Download Oblica Bathysca Focus Hublot
Transcript
bathyscafocus hublot: Installation and User Manual 1. Technical Data 2 2. PRE-Installation 3 3. INSTALLATION 5 4. Operation 13 5. efficiency and emissions test 14 6. installation clearance test 15 Keep for future use Oblica 200 Argyle St Fitzroy VIC 3065 03 9416 0400 1. Technical Data Weight and dimensions: Firebox diameter Firebox weight Flue diameter Flue weight Standard bracket weight External flue kit 700mm 68Kg 219mm 16Kg/meter 20Kg Triple skin 200/250/300mm Determined under test conditions: Nominal thermal output Efficiency 17.8kW 55,8% FLUE ø219 mm FIREBOX ø700 mm 500 mm oblica | bathyscafocus hublot Installation and User Manual page 2 2. Pre-INSTALLATION Congratulations on your purchase of the BathyscaFocus Hublot. This appliance should be installed and checked by a qualified professional. Ensure you have read the operation guidelines thoroughly prior to first use. For any questions or concerns please contact Oblica on 03 9416 0400. The installation process is outlined below: – Determine position of firebox and flue carefully observing the clearances described within this section – Install the suspension bracket – Install the external flue – Install the internal flue and engage the firebox – Ensure the floor has adequate protection Caution: Using components or parts other than those provided by the manufacturer or modifying the specification of components may result in inferior or unsafe operation. If such action is necessary, consult the manufacturer in the first instance. Warning: • The appliance and flue-system must be installed in accordance with AS/NZS 2918 and the relevant building code or codes. • Any modification of the appliance that has not been approved in writing by the testing authority will be in breach of the approval granted for compliance with AS/NZS 4013. • Once the flue has been installed and approved by a professional installer, the flue must not be modified in any way. oblica | bathyscafocus hublot Installation and User Manual page 3 2. Pre-INSTALLATION (CONTINUED) MINIMUM CLEARANCE – INTERNAL 2.1 Clearance from non-combustible surfaces (eg masonry) 2.3 Clearance from combustible surfaces (eg timber joist & plasterboard) 300mm minimum clearance is required from fully non-combustible surfaces. 1000mm minimum clearance is required on all sides when the BathyscaFocus Hublot can rotate 360˚ . Non Combustible Non Combustible Non Combustible 300 Combustible 750 Combus FIXED 300 2.2 Clearance from glass FULLY ROTATING 1000 1000 FULLY ROTATING 1000 750 Combustible Non Combustible FULLY ROTATING 300 Combust Combustible 300 FULLY ROTATING 1000 1000 Combustible Non Combustible FULLY ROTATING Non Combustible 300 300 Combustible Combustible (frameless or aluminium frame) Combustible 500 FULLY ROTATING 500 Combustible 750 FIXED Combustible FULLY ROTATING Combustible Non Combustible 1000 Glass (frameless or aluminium frame) Glass Glass (frameless (frameless or aluminium frame)or aluminium frame) FIXED Glass Glass clearance is 500mm minimum required from normal (frameless or aluminium frame) (frameless or aluminium frame) 750mm minimum clearance from the back and 1000 FULLY ROTATING non-combustible glass. 1000mm from the side is required if the rotation of the 500 500 350mm minimum clearance is required from BathyscaFocus Hublot is locked at 90˚ away from the toughened glass. wall. Locking the BathyscaFocus Hublot so that the opening is fixed is an option available on purchase. Glass 500 500 FULLY ROTATING FULLY ROTATING 1000 1000 Glass (frameless or aluminium fram IMPORTANT: Frames must also be considered. Timber window frames must be treated as combustible surfaces (see 2.3). Aluminium frames can be treated as non-combustible surfaces (see 2.2). oblica | bathyscafocus hublot Installation and User Manual Clearances may be reduced with the application of heat shielding to walls in accordance to the Australian Building Code. For information on heat shielding please contact our office on 03 9416 0400 or email info@oblica.com.au. page 4 3. InstallATION 3.1 Installing the suspension bracket • The bracket must be structurally secured within the roof as shown in the diagram below. • The largest cylinder must project down from the ceiling by at least 150mm (BCA requirement) unless the ceiling is made from a non-combustible material such as concrete. •You must leave a 25mm clearance gap between the bracket and the ceiling. This gap will be covered by the ceiling Flange. • 12mm ventilation gap between the plasterboard and the ceiling flange • 25mm minimum clearance from the triple skin flue to any combustible material within the roof space • 40mm minimum overlap of the stainless steel 8” flue into the connector Typical Flat ROOF INSTALLATION CHINAMAN HAT (Anti-Down-Draft device) TRIPLE SKIN FLUE 200 X 250 X 300 (8’ x 10’ x 12’) RUBBER FLASHING 250 Insulative pad 25 CROSS BAR SET IN-BETWEEN RAFTERS CEILING FLANGE 150 12 ( Plaster Ceiling Minimum Gap) 40 SUSPENSION BRACKET CONNECTOR LOWER FLUE 219mm dia. oblica | bathyscafocus hublot Installation and User Manual page 5 3. InstallATION (CONTINUED) 12 oblica | bathyscafocus hublot Installation and User Manual 150 25 Custom Length & Angle PITCHED ROOF INSTALLATION (Custom Made Bracket) page 6 3. InstallATION (CONTINUED) 3.2 Installing the external flue 1.Place the connection piece inside the suspension bracket. This will join the single skin flue below the bracket and the triple skin flue above the bracket which have different diameters. 2.Ensure the triple skin flue is installed as per Australian standards (see diagrams below). Pitched roof installation The top of the flue must be 400mm higher than the highest point of the roof. Alternatively, there must be a minimum distance of 8 meters from any higher section of roof. –> 40 cm –> 40 cm > –8m > 40 – cm –> 40 cm > –8m > 40 – cm –> 40 cm cm –> 120 Flat roof installation (less than 5˚ pitch) –> 120 cm > –8m > – 120 cm The top of the flue must be 1200mm above the roofline. Alternatively, there must be a minimum distance of 8 meters from any higher section of roof. –> 120 cm –> 120 cm oblica | bathyscafocus hublot Installation and User Manual > –8m > – 120 cm page 7 3. InstallATION (CONTINUED) 3.3 Installing the internal flue Position the single skin flue inside the suspension bracket and tighten the grab screws. Ensure that the flue is perfectly vertical and the grab screws are tight. 1 2 Grab Screw 3 oblica | bathyscafocus hublot Installation and User Manual 4 page 8 3. InstallATION (CONTINUED) 5 6 7 8 oblica | bathyscafocus hublot Installation and User Manual page 9 3. InstallATION (CONTINUED) 9 10 11 12 oblica | bathyscafocus hublot Installation and User Manual page 10 3. InstallATION (CONTINUED) 3.4 Protecting the floor •Any combustible floor beneath a fireplace must have a floor protector that extends 300mm beyond the diameter of the firebox in all directions. •If installed directly on combustible material, the floor protector must be made of a minimum 6mm thick cement sheet. Non-combustible finishes can be applied to the floor protector (tiles, steel sheet, light concrete, etc). • If the combustible floor is installed on concrete, you can replace the combustible material with noncombustible material laid directly onto the concrete. Floor protector laID on timber floor Combustible floor (eg. timber) Combustible floor (eg. timber) 300mm Insulative board (6mm) + non combustible finish Insulative board (6mm) + non combustible finish 300mm Combustible floor (eg. timber) Combustible floor (eg. timber) 300mm Non comb (eg.tiles) Non comb (eg.tiles) 300mm Joist Concrete Joist Concrete Floor protector laId on Joist Combustible floor (eg. timber) Combustible floor (eg. timber) FIREBOX FIREBOX 300mm Insulative board (6mm) + non combustible finish Insulative board (6mm) + non combustible finish 300mm Joist Joist oblica | bathyscafocus hublot Installation and User Manual page 11 300mm 300mm 3. InstallATION (CONTINUED) Floor protector lAID on CONCRETE Combustible 300mm Non combustible finish (eg.tiles) floor (eg.300mm timber) mbustible or (eg. timber) Non combustible finish (eg.tiles) Concrete Concrete TOP VIEW FIREBOX 300mm Floor protector / non combustible finish FIREBOX 300mm Combustible floor (eg. timber) Floor protector / non combustible finish Combustible floor (eg. timber) oblica | bathyscafocus hublot Installation and User Manual page 12 4. OPERATION 4.1 What you should burn • Untreated, air dried hardwood •Split logs with a humidity content of less than 20% 4.2 Do not burn • Trash • Painted plastic • Coated or preservative treated wood • Waste or black coal •Inflammable liquids • Fire gels •Moist wood with a residual humidity content of more than 20% (this may cause soothing of the chimney). IMPORTANT: •Misuse may lead to unhealthy and environmentally harmful emissions and will void any warranty or guarantee. • The maximum load capacity for the Bathyscafocus Hublot is 20kg of wood. • Burning only seasoned hardwood helps to protect the environment and lower emissions. For details of a wood supplier in your area please call our office on 03 9416 0400 or email info@oblica.com.au. Warning: • Do not use flammable liquids or aerosols to start or rekindle the fire. • Do not use flammable liquids or aerosols in the vicinity of the fireplace when operating. • Do not store fuel within prescribed installation clearance distances. • The use of some types of preservative-treated woods as a fuel can be hazardous. oblica | bathyscafocus hublot Installation and User Manual page 13 5. efficiency and emissions test TEST REPORT No 30A-13-0024-TRP-349704-0 TESTING LABORATORY: VIPAC Engineers and Scientists MANUFACTURER: Focus MODEL: Bathysca Porthole WORK REQUESTED: Assessment of appliance to AS/NZS 4012:1999 for determination of Power Output and Efficiency and AS/NZS 4013:1999 for Flue Gas Emission using hardwood fuel. issue DATE: 09/07/2014 INVESTIGATING OFFICERs: Christain Schmidt, Rebecca Searcy RESULTS: The appliance particulate emission factor established in testing is 1.2g/kg of dry wood, within the maximum specification of 4.0g/kg of dry wood. CONCLUSION: This appliance does comply with the requirements of AS/NZS 4013:1999 for the configuration tested. oblica | bathyscafocus hublot Installation and User Manual page 14 6. installation clearance test TEST REPORT No 30A-13-0024-TRP-349705-0 TESTING LABORATORY: VIPAC Engineers and Scientists MANUFACTURER: Focus MODEL: Bathysca Porthole WORK REQUESTED: Assessment of appliance in one configuration to AS/NZS 2918:2001 Appendix B, with a full length flue kit. issue DATE: 09/07/2014 INVESTIGATING OFFICERs: Christain Schmidt, Rebecca Searcy CONCLUSION: This appliance does comply with the requirements of AS/NZS 2918:2001 Appendix B for the configuration tested. oblica | bathyscafocus hublot Installation and User Manual page 15