BLK 1 1 5 CN51 (WHT) CN4F (WHT) CNRU (WHT) TB4 YLW S1 ORN S2 S3 SETTING 1 2 3 4 5 TO OUTDOOR UNIT MODELS M 1~ ORN BRN 2 LDSWE(B) SWE2 1 2 3 4 5 RP50 RU LD101(B) REC1 SETTING 1 2 3 4 5 RP35 S.W W.B 6 ON OFF <Table 2> SW2 (CAPACITY CODE) DP 3 1 CNP(BLU) CN3C 3 (BLU) 1 LDSWE(A) (BLU) YLW ORN CN01 (BLK) LED1 ON OFF 1 3 5 ON OFF ON OFF The black square (■) indicates a switch position. R.B BLU 4 CN22 1 (BLU) 2 LED1 BLU LED2 1 2 TB6 1 2 TB5 (OPTION PARTS) M t ○ t ○ TH1 t TH2 TH5 ○ When attaching When attaching drain drain pump(option), pump (option) remove the jumper 1 4 connector CN4F FLOAT SW CN4F and fit the drain (WHT) FS float switch (FS). +1(Fig. 1) CN01 I.B (BLK) 1 3 5 YLW ORN Notes: 1. SymboIs used in wiring diagram above are, : Connector, : Terminal (block). I.B 2. Indoor and outdoor connecting wires have poIarities, make sure to match terminal numbers (S1, S2, S3) for correct wirings. 1 3 3. Since the outdoor side electric wiring may change, be sure to check the outdoor unit CN3C(BLU) electric wiring diagram for servicing. 4. This diagram shows the wiring of indoor and outdoor connecting wires. (specification of 230V), adopting superimposed system for power and signal. +1: If indoor and outdoor units have separate power supplies, refer to Fig. 1. +2: For power supply system of this unit, refer to the caution label located near this diagram. 48 RED BLU GRN/YLW YLW ORN ORN BRN TB2 L N POWER SUPPLY ~(1PHASE) 230V 50Hz TB4 S1 S2 S3 INDOOR/OUTDOOR COMMUNICATION TO OUTDOOR UNIT PKA-RP60KAL PKA-RP71KAL PKA-RP100KAL [LEGEND] SYMBOL I.B CN2L CN32 CN41 CN51 CN90 FUSE LED1 LED2 LED3 SW1 SW2 SWE X1 CNP CN4F R.B TB6 NAME Indoor controller board Connector (LOSSNAY) Connector (Remote switch) Connector (HA terminal-A) Connector (Centrally control) Connector (Remote operation adapter) FUSE (T3.15AL250V) Power supply (I.B) Power supply (R.B) Transmission (Indoor-outdoor) Switch (Model selection) +See table 1 Switch (Capacity code) +See table 2 Connector (Emergency operation) Relay (Drain pump(option)) Drain pump (option) power supply (Sold separately:Drain pump(option)) Drain float switch (Sold separately:Drain pump (option)) Wired remote controller Terminal block (Remote controller transmission line) SYMBOL M MS S.W SWE2 TB2 TB4 TB5 TH1 TH2 TH5 W.B LED1 LED2 REC1 DCL DP FS NAME Vane motor Fan motor Switch board Emergency operation Terminal block (Indoor unit Power (option)) Terminal block (Indoor/outdoor connecting line) Terminal block (Remote controller transmission line) Room temp. Thermistor (0 / 15k, 25 / 5. 4k Detect) Pipe temp. Thermistor/liquid (0 / 15k, 25 / 5. 4k Detect) Cond. / eva. temp. Thermistor (0 / 15k, 25 / 5. 4k Detect) Pcb for wireless remote controller LED (Operation indication : Green) LED (Preparation for heating : Orange) Receiving unit REACTOR DRAIN PUMP (OPTION) DRAIN FLOAT SWITCH (OPTION) MF +1(Fig. 1) CN01 I.B (BLK) YLW 1 ORN 3 5 INDOOR/OUTDOOR COMMUNICATION The black square (■) indicates a switch position. Notes: 1. SymboIs used in wiring diagram above are, :Connector, : Terminal (block). 2. Indoor and outdoor connecting wires have poIarities, make sure to match terminal numbers (S1, S2, S3) for correct wirings. 3. Since the outdoor side electric wiring may change, be sure to check the outdoor unit electric wiring diagram for servicing. 4. This diagram shows the wiring of indoor and outdoor connecting wires.(specification of 230V), adopting superimposed system for power and signal. +1 If indoor and outdoor units have separate power supplies, refer to Fig 1. +2 For power supply system of this unit, refer to the caution label located near this diagram. 49 TB2 L N YLW TB4 ORN S1 ORN S2 BRN S3 I.B 1 3 CN3C (BLU) RED BLU GRN/YLW POWER SUPPLY ~(1PHASE) 230V 50Hz TO OUTDOOR UNIT PCA-RP50KA PCA-RP60KA PCA-RP100KA PCA-RP125KA PCA-RP71KA PCA-RP140KA [ LEGEND] SYMBOL I.B CN2L CN32 CN41 CN51 FUSE LED1 LED2 LED3 SW1 SW2 SWE X1 R.B DCL MF MV TB2 NAME INDOOR CONTROLLER BOARD CONNECTOR (LOSSNAY) CONNECTOR (REMOTE SWITCH) CONNECTOR (HA TERMINAL-A) CONNECTOR (CENTRALLY CONTROL) FUSE (T6.3AL250V) POWER SUPPLY (I.B) POWER SUPPLY (R.B) TRANSMISSION (INDOOR-OUTDOOR) SWITCH (MODEL SELECTION) + See table 1 SWITCH (CAPACITY CODE) + See table 2 CONNECTOR (EMERGENCY OPERATION) RELAY (DRAIN PUMP) WIRED REMOTE CONTROLLER BOARD REACTOR FAN MOTOR VANE MOTOR TERMINAL BLOCK (Indoor unit Power (optional parts)) SYMBOL TB4 TB5,TB6 NAME TERMINAL BLOCK (INDOOR/OUTDOOR CONNECTING LINE) TERMINAL BLOCK (REMOTE CONTROLLER TRANSMISSION LINE) ROOM TEMP. THERMISTOR (0°C / 15kΩ, 25°C / 5. 4kΩ DETECT) PIPE TEMP. THERMISTOR/LIQUID (0°C / 15kΩ, 25°C / 5. 4kΩ DETECT) COND. / EVA. TEMP. THERMISTOR (0°C / 15kΩ, 25°C / 5. 4kΩ DETECT) TH1 TH2 TH5 OPTIONAL PARTS W.B BZ LED1 LED2 RU SW1 SW2 DP FS PCB FOR WIRELESS REMOTE CONTROLLER BUZZER LED (OPERATION INDICATION : GREEN) LED (PREPARATION FOR HEATING : ORANGE) RECEIVING UNIT EMERGENCY OPERATION (HEAT / DOWN) EMERGENCY OPERATION (COOL / UP) DRAIN LIFT UP MECHANISM DRAIN FLOAT SWITCH Refer to tables 1 and 2 DCL TB5 2 1 TRANSMISSION WIRES DC12V 2 1 TB6 YLW R.B I.B VANE CNV (WHT) SW1 20 18 16 14 12 10 8 6 4 2 J41 J42 SW2 19 17 15 13 11 9 7 5 3 1 Pair No. CN32 (WHT) 1 CN51 (WHT) 5 CN2L LED3 LED2 1 4 1 2 INDOOR/OUTDOOR COMMUNICATION CN3C (BLU) REMOCON CN22 (BLU) 1 SWE OUTDOOR 1 3 5 CN01 (BLK) 1 3 CN41 (WHT) 2 1 LED1 3 DC311~339V RECTIFICATION ON OFF WIRELESS CN90 (WHT) 1 FLOAT SW CN4F (WHT) 9 1 LIQUID/PIPE INTAKE CN44 CN20 (WHT) (RED) 4 1 2 t° t° TH2 TH5 t° TH1 1 4 FUSE 7 FAN CNMF (WHT) 4 MS 9 CNB 5 M MV BZ SW1 LED2 SW2 LED1 When attaching drain pump (optional parts), remove the jumper connector CN4F and fit the drain float switch (FS). RU W.B (OPTIONAL PARTS) When attaching drain pump (optional parts) FLOAT SW CN4F (WHT) 1 4 FS 3~ CN01 (BLK) 5 3 1 I.B YLW YLW ORN TB2 RED L BLU N GRN/YLW YLW TB4 ORN S1 ORN S2 BRN S3 I.B 1 3 INDOOR/OUTDOOR CN3C COMMUNICATION (BLU) 1 2 3 4 5 POWER SUPPLY ~(1PHASE) 230V 50Hz 1 D.U.M 3 CNP (BLU) TO OUTDOOR UNIT ORN BRN M 1~ +Be sure to turn off the source power and then disconnect fan motor connector. (Failure to do so will cause trouble in Fan motor) SW1 Service DCL 1 TB4 YLW S1 ORN S2 S3 DP MF (OPTIONAL PARTS) <Table 1> SW1 (MODEL SELECTION) + 1 (Fig. 1) YLW ORN X1 <Table 2> SW2 (CAPACITY CODE) SW2 MODELS Service MODELS PCA-RP50KA ON OFF PCA-RP60KA PCA-RP71KA 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 ON PCA-RP100KA OFF ON PCA-RP125KA OFF ON PCA-RP140KA OFF Service 1 2 3 4 5 1 2 3 4 5 1 2 3 4 5 ON OFF ON OFF ON OFF The black square (■) indicates a switch position. TO OUTDOOR UNIT Notes: 1. SymboIs used in wiring diagram above are, :Connector, :Terminal (block). 2. Indoor and outdoor connecting wires are made with poIarities, make wiring matching terminal numbers (S1, S2, S3). 3. Since the outdoor side electric wiring may change, be sure to check the outdoor unit electric wiring for servicing. 4. This diagram shows the wiring of indoor and outdoor connecting wires (specification of 230V), adopting superimposed system for power and signal. + 1: If indoor and outdoor units have separate power supplies, refer to Fig. 1. + 2: For power supply system of this unit, refer to the caution label located near this diagram. 50 PCA-RP71HA [LEGEND] SYMBOL P. B I. B FUSE CN2L CN32 CN41 CN51 LED1 LED2 LED3 X1 X4 X5 X6 SW1 SW2 PCA-RP125HA NAME INDOOR POWER BOARD INDOOR CONTROLLER BOARD FUSE (T6.3AL250V) CONNECTOR (LOSSNAY) CONNECTOR (REMOTE SWITCH) CONNECTOR (HA TERMINAL-A) CONNECTOR (CENTRALLY CONTROLL) POWER SUPPLY (I. B) POWER SUPPLY (R. B) TRANSMISSION(INDOOR-OUTDOOR) RELAY (DEW PREVENTION HEATER) RELAY(FAN MOTOR) RELAY(FAN MOTOR) RELAY(FAN MOTOR) SWITCH (MODEL SELECTION) See Table 1. SWITCH (CAPACITY CODE) See Table 2. SYMBOL MF1, MF2 C1, C2 H2 TB2 NAME FAN MOTOR CAPACITOR(FAN MOTOR) DEW PREVENTION HEATER TERMINAL BLOCK(INDOOR UNIT POWER (OPTION)) TB4 TERMINAL BLOCK(INDOOR/OUTDOOR TB5,TB6 CONNECTING LINE) TERMINAL BLOCK(REMOTE CONTROLLER TRANSMISSION LINE) ROOM TEMP.THERMISTOR (0°C/15k, 25°C/5.4k DETECT) TH1 TH2 PIPE TEMP.THERMISTOR/LIQUID (0°C/15k, 25°C/5.4k DETECT) TH5 COND./ EVA.TEMP.THERMISTOR (0°C/15k, 25°C/5.4k DETECT) R. B WIRED REMOTE CONTROLLER BOARD SWITCH (EMERGENCY OPERATION) SWE For PCA-RP125HA 1 1 I.B FAN 1 3 5 7 (WHT) CN2S (WHT) 1 2 DC13.1V S1 S2 S3 FUSE CN41 TH1 PIPE REMOCON CN29 CN22 (BLK) (BLU) 1 2 1 3 TH2 TH5 1 2 BLU BLU 1 2 BLK BLK YLW ORN ORN I.B YLW ORN LED3 LED2 LED1 INTAKE LIQUID CN20 CN21 (RED) (WHT) 1 2 1 2 WHT WHT SW1 Refer to tables 1 and 2 for service PCB. ON OFF RED BLU GRN/YLW CN51 CN32 ON OFF Table 1 SW1 Service board 1 2 3 4 5 +1 (Fig.1) CN2L X6 X5 X4 SW2 TO OUTDOOR UNIT D.HEATER 1 3 ROWER 1 3 ROWER 1 3 1 2 1 3 CNC CNDK CND ROWER INDOOR/OUTDOOR COMMUNICATION (RED) (RED) (ORN) CN2D(WHT) CN3C(BLU) X6 X5 X4 SWE Please set the voltage using the remote controller. For the setting method, please refer to the indoor unit Installation Manual. TB4 YLW ORN ORN BRN BLK WHT H2 1 2 3 YLW ORN BRN C2 GRY (RED) YLW YLW ORN C1 RED P.B CNDK RED WHT 6 5 4 3 2 1 BLK BLU YLW WHT 6 5 4 3 2 1 BLK BLU YLW WHT ORN RED BLK BLU YLW WHT MF2 ORN RED BLK BLU YLW WHT MF1 1 3 BRN TB2 L N POWER SUPPLY ~(1PHASE) 230V 50Hz TB4 S1 S2 S3 1 3 POWER INDOOR/OUTDOOR CND COMMUNICATION (ORN) CN3C (BLU) TB5 2 TRANSMISSION WIRES DC12V 1 R.B 1 TB6 2 Table 2 MODELS PCA-RP71HA SW2 MODELS Service board Service board 1 2 3 4 5 1 2 3 4 5 ON PCA-RP125HA ON OFF OFF The black square (■) indicates a switch position. Notes: 1. SymboIs used in wiring diagram above are, : Connector, : Terminal (block). 2. Indoor and outdoor connecting wires have poIarities, make sure to match terminal numbers (S1, S2, S3) for correct wirings. 3. Since the outdoor side electric wiring may change, be sure to check the outdoor unit electric wiring diagram for servicing. 4. This diagram shows the wiring of indoor and outdoor connecting wires (specification of 230V), adopting superimposed system for power and signal. +1: When supplying power separately to indoor and outdoor units, refer to Fig 1. +2: For power supply system of this unit, refer to the caution label located near this diagram. 51 TO OUTDOOR UNIT PSA-RP71GA [LEGEND] SYMBOL P.B I.B FUSE CN2L CN32 CN41 CN51 LED1 LED2 LED3 PSA-RP100GA PSA-RP125GA NAME SYMBOL I.B SW1 INDOOR POWER BOARD SW2 INDOOR CONTROLLER BOARD FUSE (T6.3AL250V) SWE CONNECTOR (LOSSNAY) X2 CONNECTOR (REMOTE SWITCH) X4 X5 CONNECTOR (HA TERMINAL-A) X6 CONNECTOR (CENTRALLY CONTROL) R.B POWER SUPPLY (I.B) POWER SUPPLY (R.B) TB6 TRANSMISSION (INDOOR-OUTDOOR) HEATER FS1,2 H 26H 88H PSA-RP140GA NAME SWITCH (MODEL SELECTION) See Table 1. SWITCH (CAPACITY CODE) See Table 2. SWITCH (EMERGENCY OPERATION) RELAY (LOUVER) RELAY (FAN MOTOR) RELAY (FAN MOTOR) RELAY (FAN MOTOR) WIRED REMOTE CONTROLLER BOARD SYMBOL C MF ML NAME CAPACITOR (FAN MOTOR) FAN MOTOR LOUVER MOTOR TB2 TERMINAL BLOCK (HEATER) PSH-P·GAH models only or option for PSA-RP·GA models. TB4 TERMINAL BLOCK (INDOOR/OUTDOOR CONNECTING LINE) TH1 TERMINAL BLOCK (REMOTE CONTROLLER TRANSMISSION LINE) TH2 THERMAL FUSE (110°C16A) HEATER HEATER THERMAL SWITCH HEATER CONTACTOR ROOM TEMP.THERMISTOR (0°C/15k, 25°C/5.4k DETECT) PIPE TEMP.THERMISTOR/LIQUID (0°C/15k, 25°C/5.4k DETECT) TH5 COND./EVA.TEMP.THERMISTOR (0°C/15k, 25°C/5.4k DETECT) INDOOR UNIT TB4 YLW S1 P.B CNSK (RED) CN2S (WHT) 2 1 3 2 1 DC13.1V S2 S3 Please set the voltage using the remote controller. For the setting method, please refer to the indoor unit Installation Manual. TO OUTDOOR UNIT 1 (Fig.1) ORN MF ORN RED BLU GRY/YLW ML C X6 X5 X4 2 1 2 1 2 1 X2 X6 X5 X4 LED3 LED2 LED1 SW2 SWE ON SW1 OFF CN24 TH2 Refer to tables 1 and 2 for service PCB. R.B 2 1 I.B YLW YLW 1 LIQUID WIRELESS CN21 CN90 (WHT) (WHT) INTAKE CN20 REMOCON 2 (RED) CN22 (BLU) 1 PIPE CN29 (BLK) CN2L CN41 CN32 2 TB6 TH5 HEATER CN24 (YLW) 88H 6YLW FS2 6 5 RED 26H RED SW2 Service board 1 2 3 4 5 PSA-RP.GA ON PSH-P.GAH OFF MODELS Table 2 SW2 Service board PSA-RP71GA 1 2 3 4 5 ON PSH-P71GAH OFF MODELS 1 2 3 4 5 PSA-RP125GA PSH-P125GAH 1 2 3 4 5 PSA-RP140GA PSH-P140GAH 1 2 3 4 5 FS1 RED WHT H Table 1 PSA-RP100GA PSH-P100GAH BLU 1 TH1 PSH -P.GAH models only 1 3 INDOOR/OUTDOOR COMMUNICATION CN3C (BLU) 1 2 RED BLU L N TB4 S1 S2 S3 I.B BRN ORN CN51 X2 1 2 POWER CN2D (WHT) YLW ORN POWER 1 3 CND (ORN) BRN ORN POWER 1 3 CNDK (RED) BLK WHT RED WHT LOUVER 1 3 CNL (YLW) YLW ORN YLW YLW FAN 1 3 5 7 (WHT) I.B FUSE BLK BLU YLW WHT RED TB2 1 3 1 3 POWER SUPPLY ~(1PHASE) 230V 50Hz TO OUTDOOR UNIT POWER INDOOR/OUTDOOR CND COMMUNICATION (ORN) CN3C (BLU) BLU TRANSMISSION WIRES DC12V RED 5 88H TB2 3 RED L BLU N GRN/YLW POWER SUPPLY ~(1 PHASE) 230V 50Hz Notes: 1. SymboIs used in wiring diagram above are, : Connector, : Terminal (block). 2. Indoor and outdoor connecting wires have poIarities, make sure to match terminal numbers (S1, S2, S3) for correct wirings. 3. Since the outdoor side electric wiring may change, be sure to check the outdoor unit electric wiring diagram for servicing. 4. This diagram shows the wiring of indoor and outdoor connecting wires (specification of 230V), adopting superimposed system for power and signal. +1: When supplying power separately to indoor and outdoor units, refer to Fig 1. +2: For power supply system of this unit, refer to the caution label located near this diagram. ON OFF ON OFF ON OFF The black square (■) indicates a switch position. 52 4-2. OUTDOOR UNIT PUHZ-RP35VHA4 PUHZ-RP50VHA4 SYMBOL TB1 MC MF1 21S4 63H TH3, TH33 TH4 TH6 TH7 TH8 TH32 LEV-A, LEV-B ACL CY1,CY2 P.B. TABR/S TABU/V/W NAME Terminal Block<Power Supply, Indoor/Outdoor> Motor for Compressor Fan Motor Solenoid Valve (Four-Way Valve) High Pressure Switch Thermistor<Outdoor Pipe> Thermistor<Discharge> Thermistor<Outdoor 2-Phase Pipe> Thermistor<Outdoor> Thermistor<Heat Sink> Thermistor<Shell> Electronic Expansion Valve Reactor Reactor Power Circuit Board Connection Terminal<L/N-Phase> Connection Terminal<U/V/W-Phase> SYMBOL IPM PFC CB1~CB3 N.F. LI/LO NI/NO EI,E2,E3 52C C.B. SW1 NAME Power Module Converter Main Smoothing Capacitor Noise Filter Circuit Board Connection Terminal<L-Phase> Connection Terminal<N-Phase> Connection Terminal<Ground> 52C Relay Controller Circuit Board Switch<Forced Defrost, Defect History Record Reset, Refrigerant Address> Switch<Test Operation> Switch<Function Switch> Switch<Model Select> Switch<Function Setup> Switch<Function Setup> Switch SW4 SW5 SW6 SW7 SW8 SW9 SYMBOL LED1,LED2 NAME LED <Operation Inspection Indicators> Fuse<T6.3AL250V> Switch<Pump Down> Connector<Emergency Operation> Connector<Connection for Option> Connector<Connection for Option> Connector<A-Control Service Inspection Kit> Connector <Connected to Optional M-NET Adapter Board> Connector <Connected to Optional M-NET Adapter Board> Connector < Connected for Option (Contact Input)> Relay F1~4 SWP CN31 CN51 SS CNM CNMNT CNVMNT CNDM X51,X52 When M-NET adapter is connected LEV-B M M 5 C. B. t° 1 2 1 TH7/6 TH3 TH4 (RED) (WHT) (WHT) LEV-A (WHT) 6 1 6 1 CN2 (WHT) 3 1 TRANS 3 1 LEV-B CNVMNT CNMNT (RED) (WHT) (WHT) 1 3 7 14 CNM (WHT) 1 2 2 F1 3 1 X52 2 21S4 3 (GRN) F4 4 M-NET ADAPTER 2 1 CND (WHT) 3 1 3 A B S 1 TB7 5 M-NET 1 X51 5 F3 CNAC (WHT) 1 LED4 3 1 2 2 SW12 LED3 CN31 CN52C (RED) CN4 (WHT) CNDC 1 (PNK) F2 5 CNDM (WHT) 12 CN51 (WHT) TH33 TH32 (YLW) (BLK) 4 SW5 1 SW6 12 SW1 3 *1 SW4 SWP SW8 1 1 3 LED2 *1 63H (YLW) CNS (WHT) 5 t° LED1 CNF1 7 (WHT) 1 t° t° LED2 MF1 MS 3~ t° SW1 1 SW9 SW7 t° 5 3 SW11 CN5 (WHT) TH33 TH32 TH7 TH6 TH3 TH4 LEV-A LED5 CN2M (WHT) LED1 63H 1 3 1 SS (WHT) 21S4 RED RED RED WHT WHT WHT N. F. ACL MC MS 3~ NO PFC 2 CN4 1 (WHT) 2 2 2 CN52C (BLK) CN5 1 (RED) 2 2 1 52C U RED BLK P. B. WHT W V LO IPM TABV TABW RED WHT TABS E3 1 TH8 CN3 1 (WHT) 2 3 t° CNAC2 (RED) TABR BLK 5 1 CN5 (RED) TABU CN2 (WHT) CB1 CB2 CB3 1 7 2 2 E2 BLK 1 CNAC1 (WHT) 3 *1MODEL SELECT L N CY1 CY2 S1 S2 EI NI LI BRN YLW 1 2 3 4 5 6 *2. SW5 -1 to 5 : Function Switch The black square (■) indicates a switch position. U BLK 1 2 3 4 5 6 7 8 ON OFF ORN ON OFF U 1 2 3 4 5 6 GRN/YLW 50V 1 2 3 4 5 6 7 8 SW5-6 *2 ON OFF BLU 35V SW6 ON OFF RED MODEL S3 TB1 M-NET ADAPTER INDOOR UNIT POWER SUPPLY ~/N 230V 50Hz 53 SYMBOL TB7 CN5 CND CN2M SW1 SW11 NAME Terminal Block<M-net connection> Connector<Transmission> Connector<Power Supply> Connector<M-NET communication> Switch<Status of communication> Switch<Address setting : 1s digit> SYMBOL SW12 LED1 LED2 LED3 LED4 LED5 NAME Switch<Address setting : 10s digit> LED<Power Supply : DC5V> LED<Connection to Outdoor Unit> LED<Transmission : Sending> LED<Transmission : Recelving> LED<Power Supply : DC12V> PUHZ-RP60VHA4 PUHZ-RP71VHA4 SYMBOL TB1 MC MF1 21S4 63H TH3, TH33 TH4 TH6 TH7 TH8 TH32 LEV-A, LEV-B ACL CY1,CY2 P.B. TABR/S TABU/V/W IPM NAME Terminal Block<Power Supply, Indoor/Outdoor> Motor for Compressor Fan Motor Solenoid Valve (Four-Way Valve) High Pressure Switch Thermistor<Outdoor Pipe> Thermistor<Discharge> Thermistor<Outdoor 2-Phase Pipe> Thermistor<Outdoor> Thermistor<Heat Sink> Thermistor<Shell> Electronic Expansion Valve Reactor Reactor Power Circuit Board Connection Terminal<L/N-Phase> Connection Terminal<U/V/W-Phase> Power Module SYMBOL PFC CB1~CB3 N.F. LI/LO NI/NO EI,E2,E3 52C C.B. SW1 NAME Converter Main Smoothing Capacitor Noise Filter Circuit Board Connection Terminal<L-Phase> Connection Terminal<N-Phase> Connection Terminal<Ground> 52C Relay Controller Circuit Board Switch<Forced Defrost, Defect History Record Reset, Refrigerant Address> Switch<Test Operation> Switch<Function Switch> Switch<Model Select> Switch<Function Setup> Switch<Function Setup> Switch LED <Operation Inspection Indicators> SW4 SW5 SW6 SW7 SW8 SW9 LED1,LED2 SYMBOL F1~4 SWP CN31 CN51 SS CNM CNMNT NAME Fuse<T6.3AL250V> Switch<Pump Down> Connector<Emergency Operation> Connector<Connection for Option> Connector<Connection for Option> Connector<A-Control Service Inspection Kit> Connector <Connected to Optional M-NET Adapter Board> Connector <Connected to Optional M-NET Adapter Board> Connector < Connected for Option (Contact Input)> Relay CNVMNT CNDM X51,X52 When M-NET adapter is connected TH33 TH32 TH7 TH6 TH3 TH4 LEV-A LEV-B M M 5 t° 1 2 1 LEV-A (WHT) 6 1 6 1 1 3 1 TRANS 7 14 F1 3 1 2 21S4 3 (GRN) F4 4 3 A B S 1 TB7 5 M-NET 1 X51 X52 2 CND (WHT) 3 1 3 1 2 5 F3 CNAC (WHT) 1 M-NET ADAPTER 2 1 CN31 1 2 2 F2 5 CN52C (RED) CN4 (WHT) CNDC 1 (PNK) 3 1 CNM (WHT) 63H (YLW) CN2 (WHT) 3 3 LEV-B CNVMNT CNMNT (RED) (WHT) (WHT) SW6 12 SW1 4 TH7/6 TH3 TH4 (RED) (WHT) (WHT) CNDM (WHT) 1 LED4 CN51 (WHT) 12 SW4 SWP SW8 3 LED1 1 TH33 TH32 (YLW) (BLK) SW12 LED3 *1 SW5 *1 1 CNS (WHT) LED2 t° LED5 CN2M (WHT) LED1 t° t° LED2 MF1 MS 3~ t° SW11 SW1 1 5 SW9 SW7 t° CNF1 7 (WHT) 5 3 C. B. 1 CN5 (WHT) 63H 1 3 1 SS (WHT) 21S4 RED RED WHT WHT RED WHT N. F. ACL MS 3~ NO PFC 2 CN4 1 (WHT) 2 2 2 CN52C (BLK) CN5 1 (RED) 2 2 1 52C U RED BLK P. B. WHT W V LO MC IPM TABV TABW RED WHT TABS E3 3 TH8 CN3 1 (WHT) 2 1 t° CNAC2 (RED) TABR BLK 5 1 CN5 (RED) TABU CN2 (WHT) CB1 CB2 CB3 1 7 2 2 E2 BLK *1MODEL SELECT CNAC1 (WHT) 3 The black square (■) indicates a switch position. L N NI CY1 CY2 S1 S2 S3 TB1 INDOOR UNIT POWER SUPPLY ~/N 230V 50Hz EI BLK *2. SW5 -1 to 5 : Function Switch U LI YLW 1 2 3 4 5 6 U BRN 1 2 3 4 5 6 ORN 1 2 3 4 5 6 7 8 ON OFF 1 GRN/YLW 71V ON OFF 1 2 3 4 5 6 7 8 SW5-6 *2 ON OFF BLU 60V SW6 ON OFF RED MODEL M-NET ADAPTER SYMBOL TB7 CN5 CND CN2M SW1 SW11 NAME Terminal Block<M-net connection> Connector<Transmission> Connector<Power Supply> Connector<M-NET communication> Switch<Status of communication> Switch<Address setting : 1s digit> 54 SYMBOL SW12 LED1 LED2 LED3 LED4 LED5 NAME Switch<Address setting : 10s digit> LED<Power Supply : DC5V> LED<Connection to Outdoor Unit> LED<Transmission : Sending> LED<Transmission : Receiving> LED<Power Supply : DC12V> PUHZ-RP100VKA PUHZ-RP125VKA PUHZ-RP140VKA SYMBOL LI NI P2 N2 DCL1,DCL2 IGBT EI,E2,E3,E4 C.B. SW1 NAME Connection Terminal<L-Phase> Connection Terminal<N-Phase> Connection Terminal Connection Terminal Connection Terminal<Reactor> Power Module Connection Terminal<Ground> Controller Circuit Board Switch<Forced Defrost, Defect History Record Reset, Refrigerant Address> Switch<Test Operation> Switch<Function Switch> Switch<Model Select> Switch<Function Setup> Switch<Function Setup> Switch SW4 SW5 SW6 SW7 SW8 SW9 SYMBOL SWP CN31 CN51 SS CNM CNMNT CNVMNT CNDM LED1, LED2 F1~F4 X51,X52 RP140 only LEV-C M M TH33 TH32 TH7 TH6 TH3 TH4 C. B. t° t° t° t° 3 12 t° t° 12 2 1 CNF2 (WHT) 1 1 TRANS 2 CNDC 1 (PNK) CN2 (WHT) LEV-B (RED) 1 1 1 5 CNVMNT CNMNT (WHT) (WHT) LEV-C 6 (BLU) 1 14 CNM (WHT) CN52C (RED) CN4 (WHT) 7 3 1 1 2 3 F1 3 1 2 21S4 3 (GRN) F4 4 X51 F3 CNAC (WHT) 1 1 3 SW12 LED4 2 1 M-NET ADAPTER CN2M (WHT) CND (WHT) 3 1 CN31 3 2 LED3 *1 7 F2 3 3 63H (YLW) 3 CNS (WHT) *1 6 X52 1 LEV-A (WHT) 1 CNDM (WHT) TH33 TH32 TH7/6 TH3 TH4 (YLW) (BLK) (RED) (WHT) (WHT) 7 6 3 3 1 CN51 (WHT) 1 SW5 4 SW4 SWP SW8 1 SW11 CN5 (WHT) SW1 1 LED2 5 5 1 LED1 1 CNF1 (WHT) LED2 5 A B S TB7 M-NET 1 1 SS (WHT) 21S4 2 P. B. 1 2 CN4 (WHT) 1 CN2 (WHT) CN52C 3 (RED) 1 7 52C 52C BLK 2 WHT E3 CNDC (PNK) N2 3 1 CB CNAC2 (RED) 1 P2 RED IGBT 3 BLK E2 1 3 CNAC1 (WHT) E4 W V U DCL2 DCL W V U MS 3~ DCL1 EI *1. MODEL SELECT ON 100V OFF ON 125V OFF ON 140V OFF L SW6 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 LI BLU N S1 S2 BRN GRN/YLW YLW ORN M-NET ADAPTER MC MODEL NI U U BLK BLK RED MF2 MS 3~ 5 5 3 5 7 BLK WHT RED MF1 MS 3~ When M-NET adapter is connected M SW6 LEV-B SW9 SW7 LEV-A SW1 63H NAME Switch<Pump Down> Connector<Emergency Operation> Connector<Connection for Option> Connector<Connection for Option> Connector<A-Control Service Inspection Kit> Connector <Connected to Optional M-NET Adapter Board> Connector <Connected to Optional M-NET Adapter Board> Connector < Connected for Option (Contact Input)> LED<Operation Inspection Indicators> Fuse< T6.3AL250V> Relay LED1 NAME Terminal Block<Power Supply, Indoor/Outdoor > Motor for Compressor Fan Motor Solenoid Valve (Four-Way Valve) High Pressure Switch Thermistor<Outdoor Pipe> Thermistor<Discharge> Thermistor<Outdoor 2-Phase Pipe> Thermistor<Outdoor> Thermistor<Shell> Electronic Expansion Valve Reactor Main Smoothing Capacitor Capacitor Power Circuit Board Connection Terminal<U/V/W-Phase> LED5 SYMBOL TB1 MC MF1, MF2 21S4 63H TH3, TH33 TH4 TH6 TH7 TH32 LEV-A, LEV-B, LEV-C DCL CB CY1,CY2 P.B. U/V/W S3 TB1 SW5-6 *2 ON OFF ON OFF ON OFF INDOOR UNIT 1 2 3 4 5 6 1 2 3 4 5 6 POWER SUPPLY ~/N 230V 50Hz 1 2 3 4 5 6 *2. SW5 -1 to 5 : Function Switch The black square (■) indicates a switch position. 55 CY1 CY2 SYMBOL TB7 CN5 CND CN2M SW1 SW11 SW12 LED1 LED2 LED3 LED4 LED5 NAME Terminal Block<M-net connection> Connector<Transmission> Connector<Power Supply> Connector<M-NET communication> Switch<Status of communication> Switch<Address setting : 1s digit> Switch<Address setting : 10s digit> LED<Power Supply : DC5V> LED<Connection to Outdoor Unit> LED<Transmission : Sending> LED<Transmission : Recelving> LED<Power Supply : DC12V> PUHZ-RP100YKA PUHZ-RP125YKA PUHZ-RP140YKA SYMBOL TB1 TB2 MC MF1, MF2 21S4 63H TH3, TH33 TH4 TH6 TH7 TH32 LEV-A,LEV-B,LEV-C ACL1~ACL4 CB1, CB2 CK RS P.B. TB-U/V/W TB-L1/L2/L3 NAME Terminal Block<Power Supply > Terminal Block<Indoor/Outdoor > Motor for Compressor Fan Motor Solenoid Valve (Four-Way Valve) High Pressure Switch Thermistor<Outdoor Pipe> Thermistor<Discharge> Thermistor<Outdoor 2-Phase Pipe> Thermistor<Outdoor> Thermistor<Shell> Electronic Expansion Valve Reactor Main Smoothing Capacitor Capacitor Rush Current Protect Resistor Power Circuit Board Connection Terminal<U/V/W-Phase> Connection Terminal<L1/L2/L3-Power Supply> SYMBOL TB-P2 TB-C1 TB-N1 X52A N.F. LI1/LI2/LI3/NI LO1/LO2/LO3/NO GD1, GD3 CONV.B. L1-A1/IN L1-A2/OU L2-A2/OU L3-A2/OU N-IN CK-OU C.B. SW1 NAME Connection Terminal Connection Terminal Connection Terminal 52C Relay Noise Filter Circuit Board Connection Terminal<L1/L2/L3/N-Power Supply> Connection Terminal<L1/L2/L3/N-Power Supply> Connection Terminal<Ground> Converter Circuit Board Connection Terminal<L1-Power Supply> Connection Terminal<L1-Power Supply> Connection Terminal<L2-Power Supply> Connection Terminal<L3-Power Supply> Connection Terminal Connection Terminal Controller Circuit Board Switch<Forced Defrost, Defect History Record Reset, Refrigerant Adress> Switch<Test Operation> SW4 SYMBOL SW5 SW6 SW7 SW8 SW9 SWP CN31 LED1,LED2 F1~F4 CNM CNMNT CNVMNT CNDM CN3S CN51 X51,X52 NAME Switch<Function Switch> Switch<Model Select> Switch<Function Setup> Switch<Function Setup> Switch Switch<Pump Down> Connector<Emergency Operation> LED<Operatiion Inspection Indicators> FUSE<T6.3AL250V> Connector<A-Control Service Inspection Kit> Connector <Connect to Optional M-NET Adapter Board> Connector <Connect to Optional M-NET Adapter Board> Connector < Connection for Option(Contact Input)> Connector< Connection for Option> Connector< Connection for Option> Relay RP140 only LEV-C 5 CNF2 (WHT) 1 1 3 63H (YLW) TRANS 1 LEV-A (WHT) 6 1 5 6 LEV-B (RED) 1 3 1 5 CNVMNT CNMNT (WHT) (WHT) 1 LEV-C 6 (BLU) 1 14 CNM (WHT) CN4 (WHT) 1 2 CN2 (WHT) 7 1 CNDC (PNK) 2 3 1 3 TB7 M-NET 1 1 SS (WHT) 7 7 V MS 3~ RED + + RED CB1 + CB2 3 3 1 CK CONV.B. L1-IN L1-A1 RED + TB-N1 TB-C1 WHT TB-P2 2 2 1 BLU CNAC2 3 (RED) RED CNCT (RED) 1 3 RED N.F. CNAC1 (WHT) 1 ACL1 TB1 POWER SUPPLY 3N~ 400V 50Hz L2 L3 N RED LI1 WHT LI2 U BLK BLU LI3 NI LO1 RED U LO2 WHT U LO3 BLK U NO BLU GRN/YLW CNDC (PNK) 1 3 2 3 ACL3 *1. MODEL SELECT MODEL ON 100Y OFF U -1 CNL (BLU) WHT BLK BLK GD3 BRN GD1 ACL2 + + U L1-A2 WHT TB-L1 BLK CK-OU BLK TB-L2 L2-A2 -- TB-L3 RED RED TB-U + X52A WHT U -- 2 CN5 1 (RED) W MC BLK TB-V RS ORN TB-W + L1-OU RED CN2 (WHT) N-IN YLW 1 2 CN4 1 (WHT) RED L1 ACL4 ON 125Y OFF M-NET ADAPTER TB7 CN5 CND CN2M SW1 SW11 CND (WHT) 3 1 A B S 5 L3-A2 WHT 3 BRN S3 3 1 L2-OU WHT 2 S2 M-NET ADAPTER 2 1 CN7 (WHT) BLK BLU 2 INDOOR UNIT 3 SW12 LED3 LED4 21S4 1 3 CN7 (WHT) S1 1 21S4 (GRN) 3 4 P.B. TB2 X51 X52 3 SW11 SW1 LED2 BLK 1 F4 BLK F1 CNS (WHT) 3 F3 CNAC (WHT) 1 2 1 CN31 CN51 (WHT) 7 F2 SW6 1 2 21 TH3 TH4 (WHT) (WHT) SW1 1 4 TH7/6 (RED) SW5 1 3 1 2 TH33 TH32 (YLW) (BLK) 5 *1 LED5 CN2M (WHT) LED1 5 t° *1 3 2 5 CNDM CN3S (WHT) (WHT) 7 MS 3~ When M-NET adapter is connected 3 SW4 SWP SW8 1 MF2 t° M LED1 MS 3~ t° t° LED2 1 MF1 t° M SW7 t° CNF1 7 (WHT) LEV-B M L3-OU BLK C.B. LEV-A SW9 TH33 TH32 TH7 TH6 TH3 TH4 CN5 (WHT) 63H Terminal Block<M-NET connection > Connector<Transmission> Connector<Power Supply> Connector<M-NET communication> Switch<Status of communication> Switch<Address setting: 1s digit> SW12 LED1 LED2 LED3 LED4 LED5 Switch<Address setting. 10s digit > LED<Power Supply: DC5V> LED<Connection to Outdoor Unit> LED<Transmission: Sending> LED<Transmission: Receiving> LED<Power Supply: DC12V> 56 ON 140Y OFF SW6 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 SW5-6 *2 ON OFF ON OFF ON OFF 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 *2. SW5 -1 to 5 : Function Switch The black square (■) indicates a switch position. PUHZ-RP200YKA PUHZ-RP250YKA SYMBOL TB1 TB2 MC MF1,MF2 21S4 63H,63H1,63H2 TH3 TH4 TH6 TH7 TH32 LEV-A,LEV-B ACL4 DCL CB1,CB2 RS FUSE1, FUSE2 CY1,CY2 NAME Terminal Block<Power Supply> Terminal Block<Indoor/Outdoor> Motor for Compressor Fan Motor Solenoid Valve (Four-Way Valve) High Pressure Switch Thermistor<Outdoor Pipe> Thermistor<Discharge> Thermistor<Outdoor 2-Phase Pipe> Thermistor<Outdoor> Thermistor<Shell> Electronic Expansion Valve Reactor Reactor Main Smoothing Capacitor Rush Current Protect Resistor Fuse<T15AL250V> Capacitor SYMBOL P.B. SC-U/V/W TB-L1/L2/L3 TB-P1 TB-P2 TB-C1 TB-N1 X52A N.F. LI1/ LI2/LI3/NI LO1/ LO2/LO3 GD1,GD2 C.B. SW1 NAME Power Circuit Board Connection Terminal<U/V/W-Phase> Connection Terminal<L1/L2/L3-Power supply> Connection Terminal Connection Terminal Connection Terminal Connection Terminal 52C Relay Noise Filter Circuit Board Connection Terminal<L1/L2/L3/NI-Power supply> Connection Terminal<L1/L2/L3-Power supply> Connection Terminal<Ground> Controller Circuit Board Switch<Forced Defrost, Defect History Record Reset, Refrigerant Address> Switch<Test Operation> Switch<Function Switch> Switch<Model Select> SW4 SW5 SW6 SYMBOL SW7 SW8 SW9 SWP CN31 LED1,LED2 F3,F4 SS CNM CNMNT CNVMNT CNDM CN3S CN51 X51,X52 NAME Switch<Function Setup> Switch<Function Setup> Switch Switch<Pump Down> Connector<Emergency Operation> LED<Operation Inspection Indicators> Fuse< T6.3AL250V> Connector<Connection for Option> Connector<A-Control Service Inspection Kit> Connector <Connected to Optional M-NET Adapter Board> Connector <Connected to Optional M-NET Adapter Board> Connector < Connected for Option (Contact Input)> Connector<Connection for Option> Connector<Connection for Option> Relay *3. *3. For RP200 For RP250 63H2 5 5 1 3 1 5 CNVMNT CNMNT (WHT) (WHT) CN2 (WHT) 3 1 TRANS 2 1 LED2 1 3 63H (YLW) 1 14 CNM (WHT) CNS (WHT) 1 FUSE1 1 21S4 (GRN) 4 FUSE2 RED WHT 3 X51 X52 3 F4 3 3 1 SW12 LED3 LED4 M-NET ADAPTER 2 1 CN51 (WHT) 7 F3 CNAC (WHT) 1 2 LED2 CN31 2 CNDC (PNK) 1 *1 CN4 (WHT) 1 2 7 SW11 SW1 LED1 6 SW7 LEV-B (RED) SW6 1 SW1 6 LEV-A (WHT) SW5 1 4 12 21 1 2 1 TH32 TH7/6 TH3 TH4 (BLK) (RED) (WHT) (WHT) CNF2 7 (WHT) MS 3~ CN5 (WHT) t° *1 CNF1 7 (WHT) 1 t° 5 CNDM CN3S (WHT) (WHT) MF2 t° When M-NET adapter is connected 3 SW4 SWP SW8 1 MS 3~ t° M LED1 MF1 t° LEV-B M SW9 C. B. LEV-A 63H1 LED5 CN2M (WHT) 63H TH32 TH7 TH6 TH3 TH4 CND (WHT) 3 1 1 3 3 1 3 A B S TB7 1 M-NET 5 SS (WHT) 21S4 P. B. 7 RED WHT 7 CN2 (WHT) 1 2 2 CN4 1 (WHT) 2 CN5 1 (RED) CY2 BLK BLK SC-V WHT SC-U RED TB-L3 BLK TB-L2 WHT TB-L1 RED MC W V MS 3~ U X52A RS CY1 2 SC-W BLK S3 TB-P2 TB-C1 TB-N1 BLK RED DCL BRN S2 INDOOR UNIT RED TB-P1 ORN S1 WHT YLW TB2 CB1 CB2 2 N. F. CNAC1 (WHT) 1 CNCT (RED) 1 3 2 1 CNAC2 3 (RED) TB1 RED LI 1 WHT LI 2 L3 BLK LI 3 U N BLU NI U L1 POWER SUPPLY 3N~ 400V 50Hz L2 U U LO 1 RED LO 2 WHT LO3 BLK *1 MODEL SELECT MODEL GRN/YLW ON 200Y OFF U U SYMBOL TB7 CN5 CND CN2M SW1 SW11 SW12 LED1 LED2 LED3 LED4 LED5 2 3 3 1 CNL (BLU) WHT CNDC 1 (PNK) WHT GD2 BLK M-NET ADAPTER BLK GD1 ACL4 ON 250Y OFF SW6 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 SW5-6 *2 ON OFF ON OFF 1 2 3 4 5 6 1 2 3 4 5 6 *2. SW5 -1 to 5 : Function Switch The black square (■) indicates a switch position. NAME Terminal Block(M-NET connection) Connector<Transmission> Connector<Power Supply> Connector<M-NET communication> Switch<Status of communication> Switch<Address setting:1s digit> Switch<Address setting:10s digit> LED<Power Supply:DC5V> LED<Connection to Outdoor Unit> LED<Transmission:Sending> LED<Transmission:Receiving> LED<Power Supply:DC12V> 57 5 REFRIGERANT SYSTEM DIAGRAM 5-1. INDOOR UNIT PLA-RP·BA/BA2/BA3 PEAD-RP·JA(L) PCA-RP·KA PCA-RP·HA PSA-RP·GA Strainer(#50) Heat exchanger Refrigerant GAS pipe connection (Flare) Thermistor TH5 (Cond./Eva. temperature) Refrigerant flow in cooling Refrigerant flow in heating Distributor Thermistor TH2 with strainer(#50) Pipe temperature (Liquid) Thermistor TH1 (Room temperature) Refrigerant LIQUID pipe connection (Flare) Strainer(#50) PKA-RP·HAL PKA-RP·KAL Strainer (#50) Heat exchanger Refrigerant GAS pipe connection (Flare) Thermistor TH2 Pipe temperature(Liquid) Thermistor TH5 (Cond./ Eva.temperature) Refrigerant flow in cooling Refrigerant flow in heating Refrigerant LIQUID pipe connection (Flare) Thermistor TH1 (Room temperature) Distributor with strainer (#50/#50: HAL) (#50/#100: KAL) 58 Strainer (#50) PEA-RP200, 250GA Strainer Heat exchanger Refrigerant GAS pipe connection Brazing Condenser/evaporator temperature thermistor (TH5) Refrigerant flow in cooling Refrigerant flow in heating Refrigerant LIQUID pipe connection Brazing Room temperature thermistor(TH1) Pie temperature thermistor/Liquid (TH2) Strainer PEA-RP400GA PEA-RP500GA Strainer Heat exchanger Refrigerant GAS pipe connection Brazing Condenser/evaporator temperature thermistor (TH5-2) Refrigerant flow in cooling Refrigerant flow in heating Refrigerant LIQUID pipe connection Brazing Pie temperature thermistor/Liquid (TH2-2) Strainer Strainer Refrigerant GAS pipe connection Brazing Condenser/evaporator temperature thermistor (TH5-1) Refrigerant LIQUID pipe connection Brazing Room temperature thermistor(TH1-1) Pie temperature thermistor/Liquid (TH2-1) Strainer Room temperature thermistor(TH1-2) 59 unit: mm(inch) 5-2. OUTDOOR UNIT PUHZ-RP35VHA4 PUHZ-RP50VHA4 Heat exchanger Stop valve (with service port) Refrigerant GAS pipe connection ø12.7 (1/2F) Thermistor TH6 (Outdoor 2-phase pipe) Charge plug Solenoid valve (Four-way valve) Thermistor TH7 (Outdoor) Strainer #50 Thermistor TH3 (Outdoor pipe) Muffler Distributor High pressure switch 63H Thermistor TH4 (Discharge) Thermistor TH32 (Shell) Linear expansion valve B Compressor Power receiver Linear expansion valve A Stop valve Refrigerant LIQUID pipe connection ø6.35 (1/4F) Strainer #100 Strainer #100 Refrigerant flow in cooling Refrigerant flow in heating PUHZ-RP60VHA4 PUHZ-RP71VHA4 Heat exchanger Stop valve (with service port) Refrigerant GAS pipe connection :15.88(5/8) Thermistor TH33 (Outdoor pipe) 4-way valve Strainer #50 Muffler Charge plug (Low pressure) Charge plug (Higt pressure) Thermistor TH7 (Outdoor) Thermistor TH6 (Outdoor 2-phase pipe) Thermistor TH3 (Outdoor pipe) High pressure switch 63H Distributor Thermistor TH4 (Discharge) Strainer #100 Linear expansion valve B Stop valve (with service port) Refrigerant LIQUID pipe connection :9.52(3/8) Thermistor TH32 (Shell) Power receiver Strainer #100 Compressor Linear expansion valve A Strainer #100 Strainer #100 60 Thermistor TH33 (Outdoor pipe) PUHZ-RP100VKA PUHZ-RP100YKA unit: mm(inch) PUHZ-RP125VKA PUHZ-RP125YKA Heat exchanger Ball valve 4-way valve Strainer #50 Refrigerant GAS pipe connection ø15.88 (5/8) Muffler Charge plug (Low pressure) Thermistor TH7 (Outdoor) Thermistor TH6 (Outdoor 2-phase pipe) Charge plug (Higt pressure) Thermistor TH3 (Outdoor pipe) Distributor High pressure switch 63H Strainer #100 Thermistor TH4 (Discharge) Strainer #100 Linear expansion valve B Stop valve (with service port) Refrigerant LIQUID pipe connection ø9.52 (3/8) Thermistor TH32 (Shell) Power receiver Strainer #100 Thermistor TH33 (Outdoor pipe) Compressor Linear expansion valve A Strainer #100 Strainer #100 Refrigerant flow in cooling Refrigerant flow in heating PUHZ-RP140VKA PUHZ-RP140YKA Heat exchanger Ball valve Refrigerant GAS pipe connection :15.88(5/8) 4-way valve Strainer #50 Muffler Charge plug (Low pressure) Charge plug (Higt pressure) Stop valve (with service port) Refrigerant LIQUID pipe connection :9.52(3/8) Strainer #100 Distributor Thermistor TH4 (Discharge) Strainer #100 Linear expansion valve B Thermistor TH3 (Outdoor pipe) High pressure switch 63H Strainer #100 Thermistor TH7 (Outdoor) Thermistor TH6 (Outdoor 2-phase pipe) Thermistor TH32 (Shell) Power receiver Heat interchange circuit Strainer #100 Thermistor TH33 (Outdoor pipe) Compressor Linear expansion valve A Strainer #100 Linear expansion valve C 61 unit: mm(inch) PUHZ-RP200YKA Heat exchanger Ball valve Thermistor TH6 (Outdoor 2-phase pipe) 4-way valve Strainer #50 Refrigerant GAS pipe connection :25.4(1) Muffler Charge plug (Low pressure) Charge plug (Higt pressure) Refrigerant LIQUID pipe connection :9.52(3/8) Distributor Thermistor TH4 (Discharge) Strainer #100 Stop valve (with service port) Thermistor TH3 (Outdoor pipe) High pressure switch 63H Strainer #100 Linear expansion valve B Thermistor TH7 (Outdoor) Thermistor TH32 (Shell) Strainer #100 Power receiver Compressor Linear expansion valve A Strainer #100 Strainer #100 PUHZ-RP250YKA Refrigerant flow in cooling Refrigerant flow in heating Ball valve Heat exchanger High pressure switch(63H2) Refrigerant GAS pipe :25.4 (1) Thermistor (TH6) 4-way valve Strainer (#50) Muffler Service port (check) Thermistor (TH32) Strainer (Shell) (#100) Stop valve (with service port) Refrigerant LIQUID pipe :12.7 (1/2) Service port (check) Power receiver Thermistor (TH3) High pressure switch (63H1) Thermistor (TH4) (Discharge) Strainer (#100) Strainer (#100) Linear expansion valve B Thermistor (TH7) Compressor Linear expansion valve A Strainer (#100) Strainer (#100) 62 Distributor 6 PERFORMANCE CURVES FOR THE COMBINATION OF OUTDOOR UNIT Cooling capacity 1.4 Cooling capacity ratio Indoor intake air wet-bulb temperature <W.B. :> 1.2 22 1.0 20 18 0.8 0.6 16 -5 0 5 10 15 20 25 30 35 40 46 Outdoor intake air dry-bulb temperature <D.B. > Cooling input 22 20 18 16 Cooling input ratio 1.2 1.0 0.8 0.6 Indoor intake air wet-bulb temperature <W.B. :> 0.4 -5 0 5 10 15 20 25 30 35 40 Outdoor intake air dry-bulb temperature <D.B. > Note : These diagrams show the case where the operation frequency of a compressor is fixed. 63 46 Heating capacity Indoor intake air dry-bulb temperature <D.B. :> Outdoor intake air wet-bulb temperature <W.B. :> Heating input Indoor intake air dry-bulb temperature <D.B. :> Outdoor intake air wet-bulb temperature <W.B. :> Note : These diagrams show the case where the operation frequency of a compressor is fixed. 64 7 CORRECTION FACTORS 7-1. PUHZ-RP·VHA4 PUHZ-RP·VKA PUHZ-RP100-140YKA Cooling capacity correction factors 5m 10m 20m Refrigerant piping length (one way) 30m 40m 50m 55m PUHZ-RP35VHA4 1.00 0.992 0.976 0.962 0.949 0.936 PUHZ-RP50VHA4 1.00 0.985 0.957 0.931 0.908 PUHZ-RP60VHA4 1.00 0.992 0.976 0.962 PUHZ-RP71VHA4 1.00 0.988 0.966 1.00 0.985 1.00 1.00 Outdoor unit PUHZ-RP100VKA PUHZ-RP100YKA PUHZ-RP125VKA PUHZ-RP125YKA PUHZ-RP140VKA PUHZ-RP140YKA 60m 70m 80m 0.930 — — — 0.886 0.876 — — — 0.949 0.936 0.930 — — — 0.946 0.929 0.913 0.905 — — — 0.957 0.931 0.908 0.886 0.876 0.865 0.846 0.829 0.981 0.946 0.914 0.885 0.858 0.845 0.834 0.812 0.792 0.976 0.931 0.893 0.858 0.827 0.813 0.800 0.775 0.753 60m 70m 80m Heating capacity correction factors 5m 10m 20m Refrigerant piping length (one way) 30m 40m 50m 55m PUHZ-RP35VHA4 1.00 0.997 0.991 0.985 0.979 0.973 0.970 — — — PUHZ-RP50VHA4 1.00 0.997 0.991 0.985 0.979 0.973 0.970 — — — PUHZ-RP60VHA4 1.00 0.997 0.991 0.985 0.979 0.973 0.970 — — — PUHZ-RP71VHA4 1.00 0.997 0.991 0.985 0.979 0.973 0.970 — — — 1.00 0.997 0.991 0.985 0.979 0.973 0.970 0.967 0.961 0.955 1.00 0.997 0.991 0.985 0.979 0.973 0.970 0.967 0.961 0.955 1.00 0.997 0.991 0.985 0.979 0.973 0.970 0.967 0.961 0.955 Outdoor unit PUHZ-RP100VKA PUHZ-RP100YKA PUHZ-RP125VKA PUHZ-RP125YKA PUHZ-RP140VKA PUHZ-RP140YKA 7-2. PUHZ-RP200, 250YKA Cooling capacity correction factors Outdoor unit Refrigerant piping length (one way) 5m 10m 20m 30m 40m 50m 55m 60m PUHZ-RP200YKA 1.00 0.985 0.958 0.931 0.908 0.887 0.876 0.865 PUHZ-RP250YKA 1.00 0.981 0.946 0.914 0.885 0.858 0.845 0.834 Outdoor unit Refrigerant piping length (one way) 70m 75m 80m 90m 100m 110m 120m 125m PUHZ-RP200YKA 0.847 0.838 0.829 0.815 0.800 0.790 0.780 0.778 PUHZ-RP250YKA 0.812 0.802 0.792 0.772 0.758 0.743 0.730 0.725 Heating capacity correction factors Outdoor unit PUHZ-RP200YKA PUHZ-RP250YKA Outdoor unit PUHZ-RP200YKA PUHZ-RP250YKA 5m 10m Refrigerant piping length (one way) 20m 30m 40m 50m 55m 60m 1.00 0.997 0.991 0.973 0.970 0.967 70m 75m Refrigerant piping length (one way) 80m 90m 100m 110m 120m 125m 0.961 0.958 0.955 0.931 0.928 0.985 0.949 65 0.979 0.943 0.937 8 APPLICABLE EXTENSION PIPE FOR EACH MODEL 8-1. PUHZ-RP·VHA4 PUHZ-RP·VKA PUHZ-RP100-140YKA 8-1-1. PIPE LENGTH (1) 1:1 SYSTEM Pipe length <Table 1> Maximum pipe length OD Thickness OD Thickness Liquid pipe (mm) Gas pipe (mm) RP35•50 :6.35 t0.8 :9.52 :12.7 t0.8 t0.8 Standard size 30m +1 50m [30m] [30m] 10m [10m] RP60•71 :15.88 t1.0 +2 30m [30m] :12.7 t0.8 10m [10m] 30m [30m] :9.52 t0.8 :15.88 t1.0 +2 30m [20m] Standard size 50m [30m] Standard size 50m +3 [30m] 30m [20m] RP100~140 :19.05 t1.0 :12.7 t0.8 :19.05 :15.88 t1.0 t1.0 <Marks in the table> : It can be used. : Cooling capacity is lowered. : Additional refrigerant charge is required when the pipe length exceeds 20m. 50m [30m] 50m [20m] The maximum pipe length Charge-less pipe length 50m [30m] 30m [20m] 50m [20m] +1. RP50 : maximum pipe length is 10m. +2. Change the SW8-1 on the outdoor controller circuit board from OFF to ON. +3. The maximum length is 75m in case of new pipes. (2) TWIN AND TRIPLE SYSTEM (a) TWIN SYSTEM (b) TRIPLE SYSTEM <Table 2> Maximum pipe length <Table 3> Maximum pipe length RP71(RP35%2) Main pipe (mm) [A] Liquid pipe Gas pipe Liquid pipe :6.35 Gas pipe :12.7 :6.35 :12.7 Branch pipe Liquid pipe :9.52 (mm) Gas pipe :15.88 [B, C] Liquid pipe :12.7 Gas pipe RP100(RP50%2) :9.52 :9.52 :15.88 :15.88 Standard size Standard size 50m 50m + [30m] [30m] 50m [30m] :9.52 :19.05 :12.7 :19.05 50m [30m] 50m [20m] 50m [30m] 50m [20m] 50m [30m] RP125(RP60%2) • RP140(RP71%2) :9.52 :15.88 Standard size 50m + [30m] :9.52 :19.05 50m [30m] RP140(RP50%3) :12.7 :19.05 Main pipe (mm) [A] 50m [20m] Branch pipe Liquid pipe ø9.52 (mm) Gas pipe ø15.88 [B, C, D] ø9.52 ø9.52 ø15.88 ø19.05 Gas pipe Liquid pipe ø6.35 Standard size 50m + 50m Gas pipe ø12.7 [30m] [30m] Liquid pipe 50m [20m] Gas pipe ø19.05 + The maximum length is 75m in case of new pipes. + The maximum length is 75m in case of new pipes. Indoor unit side Indoor unit side Indoor unit Indoor unit Indoor unit B h B C Indoor unit C D Indoor unit H H Outdoor unit Distribution pipe 50m [30m] 50m [20m] Liquid pipe ø12.7 :19.05 h 50m [30m] ø12.7 ø19.05 Distribution pipe Outdoor unit side Outdoor unit side A A <TRIPLE SYSTEM> Total length A + B + C + D RP140: 75 m <TWIN SYSTEM> Total length A + B + C RP71 : 50 m RP100-140: 75 m 66 Outdoor unit 8-1-2. ADJUSTING THE AMOUNT OF REFRIGERANT • Check additional refrigerant charging amount referring to table 5, 6 when liquid pipe is 1 size larger than standard diameter. <Table 5> Required additional charge when the pipe size is 1 size larger than the standard diameter (1:1 SYSTEM) Liquid pipe O.D. Refrigerant amount to be added PUHZ-RP35,50 :9.52 60 g per 1 m PUHZ-RP60,71 :12.7 100 g per 1 m PUHZ-RP100~140 :12.7 100 g per 1 m Outdoor unit <Table 6> Required additional charge when the pipe size is 1 size larger than the standard diameter (TWIN/TRIPLE SYSTEM) Outdoor unit When the extension pipe length (main piping + branch piping) exceeds 20 m PUHZ-RP71~140 Additional refrigerant amount W(g) = (100 % L1) + (60 % L2) + (30 % L3) - 2000 If the calculation produces a negative number ( W 0), additional charging is not necessary. L1: :12.7 liquid pipe length (m) L2: :9.52 liquid pipe length (m) L3: :6.35 liquid pipe length (m) <Table 7> Additional refrigerant charging amount for pipe of standard diameter Additional refrigerant charging amount Permitted Amount of unit for pipe length exceeding 30 m (kg) Type Outdoor unit pipe length filling refrigerant (kg) 31 – 40m 41 – 50m 51 – 60m 61 – 70m 71 – 75m 1:1 PUHZ-RP35,50 system PUHZ-RP71 PUHZ-RP100~140 Type Outdoor unit Twin Triple PUHZ-RP71 system PUHZ-RP100~140 50m or less 2.5kg 0.2kg 0.4kg 3.5kg 0.6kg 1.2kg 75m or less 5.0kg 0.6kg 1.2kg Permitted pipe length Amount of unit filling refrigerant (kg) 50m or less 75m or less 2.4kg Additional refrigerant charging amount for pipe length exceeding 30 m (kg) 31 – 40m 41 – 50m 3.5kg 0.6kg 1.2kg 5.0kg 0.6kg 1.2kg 67 1.8kg 51 – 60m 1.8kg 61– 70m 71 – 75m 2.4kg 8-1-3. CAPACITY CORRECTION CURVES Cooling and heating capacity is lowered according to pipe length. Capacity can be obtained by referring to the capacity curves below. When the diameter of gas pipe is 1 size smaller than standard diameter, cooling capacity is lowered comparing to the standard diameter. The lowered capacity can be obtained by referring to capacity curves for gas pipe which is 1 size smaller than standard size. Corrected pipe length (m) = actual pipe length (m) + number of bends x 0.3 (m) [Sample calculation] Indoor unit RP60 o 2 units (Twin system) Outdoor unit RP125 o 1 ■ Condition Using existing pipes. • Outdoor unit side Liquid pipe [12.7 / Gas pipe [19.05 pipe length (A) 20m • Indoor unit side Liquid pipe [9.52 / Gas pipe [15.88 pipe length (B) 20m + (C) 15m 1) Farthest piping length 20m + 15m = 35m Number of bends : 10 2) Corrected piping length 35m + 0.3 o 10 = 38m 3) Capacity correction Outdoor unit side’s gas pipe [19.05 Standard [15.88 → 1 size up Refer to 1 Capacity curves <Standard size> 4) Capacity Cooling capacity = Standard cooling capacity o 0.89 Heating capacity = Standard heating capacity o 0.98 1 Capacity curves for PUHZ-RP · HA2 model <Standard size> Cooling Heating 100 Heating RP35, 50, 60, 71, 100, 125 and 140 models (Up to 55m for RP35, 50, 60, 71 models) 95 Capacity ratio [%] Cooling RP35, 60 models Cooling RP71 model 90 85 Cooling RP50, 100 models 80 Cooling RP125 model Cooling RP140 model 75 Note: The permitted pipe length is up to 55m for RP35, 50, 60, 71 model. The permitted pipe length is up to 80m for RP100 ~ 140 model. 70 5 10 15 20 25 30 35 40 45 50 55 Corrected pipe length [m] 68 60 65 70 75 80 2 Capacity curve for PUHZ-RP35, 50 models <When gas pipe is 1 size smaller than standard size> Cooling Heating 100 Heating RP35, RP50 (:9.52) Capacity ratio [%] 95 90 Cooling RP50 (:9.52) 85 Cooling RP35 (:9.52) 80 5 10 15 20 25 30 35 Corrected pipe length [m] 3 Capacity curve for PUHZ-RP60, 71 models <When gas pipe is 1 size smaller than standard size> 100 Heating RP60, RP71 (:12.7) Capacity ratio [%] 95 90 85 80 Cooling RP60,RP71 (:12.7) 5 10 15 20 25 30 35 Corrected pipe length [m] 4 When gas pipe is one size larger than standard size for PUHZ-RP100, 125 and 140. 1 Capacity can be obtained by referring to capacity curves of standard size. 69 8-2. PUHZ-RP200·250YKA 8-2-1. 1:1 SYSTEM (1) Pipe length <Table 1> Maximum pipe length (RP200·RP250) Liquid pipe (mm) O.D. :9.52 :12.7 :15.88 Thickness t0.8 t0.8 t1.0 Gas pipe (mm) O.D. :19.05 :22.2 :25.4 :28.58 :19.05 :22.2 :25.4 :28.58 :22.2 :25.4 :28.58 :31.75 Thickness t1.0 t1.0 t1.0 t1.0 t1.0 t1.0 t1.0 t1.0 t1.0 t1.0 t1.0 t1.1 RP200 20m [20m] 50m [30m] 120m [30m] 120m [30m] 20m [20m] 50m [30m] 120m [30m] 120m [30m] 50m [20m] 50m [20m] 50m [20m] 50m [20m] RP250 20m [20m] 50m [30m] 120m [30m] 120m [30m] 20m [20m] 50m [30m] Standard size 120m [30m] 120m [30m] 50m [20m] 50m [20m] 50m [20m] 50m [20m] Standard size Note : Be sure to use hard (tempered) one for pipe over :22.2(RP200)/:19.05(RP250). <Marks in the table above> : It can be used. : Cooling capacity is lowered. : Additional refrigerant charge is required when the pipe length exceeds 20m. 120m [30m] The maximum pipe length Charge-less pipe length (2) Adjusting the amount of refrigerant Check additional refrigerant charging amount referring to table 7 when the liquid pipe diameter is 1 size larger than the standard size, and table 2 when the pipe of the standard diameter is used. <Table 2> Outdoor unit RP200 RP250 permitted pipe length 120m or less Initial charge (kg) Amount of additional refrigerant charge (kg) 30 m and less 7.1 No additional charge necessary 7.7 31-40 m and less 41-50 m and less 51-60 m and less 61-70 m and less 71-120 m and less The additional charge 0.9 kg 1.8 kg 2.7 kg 3.6 kg 1.2 kg 2.4 kg 3.6 kg amount is obtained by the following formula. 4.8 kg When length exceeds 70 m When the total length of the piping exceeds 70 m, calculate the amount of additional charge based on the following requirements. Note: If the calculation produces a negative number (i.e. a “minus” charge), of if calculation results in an amount that is less than the “Additional charage amount for 70 m”, perform the additional charge using the amount shown in “Additional charge amount for 70 m”. Amount of additional charge (kg) = Main piping: Liquid line size ø12.7 overall length × 0.11 (m) × 0.11 (kg/m) + Main piping: Liquid line size ø9.52 overall length × 0.09 (Gas line: ø25.4) + Branch piping: Liquid line size ø9.52 overall length × + 0.06 (Gas line: ø15.88) (m) × 0.06 (kg/m) (m) × 0.09 (kg/m) Branch piping: Liquid line size ø6.35 overall length × 0.02 – 3.6 (kg) (m) × 0.02 (kg/m) Additional charge amount RP200 3.6 kg for 70 meters RP250 4.8 kg •If the wiring connecting the indoor and outdoor units is longer than 80m, use separate indoor /outdoor unit power supplies. 70 (3) Capacity correction Cooling and heating capacity is lowered according to the piping length. Capacity can be obtained by referring to the following capacity curves. When the diameter of the gas pipe is smaller than the standard size, cooling capacity is lowered comparing to the operation using the standard diameter pipe. The lowered capacity can be obtained by referring to the capacity curves for gas pipe which is 1 or 2 size smaller than standard size. Corrected pipe length (m) = actual pipe length (m) + number of bends o 0.3 (m) 1. Capacity curves 1 <Standard size> Cooling Heating 100 Capacity ratio [%] 95 RP200,250 90 85 80 RP200 75 RP250 70 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 Corrected pipe length [m] 2. Capacity curves 2 <When the gas pipe's diameter is 1-size-smaller than the standard size> Cooling Heating 100 RP200, 250(:22.2) Capacity ratio [%] 95 90 85 80 RP200(:22.2) 75 70 7.5 10 RP250(:22.2) 15 20 25 30 35 40 45 50 55 Corrected pipe length [m] 3. Capacity curves 3 <When the gas pipe's diameter is 2-size-smaller than the standard size> Cooling Heating 100 RP200, 250(:19.05) Capacity ratio [%] 95 90 w RP250 Use 1/2H or H pipes if the diameter is 19.05. 85 80 RP200(:19.05) RP250(:19.05) 75 70 7.5 10 15 20 Corrected pipe length [m] 25 71 2. TWIN, TRIPLE AND QUADRUPLE SYSTEM (1) Twin Maximum pipe length (Main pipe [A] + Branch pipe diameter [ B and C ]) RP200 twin (RP1002) RP250 twin (RP1252) :9.52 :12.7 :15.88 :9.52 :12.7 :15.88 :19.05 :22.2 :25.4 :28.58 :19.05 :22.2 :25.4 :28.58 :22.2 :25.4 :28.58 :31.75 :19.05 :22.2 :25.4 :28.58 :19.05 :22.2 :25.4 :28.58 :22.2 :25.4 :28.58 :31.75 Liquid pipe Gas pipe Main pipe (mm)[A] Liquid pipe Gas pipe Liquid pipe Branch pipe Gas pipe [mm] Liquid pipe [B, C] Gas pipe :9.52 Standard size Standard size 20m 50m 120m 120m 20m 50m 120m 120m 50m 50m 50m 50m 20m 50m 120m 120m 20m 50m 120m :15.88 [20m] [30m] [30m] [30m] [20m] [30m] [30m] [30m] [20m] [20m] [20m] [20m] [20m] [30m] [30m] [30m] [20m] [30m] [30m] 50m 50m 50m 120m 50m [30m] [20m] [20m] [20m] [20m] :9.52 20m 50m 120m 120m 20m 50m 120m 120m 50m 50m 50m 50m 20m 50m 120m 120m 20m 50m 120m 120m 50m 50m 50m 50m :19.05 [20m] [30m] [30m] [30m] [20m] [30m] [30m] [30m] [20m] [20m] [20m] [20m] [20m] [30m] [30m] [30m] [20m] [30m] [30m] [30m] [20m] [20m] [20m] [20m] :12.7 20m 50m 120m 120m 20m 50m 120m 120m 50m 50m 50m 50m 20m 50m 120m 120m 20m 50m 120m 120m 50m 50m 50m 50m :19.05 [20m] [30m] [30m] [30m] [20m] [30m] [30m] [30m] [20m] [20m] [20m] [20m] [20m] [30m] [30m] [30m] [20m] [30m] [30m] [30m] [20m] [20m] [20m] [20m] • Be sure to use hard (tempered) one for pipe over :22.2(RP200)/:19.05(RP250). (2) Triple Maximum pipe length (Main pipe [A] + Branch pipe [ B, C and D ]) Main pipe (mm)[A] RP200 triple (RP603) RP250 triple (RP713) :9.52 :12.7 :15.88 :9.52 :12.7 :15.88 :19.05 :22.2 :25.4 :28.58 :19.05 :22.2 :25.4 :28.58 :22.2 :25.4 :28.58 :31.75 :19.05 :22.2 :25.4 :28.58 :19.05 :22.2 :25.4 :28.58 :22.2 :25.4 :28.58 :31.75 Liquid pipe Gas pipe Liquid pipe Gas pipe Liquid pipe Branch pipe Gas pipe [mm] Liquid pipe [B, C, D] Gas pipe :9.52 Standard size Standard size 20m 50m 120m 120m 20m 50m 120m 120m 50m 50m 50m 50m 20m 50m 120m 120m 20m 50m 120m :15.88 [20m] [30m] [30m] [30m] [20m] [30m] [30m] [30m] [20m] [20m] [20m] [20m] [20m] [30m] [30m] [30m] [20m] [30m] [30m] 50m 50m 50m 120m 50m [30m] [20m] [20m] [20m] [20m] :9.52 20m 50m 120m 120m 20m 50m 120m 120m 50m 50m 50m 50m 20m 50m 120m 120m 20m 50m 120m 120m 50m 50m 50m 50m :19.05 [20m] [30m] [30m] [30m] [20m] [30m] [30m] [30m] [20m] [20m] [20m] [20m] [20m] [30m] [30m] [30m] [20m] [30m] [30m] [30m] [20m] [20m] [20m] [20m] :12.7 20m 50m 120m 120m 20m 50m 120m 120m 50m 50m 50m 50m 20m 50m 120m 120m 20m 50m 120m 120m 50m 50m 50m 50m :19.05 [20m] [30m] [30m] [30m] [20m] [30m] [30m] [30m] [20m] [20m] [20m] [20m] [20m] [30m] [30m] [30m] [20m] [30m] [30m] [30m] [20m] [20m] [20m] [20m] • Be sure to use hard (tempered) one for pipe over :22.2(RP200)/:19.05(RP250). (3) Quadruple Maximum pipe length (Main pipe [A] + Branch pipe [ B, C, D and E ]) Main pipe (mm)[A] RP200 quadruple (RP504) RP250 quadruple (RP604) :9.52 :12.7 :15.88 :9.52 :12.7 :15.88 :19.05 :22.2 :25.4 :28.58 :19.05 :22.2 :25.4 :28.58 :22.2 :25.4 :28.58 :31.75 :19.05 :22.2 :25.4 :28.58 :19.05 :22.2 :25.4 :28.58 :22.2 :25.4 :28.58 :31.75 Liquid pipe Gas pipe Liquid pipe Gas pipe Liquid pipe Branch pipe Gas pipe [mm] Liquid pipe [B, C, D, E] Gas pipe Liquid pipe Gas pipe :6.35 Standard size 20m 50m 120m 120m 20m 50m 120m 120m 50m 50m 50m 50m :12.7 [20m] [30m] [30m] [30m] [20m] [30m] [30m] [30m] [20m] [20m] [20m] [20m] Standard size :9.52 20m 50m 120m 120m 20m 50m 120m 120m 50m 50m 50m 50m 20m 50m 120m 120m 20m 50m 120m :15.88 [20m] [30m] [30m] [30m] [20m] [30m] [30m] [30m] [20m] [20m] [20m] [20m] [20m] [30m] [30m] [30m] [20m] [30m] [30m] 50m 50m 50m 50m [20m] [20m] [20m] [20m] :9.52 20m 50m 120m 120m 20m 50m 120m 120m 50m 50m 50m 50m 20m 50m 120m 120m 20m 50m 120m 120m 50m 50m 50m 50m :19.05 [20m] [30m] [30m] [30m] [20m] [30m] [30m] [30m] [20m] [20m] [20m] [20m] [20m] [30m] [30m] [30m] [20m] [30m] [30m] [30m] [20m] [20m] [20m] [20m] :12.7 20m 50m 120m 120m 20m 50m 120m 120m 50m 50m 50m 50m [20m] [30m] [30m] [30m] [20m] [30m] [30m] [30m] [20m] [20m] [20m] [20m] :19.05 • Be sure to use hard (tempered) one for pipe over :22.2(RP200)/:19.05(RP250). <Marks in the table above> 120m [30m] 120m [30m] : It can be used. : Cooling capacity is lowered. Refer to <Table6>. : Additional refrigerant charge is required when the pipe length exceeds 20m. Refer to <Table7>. The maximum pipe length Charge-less pipe length 72 Pipe diameter and thickness OD (mm) :6.35 Thickness 0.8 (mm) :9.52 :12.7 0.8 0.8 :15.88 :19.05 1.0 :22.2 1.0 1.0 :25.4 :28.58 1.0 :31.75 1.0 1.1 Be sure to use hard (tempered) one for pipe over :19.05(RP250)/:22.2(RP200).(Do not use soft (annealed) one.) B D E Indoor unit Outdoor unit Main piping Branch piping Multi distribution pipe (option) 1 Height difference (Indoor unitOutdoor unit) Max. 30 m 2 Height difference (Indoor unitIndoor unit) Max. 1 m 3 Distance between indoor and indoor units pipe length. Max. 8m 1 2 C B—C B—D B—E C—D C—E D—E A 4 Number of pipe bends Within 15 points 8 points between main pipe A and each branch pipe (B, C, D, E). <Table 6> Lowered cooling capacity by the smaller gas pipe diameter Cooling capacity ratio gas pipe :22.2 gas pipe :19.05 100% 100% 100~95% 100~88% 95~88% 88~77% 88~83% 83~79% 79~75% Pipe length 5m and less 6~10m 11~20m 21~30m 31~40m 41~50m <Table 7> Additional refrigerant amount when the liquid pipe of the larger diameter is used. (Single /Simultaneous Twin / Simultaneous Triple / Simultaneous Quadruple) Capacity When the extension pipe length (main piping + branch piping) exceeds 20m RP200, RP250 Additional refrigerant amount W(g)=(180%L1)+(120%L2) (90%L3)+(30%L4)-3000 L1 : :15.88 liquid pipe (m) L3 : :9.52 liquid pipe (m) L2 : :12.7 liquid pipe (m) L4 : :6.35 liquid pipe (m) If the calculation produces a negative number (i.e. a "minus" charge), additional charging is not necessary. ( W 0) <Table 8> Outdoor unit Permissible total piping length A+B+C+D+E RP200 PR250 120 m and less A+B or A+C or A+D or A+E 100 m and less Charge-less piping length A+B+C+D+E 30 m and less <Table 9> Outdoor unit B-C or B-D or B-E or C-D or C-E or D-E RP200 RP250 8 m and less Number of pipe bends Within 15 73 <Table 10> Outdoor unit Permitted pipe length RP200 At time of shipping (kg) 7.1 120m or less RP250 7.7 30 m and less No additional charge necessary A+B+C+D Amount of additional refrigerant charge (kg) 31-40 m and less 41-50 m and less 51-60 m and less 61-70 m and less 71-120 m and less 0.9 kg 1.8 kg 2.7 kg 3.6 kg 1.2 kg 2.4 kg 3.6 kg 3.6 kg The additional charge amount is obtained by the following formula. When length exceeds 70 m When the total length of the piping exceeds 70 m, calculate the amount of additional charge based on the following requirements. Note: If the calculation produces a negative number (i.e. a “minus” charge), or if calculation results in an amount that is less than the “Additional charge amount for 70 m,” perform the additional charge using the amount shown in “Additional charge amount for 70 m.” Main piping: Amount of additional = Liquid line size charge :12.7 overall length 0.11 + Main piping: Liquid line size :9.52 overall length 0.09 (Gas line::28.58) Branch piping: Liquid Branch piping: Liquid + line size + line size – :9.52 overall length :6.35 overall length 0.06 (Gas line: :15.88) 0.02 (Gas line: :15.88) 3.6 (kg) Additional charge amount RP200 3.6 kg for 70 m RP250 4.8 kg 1. Perform refrigerant piping connections for the indoor / outdoor unit while the outdoor unit's stop valve is completely closed (Initial setting), and then vacuumize the refrigerant lines through the service port of the outdoor unit. 2. Open the stop valves of the outdoor unit completely. This will completely connects the refrigerant circuits of the indoor and outdoor units. Stop valve opening method is shown on the outdoor unit’s installation manual. Note : · Apply refrigerating machine oil over the flare seat surface. Do not apply to the threaded portion. (It will cause the flare nut to loosen.) · Use 2 wrenches to tighten piping connection. · Use leak detector or soapy water to check for gas leaks after connections are completed. · For the insulation of the connection at the indoor side, make sure to use the attached insulation materials and thoroughly follow the instruction shown in the manual. · Always use a non-oxidizing brazing material when brazing the pipes. Adjusting the amount of refrigerant Check additional refrigerant charging amount referring to the procedure 2 below when the liquid pipe diameter of the main piping A is larger than the standard size. 1 When the standard diameter pipe is used for the main piping A, calculate the additional refrigerant amount by referring to <Table 2> as well as the 1:1 system. 2 When the liquid pipe diameter of the main piping A is one size larger than the standard size: · When the extension pipe length (main piping + branch piping) does not exceed 20m, adjustment of the refrigerant is not necessary (charge-less). · When the extension pipe length (main piping + branch piping) exceeds 20m, charge the amount of refrigerant that is obtained by the formula shown in <Table 7>. If the calculation produces a negative number (i.e. a "minus" charge), additional charging is not necessary. Note: Apply 0 to L1, L2, L3 and L4 which correspond to the liquid pipe size that are not used. Correcting the capacity value When calculating the lowered capacity by the extension pipe length, use the longest length between the indoor and the outdoor units. 74 9 AIR FLOW DATA 9-1. OUTLET AIR SPEED AND COVERAGE RANGE Airflow m3/min. 15 18 18 PLA-RP71BA PLA-RP71BA2 21 Air speed m/sec. 2.6 3.2 3.2 3.7 5.3 5.4 5.6 m 4.1 4.8 4.8 5.6 8.0 8.2 8.5 PLA-RP35BA Coverage range PLA-RP50BA PCA-RP50KA PLA-RP60BA PCA-RP60KA PLA-RP100BA PLA-RP125BA PLA-RP140BA2 PLA-RP100BA3 PLA-RP125BA2 30 31 32 PCA-RP71KA PCA-RP100KA PCA-RP125KA PCA-RP140KA Airflow m3/min. 15 19 20 28 29 32 Air speed m/sec. 3.3 3.1 3.2 3.6 3.7 4.1 m 9.0 9.6 10.1 12.5 12.9 14.2 Coverage range PCA-RP71HA PCA-RP125HA Airflow m3/min. 19 38 Air speed m/sec. 2.9 4.2 m 7.9 13.2 PKA-RP35HAL PKA-RP50HAL Coverage range Airflow m3/min. 12 12 Air speed m/sec. 6.1 6.1 m(ft) 10.8(35.4) 10.8(35.4) PKA-RP60KAL PKA-RP71KAL Coverage range PKA-RP100KAL Airflow m3/min. 22 22 26 Air speed m/sec. 6.0 6.0 6.8 m(ft) 14.3(46.9) 14.3(46.9) 16.1(52.8) PSA-RP71GA PSA-RP100GA PSA-RP125GA PSA-RP140GA Coverage range Airflow m3/min. 18 31 33 35 Air speed m/sec. 2.6 4.5 4.8 4.9 m 8.3 14.3 15.2 16.1 Coverage range w The air coverage range is the distance to which the 0.25m/sec air can reach, when air is blown out horizontally from the unit at the High notch position. The coverage range should be used only as a general guideline since it varies according to the size of the room and the furniture inside the room. 75 9-2. PLA-RP·BA/BA2/BA3 9-2-1 FRESH AIR INTAKE AND BRANCH DUCT 1. Branch duct hole and fresh air intake hole (Fig. 1) At the time of i nstallation, use the duct holes ( cut out) located at the positions shown in Fig.1, as and when required. • A fresh air intake hole for the optional multi function casement can also be made. Note: The figure marked with * in the drawing represent the dimensions of the main unit excluding those of the optional multi function casement. When installing the optional multi function casement, add 135 mm to the dimensions marked on the figure. When installing the branch ducts, be sure to insulate adequately. Otherwise condensation and dripping may occur. Unit:mm Fresh air intake hole Fresh air intake hole diagram Branch duct hole 3-:2.8 burring hole :125 burring hole pitch 120 120 Indoor unit *158 :100 cut out hole Ceiling Drain pipe Refrigerant pipe 100 100 90 130 90 Branch duct hole diagram (view from either side) 100 350 :175 burring hole pitch Fig. 1 76 *167 70 *155 14-:2.8 burring hole :150 cut out hole 3. Fresh air intake volume & static pressure characteristics PLA-RP35~71BA(2) At using multi-function casement, standard filter 50 Static pressure[Pa] 0 -50 2 - inlet -100 -150 1 - inlet -200 0 1 2 3 4 5 6 Airflow rate [m3/min] At using multi-function casement, high efficiency filter 50 0 0 Static pressure[Pa] Static pressure[Pa] Direct intake to unit 50 -50 -100 -150 -200 0 1 2 3 4 5 -50 -100 -150 -200 6 2 - inlet 1 - inlet 0 1 2 3 Airflow rate [m3/min] 3 Airflow rate [m /min] 4 5 6 PLA-RP100BA(3), PLA-RP125,140BA(2) At using multi-function casement, standard filter 50 Static pressure[Pa] 0 -50 2 - inlet -100 -150 1 - inlet -200 0 2 4 Airflow rate [m3/min] 6 8 At using multi-function casement, high efficiency filter Direct intake to unit 50 50 0 Static pressure[Pa] Static pressure[Pa] 0 -50 -100 -150 -50 -100 2 - inlet -150 1 - inlet -200 0 2 4 Airflow rate [m3/min] 6 -200 8 77 0 2 4 Airflow rate [m3/min] 6 8 4. Change of outlet numbers Indoor unit The optional air outlet is necessary. To change the air outlet number to 3-, or 2-way outlet, the outlet number should be closed with the operational air outlet shutter. When the air outlets are closed, close the vane by removing the vane connector. Outlet concave portion Button Vane motor Up/down vanes Connector Air outlet shutter plate (Option) Vane motor Connector Button 5. Branch duct and change of outlet numbers + Branch duct should be connected to one of the branch duct holes on the main unit. <4- way air flow and branch duct> Branch duct Air intake Air outlet + Close the outlet on the side of branch duct and air flows in 3 directions. <3- way air flow and branch duct> Branch duct Air intake Air outlet Air outlet closed position + The outlet on the side of branch duct and one of the other outlets are closed. Air flows in 2 directions. <2- way air flow and branch duct> Branch duct Air Air outlet outlet closed closed position position Air intake Air outlet closed position 78 PLA-RP71BA PLA-RP71BA2 4-way airflow (horizontal vane) Round duct 4-way airflow (horizontal vane) Rectangular duct 30 Duct Static pressure [Pa] Static pressure [Pa] 30 20 10 High Duct 20 10 High Low Low 0 0 0 2 4 6 Airflow rate [m3/min] 0 8 3-way airflow (horizontal vane) Round duct 2 80 70 70 Duct Duct 60 Close Static pressure [Pa] Static pressure [Pa] 60 50 40 30 Close 50 40 30 High 20 20 High Low 10 0 Low 10 2 4 6 8 Airflow rate [m3/min] 0 10 2-way airflow (horizontal vane) Round duct 0 100 90 90 Duct 2 Duct 80 Close Close 10 Close Close Static pressure [Pa] 70 60 50 40 30 High 20 4 6 8 Airflow rate [m3/min] 2-way airflow (horizontal vane) Rectangular duct 100 80 Static pressure [Pa] 8 3-way airflow (horizontal vane) Rectangular duct 80 0 4 6 Airflow rate [m3/min] 70 60 50 40 30 20 Low Low High 10 10 0 0 0 2 4 6 8 10 Airflow rate [m3/min] 0 12 2 4 6 8 10 Airflow rate [m3/min] • Use 1 of the 2 duct holes on the indoor unit. • Airflow rate of PLA-RP35~60BA can be calculated from the airflow rate based on the characteristic of the duct for PLA-RP71BA(2). • Use the optional air outlet shutter plate (PAC-SH51SP-E) for 3-way and 2-way airflow. 79 12 PLA-RP125BA PLA-RP125BA2 4-way airflow (horizontal vane) Round duct 4-way airflow (horizontal vane) Rectangular duct 30 30 Duct 20 Static pressure [Pa] Static pressure [Pa] Duct 10 10 0 0 0 2 4 Airflow rate [m3/min] 6 8 3-way airflow (horizontal vane) Round duct 0 2 4 Airflow rate [m3/min] 6 8 3-way airflow (horizontal vane) Rectangular duct 80 80 70 70 Duct Duct Close Close 60 Static pressure [Pa] 60 50 40 High 50 40 High 30 30 20 20 Low Low 10 10 0 0 0 2 4 6 Airflow rate [m3/min] 8 0 10 2-way airflow (horizontal vane) Round duct 2 4 6 Airflow rate [m3/min] 8 10 2-way airflow (horizontal vane) Rectangular duct 100 100 90 90 Duct 80 Duct 80 Close Close 70 70 60 60 Static pressure [Pa] Static pressure [Pa] High Low High Low Static pressure [Pa] 20 50 40 High 30 Close Close 50 High 40 Low 30 Low 20 20 10 10 0 0 0 2 4 6 8 Airflow rate [m3/min] 10 0 12 2 4 6 8 10 12 Airflow rate [m3/min] • Use 1 of the 2 duct holes on the indoor unit. • Airflow rate of PLA-RP100BA(3), PLA-RP140BA2 can be calculated from the airflow rate based on the characteristic of the duct for PLA-RP125BA(2). • Use the optional air outlet shutter plate (PAC-SH51SP-E) for 3-way and 2-way airflow. 80 9-3. PCA-RP·KA Fresh air intake amount & static pressure characteristics ■ PCA-RP60, 71KA PCA-RP50KA ■ 50 50 0 Static pressure[Pa] Static pressure[Pa] 0 -50 -100 -150 -200 -250 -300 -50 -100 -150 -200 -250 -300 0 1 2 3 0 4 1 Airflow rate[m³/min] ■ PCA-RP100, 125, 140KA A -50 Q -100 -150 Duct characteristics at site 2 C A -200 E -250 2 3 4 Q Airflow rate[m³/min] D 3 A 1 Q Qa 81 C 0 0 Static pressure[Pa] Curve in the graphs B 50 0 3 4 How to read curves 1 -300 2 Airflow rate[m³/min] Q…Designed amount of fresh air intake <m3/min> A…Static pressure loss of fresh air intake duct system with airflow amount Q <Pa> … B Forced static pressure at air conditioner inlet with airflow amount Q <Pa> C…Static pressure of booster fan with airflow amount Q <Pa> D…Static pressure loss increase amount of fresh air intake duct system for airflow amount Q <Pa> E…Static pressure of indoor unit with airflow amount Q <Pa> Qa … Estimated amount of fresh air 3 intake without D <m /min> 9-4. PEAD-RP·JA(L) Fan performance PEAD-RP35JA(L) (External static pressure 100Pa) 220-240V 50Hz PEAD-RP35JA(L) (External static pressure 35Pa) 220-240V 50Hz 120 60 110 Rated point 100 Limit External static pressure (Pa) External static pressure (Pa) 50 40 Rated point High 30 Middle 20 Low 10 Limit 90 High 80 70 Middle 60 50 Low 40 30 20 10 0 7 9 11 13 15 17 19 0 21 7 9 11 Airflow rate(m3/min) 13 PEAD-RP35JA(L) (External static pressure 50Pa) 220-240V 50Hz 17 19 21 PEAD-RP35JA(L) (External static pressure 150Pa) 220-240V 50Hz 70 170 160 Rated point 150 60 140 Limit External static pressure (Pa) External static pressure (Pa) 15 Airflow rate(m3/min) Rated point 50 High 40 Middle 30 Low 20 Limit 130 High 120 110 100 Middle 90 80 70 Low 60 50 40 30 10 20 10 0 7 9 11 13 15 17 19 0 21 Airflow rate(m3/min) 90 80 External static pressure (Pa) Rated point Limit High 60 50 Middle 40 Low 30 20 10 0 7 9 11 13 15 9 11 13 15 Airflow rate(m3/min) PEAD-RP35JA(L) (External static pressure 70Pa) 220-240V 50Hz 70 7 17 19 21 Airflow rate(m3/min) 82 17 19 21 PEAD-RP50JA(L) (External static pressure 100Pa) 220-240V 50Hz PEAD-RP50JA(L) (External static pressure 35Pa) 220-240V 50Hz 130 70 120 110 60 50 High 40 Rated point Middle 30 Low 20 Rated point Limit 100 External static pressure (Pa) External static pressure (Pa) Limit 90 High 80 70 Middle 60 50 Low 40 30 20 10 10 0 9 14 0 19 9 14 19 Airflow rate(m3/min) Airflow rate(m3/min) PEAD-RP50JA(L) (External static pressure 50Pa) 220-240V 50Hz PEAD-RP50JA(L) (External static pressure 150Pa) 220-240V 50Hz 180 80 170 160 70 External static pressure (Pa) External static pressure (Pa) Rated point 50 High 140 High 60 Middle 40 30 Rated point 150 Limit Low 20 Limit 130 120 110 Middle 100 90 80 Low 70 60 50 40 10 30 20 0 9 14 10 19 0 Airflow rate(m3/min) 9 14 Airflow rate(m3/min) PEAD-RP50JA(L) (External static pressure 70Pa) 220-240V 50Hz 100 90 External static pressure (Pa) 80 Limit Rated point 70 High 60 50 Middle 40 30 Low 20 10 0 9 14 19 Airflow rate(m3/min) 83 19 PEAD-RP60JA(L) (External static pressure 100Pa) 220-240V 50Hz PEAD-RP60JA(L) (External static pressure 35Pa) 220-240V 50Hz 120 60 110 50 Rated point 100 External static pressure (Pa) External static pressure (Pa) Limit 40 Rated point 30 High 20 Middle 90 Limit High 80 70 Middle 60 50 Low 40 30 Low 10 20 10 0 10 15 20 25 0 10 30 15 Airflow rate(m3/min) 20 PEAD-RP60JA(L) (External static pressure 50Pa) 220-240V 50Hz 170 160 Rated point 150 Limit 140 Rated point 50 External static pressure (Pa) External static pressure (Pa) 30 PEAD-RP60JA(L) (External static pressure 150Pa) 220-240V 50Hz 70 60 25 Airflow rate(m3/min) High 40 Middle 30 20 Low High 130 Limit 120 110 100 Middle 90 80 70 60 Low 50 40 30 10 20 10 0 10 15 20 25 0 30 Airflow rate(m3/min) 90 80 Rated point External static pressure (Pa) Limit High 60 50 Middle 40 30 Low 20 10 0 10 15 20 15 20 Airflow rate(m3/min) PEAD-RP60JA(L) (External static pressure 70Pa) 220-240V 50Hz 70 10 25 30 Airflow rate(m3/min) 84 25 30 PEAD-RP71JA(L) (External static pressure 100Pa) 220-240V 50Hz PEAD-RP71JA(L) (External static pressure 35Pa) 220-240V 50Hz 70 130 120 60 High 110 Rated point 50 External static pressure (Pa) External static pressure (Pa) 100 Limit High 40 Rated point 30 Middle 20 Low Limit 90 Middle 80 70 60 Low 50 40 30 10 20 10 0 10 15 20 25 0 30 10 15 Airflow rate(m3/min) 20 25 30 Airflow rate(m3/min) PEAD-RP71JA(L) (External static pressure 50Pa) 220-240V 50Hz PEAD-RP71JA(L) (External static pressure 150Pa) 220-240V 50Hz 90 180 170 High 160 80 Rated point 150 140 External static pressure (Pa) External static pressure (Pa) 70 Limit 60 High Rated point 50 Middle 40 30 Low 20 130 Middle Limit 120 110 100 90 80 Low 70 60 50 40 30 10 20 10 0 10 15 20 25 0 30 Airflow rate(m3/min) 100 90 High External static pressure (Pa) 80 Limit Rated point 70 Middle 50 40 Low 30 20 10 0 10 15 20 15 20 Airflow rate(m3/min) PEAD-RP71JA(L) (External static pressure 70Pa) 220-240V 50Hz 60 10 25 30 Airflow rate(m3/min) 85 25 30 PEAD-RP100JA(L) (External static pressure 100Pa) 220-240V 50Hz PEAD-RP100JA(L) (External static pressure 35Pa) 220-240V 50Hz 70 150 140 Limit 130 60 External static pressure (Pa) External static pressure (Pa) 120 50 40 Rated point 30 High Middle 20 Low High Limit 110 Rated point 100 90 Middle 80 70 Low 60 50 40 30 10 20 10 0 10 15 20 25 30 35 40 0 45 Airflow rate(m3/min) 90 External static pressure (Pa) External static pressure (Pa) Limit 70 High Rated point 50 Middle 40 Low 30 20 25 30 35 40 45 PEAD-RP100JA(L) (External static pressure 150Pa) 220-240V 50Hz 100 60 15 Airflow rate(m3/min) PEAD-RP100JA(L) (External static pressure 50Pa) 220-240V 50Hz 80 10 20 200 190 180 170 160 150 140 130 120 110 100 90 80 70 60 50 40 High Rated point Limit Middle Low 30 20 10 0 10 0 10 15 20 25 30 35 40 45 PEAD-RP100JA(L) (External static pressure 70Pa) 220-240V 50Hz 120 110 External static pressure (Pa) 100 Limit High 90 80 Rated point Middle 70 60 Low 50 40 30 20 10 0 10 15 20 25 30 35 40 10 15 20 25 30 Airflow rate(m3/min) Airflow rate(m3/min) 45 Airflow rate(m3/min) 86 35 40 45 PEAD-RP125JA(L) (External static pressure 100Pa) 220-240V 50Hz PEAD-RP125JA(L) (External static pressure 35Pa) 220-240V 50Hz 70 180 170 Limit 160 High 60 External static pressure (Pa) External static pressure (Pa) High 140 50 Low 40 Limit 150 Middle Rated point 30 20 130 120 110 100 90 80 Middle Rated point Low 70 60 50 40 30 10 20 10 0 15 20 25 30 35 40 0 45 15 20 Airflow rate(m3/min) 90 High External static pressure (Pa) External static pressure (Pa) Limit 70 Middle 50 Rated point Low 40 30 20 10 0 15 20 25 30 35 40 45 PEAD-RP125JA(L) (External static pressure 70Pa) 220-240V 50Hz 150 140 130 External static pressure (Pa) High Limit 110 100 90 Middle 80 70 Rated point Low 60 50 40 30 20 10 0 15 20 25 30 35 230 220 210 200 190 180 170 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 40 45 High Limit Middle Rated point Low 15 20 25 30 35 Airflow rate(m3/min) Airflow rate(m3/min) 120 35 PEAD-RP125JA(L) (External static pressure 150Pa) 220-240V 50Hz 100 60 30 Airflow rate(m3/min) PEAD-RP125JA(L) (External static pressure 50Pa) 220-240V 50Hz 80 25 40 45 Airflow rate(m3/min) 87 40 45 PEAD-RP140JA(L) (External static pressure 100Pa) 220-240V 50Hz PEAD-RP140JA(L) (External static pressure 35Pa) 220-240V 50Hz 70 190 180 170 160 150 Limit 60 50 External static pressure (Pa) External static pressure (Pa) High Middle 40 Low Rated point 30 20 High Limit 140 130 120 Middle 110 100 90 Rated point 80 70 60 50 Low 40 10 0 30 20 15 20 25 30 35 40 10 0 15 45 Airflow rate(m3/min) 90 High External static pressure (Pa) External static pressure (Pa) Limit Middle 60 Low 50 Rated point 40 30 20 10 0 15 20 25 30 35 40 45 50 Airflow rate(m3/min) 150 140 130 External static pressure (Pa) Limit 110 High 100 90 Middle 80 70 Rated point 60 Low 50 40 30 20 10 0 15 20 25 30 35 35 240 230 220 210 200 190 180 170 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 40 45 High Limit Middle 40 45 Airflow rate(m3/min) 88 Rated point Low 15 20 25 30 35 Airflow rate(m3/min) PEAD-RP140JA(L) (External static pressure 70Pa) 220-240V 50Hz 120 30 PEAD-RP140JA(L) (External static pressure 150Pa) 220-240V 50Hz 100 70 25 Airflow rate(m3/min) PEAD-RP140JA(L) (External static pressure 50Pa) 220-240V 50Hz 80 20 40 45 9-5. PEA-RP·GA Fan Performance Curve PEA-RP250GA Fan Performance Curve 50Hz PEA-RP200GA Fan Performance Curve 50Hz (Pa) (Pa) 250 300 External static pressure External static pressure 250 200 Hi 150 100 Lo 50 0 45.0 50.0 55.0 60.0 65.0 200 150 100 Lo 50 0 60.0 70.0 (CMM) Hi 65.0 70.0 75.0 Airflow 85.0 90.0 (CMM) PEA-RP500GA Fan Performance Curve 50Hz (Pa) 300 (Pa) 350 250 300 External static pressure External static pressure PEA-RP400GA Fan Performance Curve 50Hz 200 150 100 50 0 70.0 80.0 Airflow 250 200 150 100 50 80.0 90.0 100.0 110.0 120.0 130.0 (CMM) Airflow 0 100.0 110.0 120.0 130.0 140.0 Airflow 89 150.0 160.0 170.0 (CMM) NOISE CRITERION CURVES 10 10-1. INDOOR UNIT PLA-RP35BA NOTCH SPL(dB) High 31 Medium1 29 Medium2 28 Low 27 LINE PLA-RP50BA 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 10 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE 63 125 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 NC-20 250 500 1000 2000 4000 10 8000 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE 63 NC-20 125 250 BAND CENTER FREQUENCIES, Hz PLA-RP60BA NOTCH SPL(dB) High 32 Medium1 31 Medium2 29 Low 28 LINE PLA-RP71BA PLA-RP71BA2 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE 63 125 NC-20 250 500 1000 2000 4000 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) 1000 2000 4000 8000 NOTCH SPL(dB) High 34 Medium1 32 Medium2 30 Low 28 LINE 90 80 10 500 BAND CENTER FREQUENCIES, Hz 90 20 LINE 90 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) 90 NOTCH SPL(dB) High 32 Medium1 31 Medium2 29 Low 28 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 10 8000 BAND CENTER FREQUENCIES, Hz APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE 63 125 NC-20 250 500 1000 2000 BAND CENTER FREQUENCIES, Hz 90 4000 8000 PLA-RP100BA PLA-RP100BA3 NOTCH SPL(dB) High 40 Medium1 37 Medium2 34 Low 32 LINE PLA-RP125BA PLA-RP125BA2 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 10 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE 63 NC-20 125 250 500 1000 2000 4000 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 10 8000 BAND CENTER FREQUENCIES, Hz PLA-RP140BA2 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE 63 125 NC-20 250 500 1000 2000 4000 BAND CENTER FREQUENCIES, Hz NOTCH SPL(dB) High 44 Medium1 42 Medium2 39 Low 36 LINE OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) 90 UNIT 80 CEILING 70 NC-70 60 NC-60 1.5m 50 NC-50 40 NC-40 30 NC-30 20 10 LINE 90 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) 90 NOTCH SPL(dB) High 41 Medium1 39 Medium2 36 Low 34 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE 63 125 NC-20 250 500 1000 2000 4000 8000 BAND CENTER FREQUENCIES, Hz 91 MICROPHONE 8000 PEAD-RP·JA(L) Ceiling concealed 2m Aux.duct 1.5m 2m Measurement location Noise level at anechoic room (Low-Middle-High) Unit: dB(A) Model Exrernal static pressure 35Pa 50Pa 70Pa 100Pa 150Pa PEAD-RP35JA(L) 23-26-29 23-27-30 24-28-31 26-29-33 29-33-37 PEAD-RP50JA(L) 25-30-34 26-31-35 28-32-36 29-33-37 31-35-39 PEAD-RP60JA(L) 25-28-32 25-29-33 26-30-34 27-31-35 29-34-38 PEAD-RP71JA(L) 25-29-34 26-30-34 27-31-35 28-32-36 30-35-39 PEAD-RP100JA(L) 28-33-38 29-34-38 30-35-39 31-36-40 34-40-43 PEAD-RP125JA(L) 31-36-40 33-36-40 33-37-41 34-39-42 37-41-45 PEAD-RP140JA(L) 33-37-43 34-38-43 34-39-44 36-40-45 38-42-46 92 PEAD-RP35JA(L) External static pressure 35Pa 70 80 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) 80 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) External static pressure 100Pa High Middle Low NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Approximate minimum audible limit on continuous noise NC-20 10 0 63 125 250 500 1000 2000 4000 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Approximate minimum audible limit on continuous noise 63 BAND CENTER FREQUENCIES, Hz 70 NC-70 NC-60 50 NC-50 40 NC-40 30 NC-30 Approximate minimum audible limit on continuous noise NC-20 10 0 63 125 250 500 1000 2000 4000 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Approximate minimum audible limit on continuous noise NC-20 10 0 63 125 250 500 1000 2000 BAND CENTER FREQUENCIES, Hz 2000 4000 8000 4000 8000 93 High Middle Low NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Approximate minimum audible limit on continuous noise NC-20 10 63 125 250 500 1000 2000 BAND CENTER FREQUENCIES, Hz High Middle Low 80 1000 70 0 8000 BAND CENTER FREQUENCIES, Hz External static pressure 70Pa 500 80 60 20 250 External static pressure 150Pa OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) 80 125 BAND CENTER FREQUENCIES, Hz High Middle Low External static pressure 50Pa NC-20 10 0 8000 High Middle Low 4000 8000 PEAD-RP50JA(L) External static pressure 35Pa 70 80 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) 80 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) External static pressure 100Pa High Middle Low NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Approximate minimum audible limit on continuous noise NC-20 10 0 63 125 250 500 1000 2000 4000 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Approximate minimum audible limit on continuous noise 63 BAND CENTER FREQUENCIES, Hz 70 NC-70 NC-60 50 NC-50 40 NC-40 30 NC-30 Approximate minimum audible limit on continuous noise NC-20 10 0 63 125 250 500 1000 2000 4000 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Approximate minimum audible limit on continuous noise NC-20 10 0 63 125 250 500 1000 2000 BAND CENTER FREQUENCIES, Hz 2000 4000 8000 4000 8000 94 High Middle Low NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Approximate minimum audible limit on continuous noise NC-20 10 63 125 250 500 1000 2000 BAND CENTER FREQUENCIES, Hz High Middle Low 80 1000 70 0 8000 BAND CENTER FREQUENCIES, Hz External static pressure 70Pa 500 80 60 20 250 External static pressure 150Pa OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) 80 125 BAND CENTER FREQUENCIES, Hz High Middle Low External static pressure 50Pa NC-20 10 0 8000 High Middle Low 4000 8000 PEAD-RP60JA(L) External static pressure 35Pa 70 80 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) 80 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) External static pressure 100Pa High Middle Low NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Approximate minimum audible limit on continuous noise NC-20 10 0 63 125 250 500 1000 2000 4000 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Approximate minimum audible limit on continuous noise 63 BAND CENTER FREQUENCIES, Hz 70 NC-70 NC-60 50 NC-50 40 NC-40 30 NC-30 Approximate minimum audible limit on continuous noise NC-20 10 0 63 125 250 500 1000 2000 4000 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Approximate minimum audible limit on continuous noise NC-20 10 0 63 125 250 500 1000 2000 BAND CENTER FREQUENCIES, Hz 2000 4000 8000 4000 8000 95 High Middle Low NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Approximate minimum audible limit on continuous noise NC-20 10 63 125 250 500 1000 2000 BAND CENTER FREQUENCIES, Hz High Middle Low 80 1000 70 0 8000 BAND CENTER FREQUENCIES, Hz External static pressure 70Pa 500 80 60 20 250 External static pressure 150Pa OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) 80 125 BAND CENTER FREQUENCIES, Hz High Middle Low External static pressure 50Pa NC-20 10 0 8000 High Middle Low 4000 8000 PEAD-RP71JA(L) External static pressure 35Pa 70 80 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) 80 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) External static pressure 100Pa High Middle Low NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Approximate minimum audible limit on continuous noise NC-20 10 0 63 125 250 500 1000 2000 4000 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Approximate minimum audible limit on continuous noise 63 BAND CENTER FREQUENCIES, Hz 70 NC-70 NC-60 50 NC-50 40 NC-40 30 NC-30 Approximate minimum audible limit on continuous noise NC-20 10 0 63 125 250 500 1000 2000 4000 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Approximate minimum audible limit on continuous noise NC-20 10 0 63 125 250 500 1000 2000 BAND CENTER FREQUENCIES, Hz 2000 4000 8000 4000 8000 96 High Middle Low NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Approximate minimum audible limit on continuous noise NC-20 10 63 125 250 500 1000 2000 BAND CENTER FREQUENCIES, Hz High Middle Low 80 1000 70 0 8000 BAND CENTER FREQUENCIES, Hz External static pressure 70Pa 500 80 60 20 250 External static pressure 150Pa OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) 80 125 BAND CENTER FREQUENCIES, Hz High Middle Low External static pressure 50Pa NC-20 10 0 8000 High Middle Low 4000 8000 PEAD-RP100JA(L) External static pressure 35Pa 70 80 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) 80 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) External static pressure 100Pa High Middle Low NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Approximate minimum audible limit on continuous noise NC-20 10 0 63 125 250 500 1000 2000 4000 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Approximate minimum audible limit on continuous noise 63 BAND CENTER FREQUENCIES, Hz 70 NC-70 NC-60 50 NC-50 40 NC-40 30 NC-30 Approximate minimum audible limit on continuous noise NC-20 10 0 63 125 250 500 1000 2000 4000 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Approximate minimum audible limit on continuous noise NC-20 10 0 63 125 250 500 1000 2000 BAND CENTER FREQUENCIES, Hz 2000 4000 8000 4000 8000 97 High Middle Low NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Approximate minimum audible limit on continuous noise NC-20 10 63 125 250 500 1000 2000 BAND CENTER FREQUENCIES, Hz High Middle Low 80 1000 70 0 8000 BAND CENTER FREQUENCIES, Hz External static pressure 70Pa 500 80 60 20 250 External static pressure 150Pa OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) 80 125 BAND CENTER FREQUENCIES, Hz High Middle Low External static pressure 50Pa NC-20 10 0 8000 High Middle Low 4000 8000 PEAD-RP125JA(L) External static pressure 35Pa 70 80 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) 80 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) External static pressure 100Pa High Middle Low NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Approximate minimum audible limit on continuous noise NC-20 10 0 63 125 250 500 1000 2000 4000 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Approximate minimum audible limit on continuous noise 63 BAND CENTER FREQUENCIES, Hz 70 NC-70 NC-60 50 NC-50 40 NC-40 30 NC-30 Approximate minimum audible limit on continuous noise NC-20 10 0 63 125 250 500 1000 2000 4000 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Approximate minimum audible limit on continuous noise NC-20 10 0 63 125 250 500 1000 2000 BAND CENTER FREQUENCIES, Hz 2000 4000 8000 4000 8000 98 High Middle Low NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Approximate minimum audible limit on continuous noise NC-20 10 63 125 250 500 1000 2000 BAND CENTER FREQUENCIES, Hz High Middle Low 80 1000 70 0 8000 BAND CENTER FREQUENCIES, Hz External static pressure 70Pa 500 80 60 20 250 External static pressure 150Pa OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) 80 125 BAND CENTER FREQUENCIES, Hz High Middle Low External static pressure 50Pa NC-20 10 0 8000 High Middle Low 4000 8000 PEAD-RP140JA(L) External static pressure 35Pa 70 80 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) 80 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) External static pressure 100Pa High Middle Low NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Approximate minimum audible limit on continuous noise NC-20 10 0 63 125 250 500 1000 2000 4000 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Approximate minimum audible limit on continuous noise 63 BAND CENTER FREQUENCIES, Hz 70 NC-70 NC-60 50 NC-50 40 NC-40 30 NC-30 Approximate minimum audible limit on continuous noise NC-20 10 0 63 125 250 500 1000 2000 4000 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Approximate minimum audible limit on continuous noise NC-20 10 0 63 125 250 500 1000 2000 BAND CENTER FREQUENCIES, Hz 2000 4000 8000 4000 8000 99 High Middle Low NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 Approximate minimum audible limit on continuous noise NC-20 10 63 125 250 500 1000 2000 BAND CENTER FREQUENCIES, Hz High Middle Low 80 1000 70 0 8000 BAND CENTER FREQUENCIES, Hz External static pressure 70Pa 500 80 60 20 250 External static pressure 150Pa OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) 80 125 BAND CENTER FREQUENCIES, Hz High Middle Low External static pressure 50Pa NC-20 10 0 8000 High Middle Low 4000 8000 SOUND LEVELS Low-Middle-High Model Sound level dB (A) PKA-RP35, 50HAL 36 - 40 - 43 PKA-RP60, 71KAL 39 - 42 - 45 PKA-RP100KAL 41 - 45 - 49 PKA-RP35HAL PKA-RP50HAL PKA-RP60KAL PKA-RP71KAL External static pressure : 0Pa Power source : 220, 230, 240V, 50Hz 70.0 70.0 High Low 60.0 NC-60 55.0 50.0 NC-50 45.0 40.0 NC-40 35.0 30.0 20.0 NC-30 Approximate minimum audible limit on continuous noise NC-20 15.0 10.0 63 125 250 500 1k 2k Octave band center frequencies (Hz) 4k 8k 60.0 NC-60 55.0 50.0 NC-50 45.0 40.0 NC-40 35.0 30.0 NC-30 25.0 20.0 Approximate minimum audible limit on continuous noise 15.0 10.0 63 NC-20 125 250 500 1k 2k Octave band center frequencies (Hz) 4k 8k PKA-RP100KAL External static pressure : 0Pa Power source : 220, 230, 240V, 50Hz 70.0 UNIT WALL 1m 1m MICROPHONE High Low 65.0 Octave band pressure level (dB) 0dB=20μPa 25.0 High Low 65.0 Octave band pressure level (dB) 0dB=20μPa 65.0 Octave band pressure level (dB) 0dB=20μPa External static pressure : 0Pa Power source : 220, 230, 240V, 50Hz 60.0 NC-60 55.0 50.0 NC-50 45.0 40.0 NC-40 35.0 30.0 NC-30 25.0 20.0 Approximate minimum audible limit on continuous noise 15.0 10.0 63 125 250 NC-20 500 1k 2k Octave band center frequencies (Hz) 100 4k 8k PCA-RP50KA NOTCH SPL(dB) 40 High 37 Medium1 34 Medium2 32 Low PCA-RP60KA LINE 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE 63 125 NC-20 250 500 1000 2000 4000 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) 80 10 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE PCA-RP71KA NOTCH SPL(dB) High 41 Medium1 39 Medium2 37 Low 35 63 125 500 1000 2000 4000 NOTCH SPL(dB) High 43 Medium1 41 Medium2 39 Low 37 PCA-RP100KA LINE 8000 LINE 90 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE 63 125 NC-20 250 500 1000 2000 4000 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) 250 BAND CENTER FREQUENCIES, Hz 90 10 NC-20 10 8000 BAND CENTER FREQUENCIES, Hz 20 LINE 90 90 20 NOTCH SPL(dB) High 40 Medium1 37 Medium2 35 Low 33 80 70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 10 8000 NC-70 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE 63 125 NC-20 250 500 1000 2000 4000 BAND CENTER FREQUENCIES, Hz BAND CENTER FREQUENCIES, Hz 101 8000 PCA-RP125KA NOTCH SPL(dB) High 45 Medium1 43 Medium2 41 Low 39 PCA-RP140KA LINE 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE 63 125 NC-20 250 500 1000 2000 4000 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) 80 10 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 10 8000 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE 63 125 PCA-RP71HA NOTCH SPL(dB) High 38 Low 34 LINE 500 1000 2000 4000 8000 NOTCH SPL(dB) High 50 Low 44 LINE 90 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) 250 PCA-RP125HA 90 10 NC-20 BAND CENTER FREQUENCIES, Hz BAND CENTER FREQUENCIES, Hz 20 LINE 90 90 20 NOTCH SPL(dB) High 48 Medium1 45 Medium2 43 Low 41 80 70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 NC-20 10 63 125 250 500 1000 2000 4000 NC-70 8000 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE 63 125 500 ceiling 1m unit about 1.4m MICROPHONE 250 1000 2000 BAND CENTER FREQUENCIES, Hz BAND CENTER FREQUENCIES, Hz 1m NC-20 102 4000 8000 PSA-RP71GA NOTCH SPL(dB) 45 High 40 Low LINE PSA-RP100GA 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 10 APPROXIMATE THRESHOLD OF REARING FOR CONTINUOUS NOISE 63 125 80 70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 NC-20 250 500 1000 2000 4000 NC-70 APPROXIMATE THRESHOLD OF REARING FOR CONTINUOUS NOISE 10 8000 63 125 PSA-RP125GA NOTCH SPL(dB) High 51 Low 46 LINE 500 1000 2000 4000 8000 NOTCH SPL(dB) High 52 Low 47 LINE 90 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 APPROXIMATE THRESHOLD OF REARING FOR CONTINUOUS NOISE 63 125 NC-20 250 500 1000 2000 4000 8000 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) 250 PSA-RP140GA 90 10 NC-20 BAND CENTER FREQUENCIES, Hz BAND CENTER FREQUENCIES, Hz 20 LINE 90 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) 90 NOTCH SPL(dB) High 49 Low 44 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 APPROXIMATE THRESHOLD OF REARING FOR CONTINUOUS NOISE 20 10 63 BAND CENTER FREQUENCIES, Hz 125 NC-20 250 500 1000 2000 BAND CENTER FREQUENCIES, Hz unit MICROPHONE 1m 1m floor 103 4000 8000 10-2. OUTDOOR UNIT MICROPHONE 1m UNIT 1.5m GROUND MODE SPL(dB) COOLING 44 HEATING 46 90 LINE 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 10 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE 63 NC-20 125 250 500 1000 2000 4000 BAND CENTER FREQUENCIES, Hz PUHZ-RP100VKA PUHZ-RP100YKA MODE SPL(dB) COOLING 49 HEATING 51 LINE NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 10 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE 63 125 NC-20 250 500 PUHZ-RP125VKA PUHZ-RP125YKA 1000 2000 4000 8000 MODE SPL(dB) COOLING 50 HEATING 52 LINE 90 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE 63 125 NC-20 250 500 1000 2000 4000 8000 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) 70 BAND CENTER FREQUENCIES, Hz 80 10 LINE 80 8000 90 20 MODE SPL(dB) COOLING 47 HEATING 48 90 80 20 PUHZ-RP60VHA4 PUHZ-RP71VHA4 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) PUHZ-RP35VHA4 PUHZ-RP50VHA4 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 10 BAND CENTER FREQUENCIES, Hz APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE 63 125 NC-20 250 500 1000 2000 4000 BAND CENTER FREQUENCIES, Hz 104 8000 MODE COOLING HEATING SPL(dB) 50 52 LINE PUHZ-RP200YKA 90 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 10 MODE SPL(dB) COOLING 58 HEATING 59 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE 63 125 NC-20 250 500 1000 2000 4000 8000 BAND CENTER FREQUENCIES, Hz 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 10 APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE 63 125 NC-20 250 500 1000 2000 4000 BAND CENTER FREQUENCIES, Hz PUHZ-RP250YKA MODE SPL(dB) COOLING 58 HEATING 59 LINE OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) 90 80 70 NC-70 60 NC-60 50 NC-50 40 NC-40 30 NC-30 20 10 LINE 90 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB = 0.0002 μbar) PUHZ-RP140VKA PUHZ-RP140YKA APPROXIMATE THRESHOLD OF HEARING FOR CONTINUOUS NOISE 63 125 NC-20 250 500 1000 2000 4000 8000 BAND CENTER FREQUENCIES, Hz 105 8000 11 OPTIONAL PARTS 11-1. INDOOR UNIT Part Name Model Name Applicable model Remote sensor PAC-SE41TS-E All models Remote operation adapter Multiple remote controller adapter PAC-SF40RM-E PAC-SA88HA-E (1pc.) PAC-725AD (10pcs.) Remote on/off adapter Power supply terminal kit All models except PEA-RP400/ 500GA PAC-SE55RA-E L/N/Earth L/N PAC-SG96HR-E PCA-RP·KA, PSA-RP·GA PAC-SG94HR-E PKA-RP·HAL/KAL PAC-SH52HR-E PAC-SG97HR-E PLA-RP·BA/BA2/BA3 Decoration panel PLP-6BA Decoration panel with Wireless remote controller PLP-6BALM Decoration panel with Wired remote controller PLP-6BAMD Decoration panel with i-see sensor PLP-6BAE PCA-RP·HA PEAD-RP·JA(L) Decoration panel with i-see sensor, Wireless remote controller PLP-6BALME Decoration panel with i-see sensor, Wired remote controller PLP-6BAMDE Automatic filter elevation panel PLP-6BAJ i-see sensor corner panel PAC-SA1ME-E Wireless signal receiver PAR-SA9FA-E Space panel PAC-SH48AS-E Air outlet shutter plate PAC-SH51SP-E Multi-function casement PAC-SH53TM-E Flange for fresh air intake High-efficiency filter element (PAC-SH53TM-E is needed.) Wireless remote controller kit Drain pump PAC-SH65OF-E PAC-SH59KF-E High-efficiency filter Duct flange for fresh air Oil mist filter element (12pcs) Decoration cover (Front + Suspending bracket cover) Wired remote controller (with terminal bed) Drain pump Filter box PLA-RP·BA/BA2/BA3 PAR-SL94B-E PCA-RP·KA PAC-SH83DM-E PCA-RP50KA PAC-SH85DM-E PCA-RP60KA PAC-SH84DM-E PCA-RP71,100, 125, 140KA PAC-SH88KF-E PCA-RP50KA PAC-SH89KF-E PCA-RP60, 71KA PAC-SH90KF-E PAC-SF28OF-E PCA-RP100, 125, 140KA PCA-RP·HA PAC-SG38KF-E PAC-SF81KC-E PCA-RP71HA PAC-SF82KC-E PAR-21MAAT-E PCA-RP125HA PKA-RP·HAL PKA-RP·KAL PAC-SH75DM-E PKA-RP·HAL PAC-SH94DM-E PKA-RP·KAL PAC-KE92TB-E PEAD-RP35, 50JA(L) PAC-KE93TB-E PEAD-RP60, 71JA(L) PAC-KE94TB-E PEAD-RP100, 125JA(L) PAC-KE95TB-E PEAD-RP140JA(L) 106 11-2. OUTDOOR UNIT Part Name Model Name Applicable model M-NET adapter PAC-SF81MA-E PUHZ-RP35-250 A-control service tool PAC-SK52ST PUHZ-RP35-250 Drain socket PAC-SG61DS-E PUHZ-RP35-250 PAC-SG58SG-E PUHZ-RP35, 50 Air outlet guide (RP100-250 need 2 pieces.) Air protect guide (RP100-250 need 2 pieces.) Drain pan PAC-SG59SG-E PUHZ-RP60, 71 PAC-SH96SG-E PUHZ-RP100-250 PAC-SG56AG-E PUHZ-RP35, 50 PAC-SH63AG-E PUHZ-RP60, 71 PAC-SH95AG-E PUHZ-RP100-250 PAC-SG63DP-E PUHZ-RP35, 50 PAC-SG64DP-E PUHZ-RP60, 71 PAC-SH97DP-E PUHZ-RP100-250 PAC-SG81DR-E PUHZ-RP35, 50 Filter dryer ([6.35) ([9.52) PAC-SG82DR-E PUHZ-RP60-200 PAC-SG85DR-E PUHZ-RP250 Distribution pipe ([12.7) (Twin) MSDD-50TR-E PUHZ-RP71-140 MSDD-50WR-E PUHZ-RP200, 250 (Triple) MSDT-111R-E PUHZ-RP140-250 (Quadruple) MSDF-1111R-E PUHZ-RP200, 250 Joint pipe (Unit Extension pipe) ([15.88 [19.05) PAC-SG75RJ-E PUHZ-RP60-140 ([9.52 [12.7) PAC-SG73RJ-E PUHZ-RP60-200 ([12.7 [15.88) PAC-SG74RJ-E PUHZ-RP250 ([6.35 [9.52) PAC-SG72RJ-E PUHZ-RP35-50 107 TM HEAD OFFICE : TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN CCopyright 2009 MITSUBISHI ELECTRIC ENGINEERING CO., LTD. Distributed in Jul. 2009 No.OCS16 PDF 6 Made in Japan New publication, effective Jul. 2009 Specifications subject to change without notice.